GRIVEN GoboLED 80D Projection Spotlights User Manual

June 22, 2024
GRIVEN

GRIVEN GoboLED 80D Projection Spotlights

GRIVEN-GoboLED-80D-Projection-Spotlights

AL2502

 |
---|---
Weight| 8,7Kg (19.18 Lbs)
Housing| Iron/Alluminum, scratch resistant paint
IK rating| IK07
IP rating| IP65
Ambient temp.| -20°C to 40°C ( -4°F to104°F)
Power supply| 100-240 VAC 50/60Hz
Power| 100 W
Nominal current| 0,5A@230VAC
Power factor| cos. φ= 0,87
Thermal protection| Integrated electronic thermal protection management.
Electrical class| I
Cable| N.A.
Control| USITT DMX-512
Channels| 4
Color range| 1 High output LED 6500°K
Gobos| 1 rotating gobos (Ø53,3/40 mm)
Other features| linear 0-100% dimmer, strobe function, electronic blackout
Optics| 20° to 32° manual linear zoom and focus adjustment
Accessories| –

Dimensions

GRIVEN-GoboLED-80D-Projection-Spotlights-1

Important notices

  • This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.

  • Do not stare at the operating light source.

  • The fixture might be damaged by excess voltage. The installation of an overvoltage protection device on the electrical system may
    reduce the risk of damage.

  • The use of an adequate magnetothermic switch along the power supply line is recommended.

  • Connect the fixtures to each other only when disconnected from mains.

  • Never leave cables and connectors unconnected or unprotected for long periods.

  • Disconnect power before installing or servicing to avoid electrical shock.

  • Disconnect power before any connection operation.

  • Check voltage and frequency before powering the fixture. Do not exceed fixture specified voltage.

  • Do not handle the unit with wet hands or in wet environments.

  • Apply to qualified staff for any maintenance service not described in this instructions manual.

  • Do not exceed the maximum quantity of fixtures per line in order to avoid power surges.

  • Before powering the unit, ensure to use cables and connectors with proper section and length, according to its power consumption.

  • Prima di effettuare le connessioni verifi care la portata dei cavi / connettori e la lunghezza dei cavi tenendo conto dell’assorbimento del prodotto.

  • Fix the projector by using screws, hooks or other adequate supports that can bear its weight.

Connecting

WARNING! fixing and connecting operations must mandatorily be carried out by qualified personnel only !
WARNING! Ensure power supply is off before connecting or disconnecting fixtures !

GRIVEN-GoboLED-80D-Projection-Spotlights-2

*DMX cable type: 2×0.34 mmq impedance 110Ω, capacity 43pF/m, resistance 50Ω/Km.

GRIVEN-GoboLED-80D-Projection-Spotlights-3

  • Undo the 4 screws on the top of the cover to remove it.
  • Unscrew the cable glands by using an adequate hex key and remove the protective plugs.
  • Insert the power and signal cables and connect them to the terminals as shown below, then tight well all the cable glands in order to preserve the watertight.

GRIVEN-GoboLED-80D-Projection-Spotlights-4

Setup and Configuration

GRIVEN-GoboLED-80D-Projection-Spotlights-5

When all operations are finished, fix the cover on the fixture and tight well the 4 screws.

DMX MODE

GRIVEN-GoboLED-80D-Projection-Spotlights-6

WARNING Use a DMX repeater on each 32nd fixture of the daisy-chain or in case the total DMX cable lenght exceeds 300m ( 1000 ft.). Install a data terminator ( 120Ω) on the DMX out cable of the last unit of the daisy-chain as described in the DMX connection kit manual.

MASTER/SLAVE AUTOMATIC MODE

GRIVEN-GoboLED-80D-Projection-Spotlights-7

WARNING ! in this mode, no other DMX control device must be present along the line.

Fixing and beam aiming

GRIVEN-GoboLED-80D-Projection-Spotlights-8

GRIVEN-GoboLED-80D-Projection-Spotlights-9

DMX chart

DMX Mode 1

Chn.l Function Values
1 GOBO ROTATION 0~15
16~150 Rotation 0→100% clockwise
151~160 No rotation
161~255 Rotation 0→100% counterclockwise
2 INDEXING 0~7
8~248 360° gobo indexing
249~255 No effect
3 BLACKOUT DIMMER STROBO 0~15
16~150 Proportional 100→0% dimming
151~160 LED off
161~255 Strobe frequency 0→100%

DMX Mode 2

Chn.l Function Values

1

|

GOBO ROTATION

| 0~15| No rotation
16~150| Rotation 0→100% clockwise
151~160| No rotation
161~255| Rotation 0→100% counterclockwise

2

|

INDEXING

| 0~7| No effect
8~248| 360° gobo indexing
249~255| No effect

3

|

DIMMER

| 0~5| LED off
6~250| Proportional dimming
251~255| LED on 100%

4

|

STROBO

| 0~5| Strobe off
6~250| Strobe frequency 0→100%
251~255| Strobe frequency 100%

DMX Mode 3

Chn.l Function Values

1

|

BLACKOUT DIMMER STROBO

| 0~5| LED on 100%
16~150| Proportional 100→0% dimming
151~160| LED off
161~255| Strobe frequency 0→100%

DMX Mode 4

Chn.l Function Values

1

|

DIMMER

| 0~5| LED off
6~250| Proportional 100→0% dimming
251~255| LED on 100%

2

|

STROBO

| 0~5| Strobe off
6~250| Strobe frequency 0→100%
251~255| Strobe frequency 100%

Note :
In absence of DMX signal the LEDs will remain off with no gobo rotation.
In assenza di segnale DMX i LED rimarranno spenti e con nessuna rotazione gobo.

Zoom and Focus adjusting

GRIVEN-GoboLED-80D-Projection-Spotlights-10

Undo the 6 screws on the top of the cover to remove it.

GRIVEN-GoboLED-80D-Projection-Spotlights-11

  • Untighten the knobs, move the three lenses until the desired focus/beam angle has been achieved, then tighten the knobs.
  • When all operations are finished, fix the cover on the fixture and tight well the 6 screws.

Installing a gobo

GRIVEN-GoboLED-80D-Projection-Spotlights-12

Undo the 6 screws on the top of the cover to remove it.

GRIVEN-GoboLED-80D-Projection-Spotlights-13

  • Untighten the knobs, move sideways the three lenses.
  • Insert the gobo in the gear.

GRIVEN-GoboLED-80D-Projection-Spotlights-14

  • Insert the rubber gobo holder.
  • Block the gobo by deeply inserting the dedicated spring.
  • When all operations are finished, fix the cover on the fixture and tight well the 6 screws.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals