The Fresh-Aire UV Purity™ germicidal ultraviolet light and filtration system
offers the ultimate enhancement to indoor air quality. The system features
three unique echnologies (advanced filtration, germicidal UVC light, and
photocatalytic oxidation) that improve indoor air quality by actively reducing
airborne microbial contaminants and odor-causing volatile organic compounds.
The Purity™ unit is installed directly onto the return side of the air handler
or gas furnace.
WARNING
** PROTECT EYES FROM UV LIGHT TURN OFF THE UNIT OR DISCONNECT BEFORE
SERVICING
IMPORTANT!**
- Only qualified technicians should install this product*
- Install in accordance with relevant building codes
- Read instructions carefully including safety warnings
***** Installation of this product by anyone other than licensed HVAC or electrical contractors voids warranty.
Parts Included
A Purity™ Housing
B UV Reactive Filter Media
C Photocatalytic (PCO) Media with UVC Lamp
D Self-Tapping Screws x 11
E Spade Connectors (ST Models) x 3
F Tap-In Connectors (ER Models) x 2
System Installation
-
Before installing Purity™ remove the media guide rails (to access screw holes). Rails are held in place with plastic rivets.
-
Attach Purity™ housing to the air system cabinet using self-tapping screws as shown.
-
Replace rails using plastic rivets.
Power Supply
-
Remote-mounted power supplies (ER, ST/DT models) are typically mounted in the control box of the air system and are connected to 110-277 VAC (ST/DT) or wired to the 24 VAC transformer there (ER). Use a separate 24 VAC transformer if needed – see the warning.
24 VAC WARNING!
Systems with high 24 VAC loads may require the installation of a separate 24 VAC transformer to power the Purity™ system.
Always use a separate 24 VAC transformer with “communicating” air systems.
Draws 16 VA, may need to do load calculation: Volts under load X Amps under load. -
Internal power supplies (SP/DP models) are located inside the Purity™ housing and are attached to the back of the removable belly plate. Remove the belly plate to replace the power supply.
-
Power cables pass through a knockout hole on the side of the Purity™ housing. If access is limited pass the cables through the alternate knockout located on the other side.
IMPORTANT! Must be wired to constant power – do not connect to blower relay. -
Wiring
Insert Media
Insert media as shown. Be sure to orient the photocatalytic media so that the UV lamp faces the other filter not outward.
Interlock
To turn on the Purity™ system after installation close the access panel (which closes a spring-loaded interlock switch) and rotate the door latches to the closed position. Opening the access panel switches of the power system for system maintenance.
Replacing Media
Replace PCO Media (which includes the UVC light) every 2 years. Although the
UV light will still glow, after 2 years the germicidal effectiveness will fall
off. Replace with part # TUVLM-PRT.
The UV Reactive Filter Media should be changed every six months, however, it
may last up to a full year depending on local conditions. Replace with part #
TUV-RFM4-XXYY.
Trouble Shooting
Problem | Solution |
---|---|
UV Lamp(s) Not Lighting | 1. Check that power is applied. |
2. Ensure the remote lamp cables are properly connected.
3. Reset the power switch on the power supply (off then on).
4. Install New UV Lamp(s).
S. Consult Factory.
UV Lamp(s) Flickering| 1. UV Lamp(s) have reached the end of effective
service life. Install new lamp(s) of the same type.
2. If the unit is new, check remote cables to ensure they are properly
connected.
3. Reset the power switch on the power supply (off then on).
4. If new lamps still flicker, consult the factory.
UV lamps burned out prematurely| 1. Consult Factory.
New UV lamps will not light – power supply problem| 1. Consult Factory.
2. External power suppressor may be needed if power surges occur.
What Does This Warranty Cover?
– This lifetime limited manufacturer warranty covers any defects or malfunctions in material and workmanship under the normal use and service when operated and maintained in strict accordance with the manufacturer’s instructions for the Lifetime of the equipment.
How Long Does The Coverage Last? 1)
– Power Supply: For as long as you own the real property where the product is
installed. 2) TUVL-1XX Series Ultraviolet Lamp is warranted for germicidal
output for one year from the date of installation. 3)
TUVL-2XX Series Ultraviolet Lamp is warranted for germicidal output for two
(2) years from the date of installation. This warranty is not transferable.
What Will Triatomic Environmental, Inc. Do?****
– Triatomic Environmental, Inc. will replace any defective or malfunctioning part at no charge. You must pay any labor charges and shipping charges of a defective product to our warranty department.
What Does This Warranty Not Cover?****
– THIS PRODUCT IS NOT INTENDED TO BE PURCHASED AND INSTALLED BY UNLICENSED
HVAC OR ELECTRICAL CONTRACTORS.
– This warranty does not cover products or parts purchased from any source
other than licensed HVAC or electrical contractors.
– This warranty does not cover parts installed by unlicensed HVAC or
electrical contractors.
– This warranty does not cover parts damaged as a result of misuse, abuse, or
any use other than its intended use, accident, acts of god, neglect, or from
improper operation, maintenance, installation, modification, or adjustments.
– Triatomic Environmental, Inc. shall have no responsibility for charges
incurred by the customer for the installation or removal of warranted items.
– This warranty does not cover parts or equipment used with the Fresh-Aire UV
system that are not manufactured by Triatomic Environmental, Inc.
– **This warranty shall be void if UV lamps from manufacturers other than
Triatomic Environmental, Inc. are used with this equipment.
– Consequential and incidental damages are not recoverable under this
warranty.
– The manufacturer assumes no liability for any harm, which may occur as a
result of the use of the equipment herein and shall not be liable for
consequential or any other damages whether or not caused by the manufacturer’s
negligence or resulting from any express or implied warranty or breach
thereof.
– Consequential damages for the purpose of this warranty shall include, but
not be limited to, loss of use, income or profit, or loss of or damages to
property or injury or death to persons or animals occasioned by or arising out
of operation, use, the operation, installation, repair or replacement of the
equipment or otherwise.
– Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you.
– There are no warranties that extend beyond the description of the face
hereof.
How Do You Get Service?****
– In order to be eligible for service under this warranty, you MUST return the
warranty registration card or register online at
www.freshaireuv.com.
– If something is wrong with your product, call your installing contractor to
receive a Return Merchandise Authorization (RMA) and instructions for
returning the product to a licensed distributor in your area or the
manufacturer.
– Once the product is returned, we will inspect your product and contact you
within 10 business days of our receipt of the product to give the results of
our inspection.
– If we determine that the product is covered under this warranty, we will
ship it to you at no additional cost a replacement part. Replacement parts may
be refurbished.
– If we determine that the product is not covered under this warranty, or that
this warranty is void, the product will be returned to you COD. There is no
charge for inspection.
How Does State Law Apply?****
– This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Manufacturer’s Warranty:
This warranty supersedes and replaces any warranty statements orally made by the Sales Person, Distributor or Dealer or contained in the written instructions or other Brochures or informational documents in relation to this product. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State.
WWW.FRESHAIREUV.COM
TUVC-P-MAN 081721 © Fresh-Aire UV
DESIGNED & ASSEMBLED IN THE U.S.A
Optional 2nd Remote UV Light Installation Instructions
The optional Fresh-Aire Remote UV Light works with the Purity™ system for
enhanced disinfection, reduced system maintenance, and improved indoor air
quality.=
IMPORTANT!
- Purity™ Dual lamps are wired in series – both must be connected for lamps to light
- Only qualified technicians should install this product
- Install in accordance with relevant building codes
- Read instructions carefully including safety warnings
Installation Notes
Before installing the Fresh-Aire Remote UV Light it is necessary to determine
the optimal mounting location inside the air system. First, look for the area
with the heaviest mold growth. Also, consider a location that will allow the
germicidal UV light to shine on the greatest surface area.
Optional 2nd UV Light Parts
A UV Lamp 1 Year (TUVL-115P)
B UV Lamp 2 Year (TUVL-215P)
C Sight Glass
D “Z” Mounting Bracket
E Warning Sticker
Note: lamp A or B and parts C and D E are included with Purity™ Dual.
WARNING
PROTECT EYES FROM UV LIGHT TURN OFF THE UNIT OR DISCONNECT BEFORE SERVICING
Air Handler Interior Surface Installation
-
Determine the optimal position for placement of the UV lamp.
-
Use a utility knife to cut a slit in the insulation on the interior surface.
-
Place the magnetic “Z” bracket directly on the metal surface or remove the magnet and hard-mount the bracket using the self-tapping screws provided. Use foil tape to close the cut in the insulation.
-
Use plastic quick-nuts to attach the UV lamp to the “Z” bracket as shown.
-
Coil “A” plate or Duct Installation
1. Snap the “Z” bracket apart by bending.
2. Drill a 1” hole in the “A”-plate or duct then attach the smaller piece of the bracket using the self-tapping screws.
3. Insert the UV lamp into the hole then use the plastic quick-nuts to attach the UV lamp to the “Z” bracket as shown.
Remote UV Light Configuration
IMPORTANT! Only the Purity™ Dual model (with the ST Power Supply) has the
electrical capacity for the optional Remote UV Light. The cable for the reomte
lamp passes through the knockout on the left side of the Purity™ Housing. To
add a second UV light to an existing Purity™ system that is not a Dual model
install a separate Fresh-Aire UV AHU Series 1 or Blue-Tube UV system.
-
Remote UV Lamp Connection
1. When all the other components are properly installed connect the UV Lamp cable to the Purity™ power supply cable.
2. Make sure the flanges are aligned and then push the connectors firmly together. A tight connection ensures a proper water-resistant seal.
-
Sight Glass Installation
1. Find a suitable location on the outside of the ductwork near the UV Lamp installation and apply the Fresh-Aire UV® warning/lamp replacement sticker.
2. Drill a ½” hole through the orange circle on the sticker. Press the UV safety viewport into the hole.
3. Turn on the power and use the sight glass to confirm that the UV Lamp is operating. -
Lamp Replacement
The germicidal UV lamp in the Fresh-Aire Remote UV Light needs to be replaced periodically. A TUVL-115P lamp should be replaced every year. The TUVL-215P should be replaced every 2 years. Note: UV lamps will continue to emit visible light but lose germicidal effectiveness over time. You can upgrade to a 2-year lamp with your existing power supply.
CAUTION!
UV lamps contain small amounts of mercury – dispose of lamps in accordance
with local environmental regulations.
For more information
visitwww.lamprecycle.org
Note: Use of replacement UV lamps other than Fresh-Aire UV® voids
warranty.
Documents / Resources
|
FRESH-AIRE UV TUV-PRT-DP Purity Whole House Air Purifier
System
[pdf] Installation Guide
TUV-PRT-DP, Purity Whole House Air Purifier System, TUV-PRT-DP Purity Whole
House Air Purifier System
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>