MUHLER APM-350UVS Air Purifier Instruction Manual
- June 12, 2024
- MUHLER
Table of Contents
APM-350UVS Air Purifier
Instruction Manual Model: APM-350UVS 55 W
220-240V/50-60Hz
Please read the instructions manual before using the appliance for the first time and save it for future reference.
READ AND SAVE THESE INSTRUCTIONS
WARNINGS: Failure to comply with the warnings listed below may result in
electric shock or serious injury.
This product should be used only in accordance with the specifications
outlined in this manual.
Usage other than what has been specified here may result in serious injury.
When using electrical appliances, basic precautions should always be followed
to reduce the risk of fire, electric shock and injury to persons, including
the following:
- Read all instructions before using appliance.
- IMPORTANT – This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
- To avoid fie or shock hazard, plug the appliance directly into a right AC electrical outlet.
- Keep the cord out of heavy traffic areas. To avoid fie hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters.
- To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
- Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the unit.
- Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
- NEVER drop or insert any object into any openings.
- DO NOT run cord under carpeting.
- DO NOT cover cord with throw rugs, runners, or similar coverings.
- DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Send to Customer Service for assistance.
- Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fie, electric shock or injury to persons.
- DO NOT use outdoors.
- DO NOT place anything on top of unit.
- NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
- DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
WARNING: To reduce the risk of fie or electric shock, do not use this fan
with any solid-state speed control device.
This appliance can be used by children aged from 12 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
PRODUCT STRUCTURE
AIR CLEANING SYSTEM
Improve your indoor air quality with your new Air Cleaning System. Multiple
levels of cleaning include a combination HEPA filter that captures allergens,
and Activated Carbon filter to remove odors.
PRE-FILTER: Captures initial dust and allergen particles.
ACTIVATED CARBON FILTER: Absorb formaldehyde, benzene and other noxious
gas.
HEPA FILTER: Captures dust, smoke, pollen and other allergens.
UV-C LIGHT: Destroys micro-organisms such as germs, viruses, bacteria and
fungi (such as mold toxins).
Ion: Negative ion improves the air quality by combining with dust or
reacting with odor molecules attached on the wall.
Plenty of negative ions exist in natural surroundings such as waterfalls or
forests. In this mode, negative ions bring the room air close to this natural
environment.
BEFORE OPERATING THE AIR PURIFIER:
-
Carefully remove your air purifier from box and plastic bag.
-
Select a firm, level and flat location for the air purifier.
• For proper air flow, locate the unit at least 1 foot from any wall or furniture.
• Make sure none of the grills are blocked. -
Before using, remove the filters then remove and discard bags.
-
Plug the power cord into a right voltage AC outlet.
IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.
OPERATING THE AIR PURIFIER
-
“POWER” BUTTON: Press this button to turn on or switch off the unit.
-
“AUTO” BUTTON: Press this button to turn on or switch off the auto mode, in auto mode, the AUTO indicator AUTO lit up on display, the unit adjusts fan speed according to the air quality automatically. If press Speed button , the AUTO mode quit, then speed adjustment is manual.
-
“SLEEP” BUTTON: By pressing this button the appliance will start running at low speed and the LED indicators will dim. Pressing any button disables the sleep mode.
ATTENTION: if the appliance is on both Sleep and Child Lock modes, pressing a button will disable only the Sleep mode (Child Lock mode will remain active). -
“SPEED” BUTTON: The fan speed of the unit can be adjusted when the unit is in operation (L/I M/II H/III TURBO/IV).
-
“UV-C” BUTTON: Press this button to turn on and off UV-C.
-
“TIMER” BUTTON: By pressing this button, the purifier can be timed to operate for intervals of 1h, 2h, 3h, 4h, 5h, 6h, 7h, 8h, 9h, 0h, stopping automatically when the selected operating time has elapsed.
SECONDARY MENU:
“Child Lock Mode/Dust Sensor Self-test/Filter Reset” BUTTON:
Press this button for 3-5 seconds to turn to secondary menu, include Child
Lock Mode/Dust Sensor Self-adjusting/Filter Reset function.
“Scrolling Display” BUTTON:
Press this button continuously, the display will show (Child Lock), (HEPA
Reset), (Dust Sensor Self- adjusting) in sequence. Press this button to choose
the requested mode.
“Confirm” BUTTON:
Press this button to confirm the mode chosen by “Scrolling Display”
button.
- Press to confirm to turn the model into Child lock mode, lit up on the display, press again to quit Child Lock mode.
Attention: Under Child Lock mode, pressing any button has no efficiency.
- When the words ”REPLACE FILTER” show on the screen, it is time to replace the filter. Replace the filter according to the directions and then press to confirm mode to RESET the filter. will stop flickering on the display.
- The SENSOR SELF TEST MODE is only used for manufacture internal calibration, in case of inaccuracy, user should not use this mode.
Attention: Under secondary menu, there are two ways to exit and return to initial menu interface:
- After confirmation of a selected mode the appliance automatically returns to the main menu.
- If no button is pressed under secondary menu for about 30 seconds the appliance automatically returns to the main menu.
Important note: When the unit is not in use, switch it off and unplug it.
DISPLAY
FAN SPEED INDICATOR
Fan speed indicator:
Noise levels: 32dB / 45dB / 55dB / 60dB
AIR QUALITY INDICATOR
Dirty(Red)
Bad (Orange)
Normal (Yellow)
Clean(Blue)
There are four different colors of the ring indicating four levels of air
quality
AIR QUALITY INDICATED BY DIFFERENT COLOR OF LIGHT RING.
Heavily Polluted | Red | (PM2.5: >150 μg/m³ ) |
---|---|---|
Lightly Polluted | Orange | (PM2.5: 100-149.9μg/m³) |
Moderate | Yellow | (PM2.5: 50-99.9μg/m³) |
Good | Blue | (PM2.5: 0-49.9μg/m³) |
FILTER REPLACE INDICATOR
The REPLACE FILTER indicator flickering continuously indicates that it is time
to replace the filter. Replace the filter according to the directions then to
confirm mode to RESET the filter under secondary menu to restart the system.
The indicator will stop flickering.
- Combination Filter will last approximately 6 months.
- Open the front cover from the top.
- Remove the combination filter by pull the two strips.
- Insert new Combination Filter into the unit. Consult the strips on the filter for correct installation direction.
- Reattach the extra Pre-filter to the Combination Filter.
- Reattach the front cover of the unit and securely latch into place.
CLEANING & MAINTAINING
THE COMBINATION FILTER
The air purifier should be cleaned at least once every month and the outer
Pre-/Activated Carbon Filter attached to the HEPA Filter should be cleaned
every month. More frequent cleaning may be required depending on environmental
conditions.
FILTERS
Clean with the brush attachment of your vacuum cleaner. This will remove lint
and dirt.
Combination filter (Pre-filter + Carbon + HEPA)
NOTE:
- Only the Extra Pre-filter is washable and make sure the pre-filter is dry when fix back the pre-filter to the combination filter.
- The Combination Filter is one filter system. The multiple layers include: the Pre-filter, Activated Carbon Filter and HEPA Filter.
MAINTENANCE CAUTION
Use a clean, dry, soft cloth to wipe the external surface of the unit.
NOTE: Do NOT stick any foreign objects or your fingers inside of the
unit.
CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on
and/or in the unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents.
MANUFACTURER AND IMPORTER:
Keten LTD.; VAT: BG123670208; fl. 7, 39 Vladimir Vazov blvd., 1836, Sofia,
Bulgaria
Phone: +359 2 8691023;
Fax: +359 2 8691025;
e-mail: sales@keten.bg
www.keten.bg
The symbol means that the product should not be disposed of with household waste in order to avoid environmental contamination and human injury. Take the appliance to a specialist recycling center for electrical appliances
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>