JENNAIR L8V1A040U3VS High Altitude Conversion Kit Installation Guide

October 30, 2023
JENNAIR

JENNAIR-LOGO

JENNAIR L8V1A040U3VS High Altitude Conversion Kit

JENNAIR-L8V1A040U3VS-High-Altitude-Conversion-Kit-
PRODUCT

Product Information

The High Altitude Conversion Kit is designed for use with L8 natural gas furnace models only. The kit is intended for installations exceeding an altitude of 4000 feet above sea level. The kit is available in four different models: BAYHALTMOD0008, BAYHALTMOD0009, BAYHALTMOD0010, and BAYHALTMOD0011. The kit contents include an Installer’s Guide, PM tethers, conversion labels, and high altitude Personality Modules for L8V1A040U3VS, L8V1A060U3VS, L8V1B080U4VS, and L8V1C100U5VS models.

Product Usage Instructions

Before proceeding with the conversion, ensure that the gas supply is shut off and the electrical power is disconnected. Follow the steps below to install the High Altitude Conversion Kit:

Step 1: Check the Kit Contents

Check for damage to the kit contents and ensure that all items listed in Table 1 are present.

Step 2: Disconnect Electrical Supply to Furnace

Disconnect the electrical supply to the furnace.

Step 3: Remove Factory Shipped Personality Module

Cut the PM tether and remove the factory-shipped Personality Module. Discard it.

Step 4: Install the High Altitude Personality Module

Install the high altitude Personality Module and replace the tether.

Step 5: Reconnect Electrical Supply to Furnace

Reconnect the electrical supply to the furnace.
It is important to note that all phases of this installation must comply with national, state, and local codes. Additionally, this product can expose you to chemicals, including lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.p65Warnings.ca.gov.
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT – This document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.

WARNING

  • This conversion kit shall be installed by a qualified service agency in accordance with the furnace manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of the kit. The installation is not proper and complete until the operation of the converted furnace is checked as specified in the furnace manufacturer’s instructions supplied with the kit.

WARNING

  • This product can expose you to chemicals, including lead, which are known to the State of California to cause cancer and birth defects of other reproductive harm. For more information go to www.p65Warnings.ca.gov.

GENERAL

  • These high altitude conversion kits are to be used only with L8 natural gas furnace models only.
  • These instructions describe the conversion of these furnaces for installations exceeding an altitude of 4000 feet above sea level.
  • Due to the lower density of air at higher altitudes, there would be insufficient negative pressure developed by the induced draft blower to maintain normal operation. Therefore, to compensate for the less dense air, the Personality Module must be changed to prevent nuisance lockouts and/or cycling of the induced draft blower on high speed. Please note that with the reduced firing input rates required for high altitude installations, the induced draft blower has ample capacity to provide sufficient combustion air for proper and safe operation.
  • Refer to the National Fuel Gas Code – latest Edition 11.1.2 – High Altitude and Table E.1.1(d).

CAUTION

  • Before proceeding with the conversion, the gas supply must be shut off prior to disconnecting the electrical power.

CONVERSION

  • These instructions below apply to L8 gas furnaces only.
  1. Check for damage to kit contents, and check for all items listed in Table 1.
  2. Disconnect electrical supply to furnace.
  3. Cut PM tether and remove the factory shipped Personality Module and discard.
  4. Install the high altitude Personality Module and replace tether.
  5. Reconnect the electrical supply to the furnace.

CHECKOUT

  • Adjust input rate and manifold pressure according to the furnace Installer’s Guide. Install correct main burner gas orifice according to this document. Fill out the information on the conversion label (part number A343079P01) and attach the label to the exterior of the furnace door. Once the furnace has been correctly rated for the high altitude installation, the furnace installation shall be checked for proper installation and performance. Refer to the furnace Installer’s Guide for checkout procedure.

Table 1. Kit Contents

Part number Qty Description
18-CH107D1-1C-EN 1 Installer’s Guide
BAYHALTMOD0008 1 L8V1A040U3VS* PM
BAYHALTMOD0009 1 L8V1A060U3VS* PM
BAYHALTMOD0010 1 L8V1B080U4VS* PM
BAYHALTMOD0011 1 L8V1C100U5VS* PM
D154673P01 1 PM Tether
A343079P01 1 Conversion Label

About Trane and American Standard Heating and Air Conditioning

Trane and American Standard create comfortable, energy-efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are commit- ted to using environmentally conscious print practices.
18-CH107D1-1C-EN 31 May 2023 Supersedes 18-CH107D1-1B-EN (Mar 2022)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

JENNAIR User Manuals

Related Manuals