NEEWER Q-C TTL Wireless Trigger Instruction Manual

June 4, 2024
NEEWER

Q-C TTL Wireless Trigger

NEEWER logo

TTL Wireless Trigger

About This Manual
Thank you for purchasing the NEEWER® TTL Wireless Trigger.
The manual will cover the following:
the basic operating procedures and functions of the Wireless Trigger.
the application environment and safe use of the Wireless Trigger.
the installation of the accessories of the Wireless Trigger.

Package Contents

Upon receiving the package, please check whether all the products are included. if there are any missing or broken products, please contact Neewer Customer Service support@neewer.com).

Accessories

NEEWER Q C TTL Wireless Trigger - fig2

Compatible Device

Nomenclature

NEEWER Q C TTL Wireless Trigger - fig

You can press the Function 2 and Function 3 buttons together for three seconds to restore the trigger to default settings. ![NEEWER Q C TTL Wireless Trigger

Display

NEEWER Q C TTL Wireless Trigger - fig4

Power Supply Mode

Mode

| Exposure Compensation Setting
In this mode, the trigger can adjust the flash output between -3 and +3in 13 stop increments. At the level of 0, there will be no exposure compensation. Choose a specific group and rotate the Setting Dial to change the compensation level: -3.0, -2.7….0.0…..+2.7,+3.0…

Note: When the remote control sets an ID Number, the Q3 light Body ID must match the remote control (Note: Q3 Speedlite flash sold separately).

| Mode Switch
Choose one group (demo: Group A) and press” “the button to switch modes in the following order:
TTL>M—OFF.

I Group Display
When on a multiple group display, the trigger will switch to a single group display when you quickly press the” NEEWER Q C TTL Wireless Trigger -
iconNEEWER Q C TTL Wireless Trigger - icon” button. It will switch back to the multiple group display if you press the button again.
As a Transmitter or Receiver,
The trigger will work as a receiver when you press the” “button for three seconds until the symbol “NEEWER Q C TTL Wireless Trigger - iconNEEWER Q C
TTL Wireless Trigger - icon” appears on the display. It will turn into a transmitter if you press the button again for 3 seconds until the “T” letter shows on the display.

Restore Default Setting/High-Speed Sync
The trigger will restore to default settings when the Function 2 and Function 3 buttons are pressed together for three seconds. To activate the HSS function, please adjust to the main menu page and press the Function 2 button until the “ “symbol appears on the display.
I Modelling Lamp Control
When no specific group is chosen, the trigger can turn on/off all modeling lamps when you quickly press the “Function C button. When controlling a specific group of lights, please quickly press the “Function 4” button to change their light intensity from Level 1 to Level 6. (The modeling lamps within the group can all be turned off by pressing the Function 4 button for 3 seconds.) ** The light intensity level only fits that of Q5 TTL strobe light.
Channel/Test Flash
Press the “Function 1” button for 3 seconds. Then you can rotate the Setting Dial to choose a suitable channel.
**
The trigger can make a flashlight fire test flash when you press the” “button.
The trigger features 32 channels, available for the switch from Channel 01 to Channel 32. Please make sure that the transmitting and receiving devices are on the same channel.

Zoom Setting
Quick press the “Function 1” button. Then choose a specific group and rotate the Setting Dial to change zoom settings: auto/20/24/28/35/50/70/80/105/135/ 200mm. To exit the Zoom Setting page, please quick press the “Function 1” button again.
When the trigger is in receiving mode, ZOOM needs to be adjusted to AUTO.

Screen Lock Press the” ” button for 3 seconds until the word “LOCKED” appears on the display, which suggests that all buttons have been deactivated (except for the test flash button ” “). To unlock it, please press the ” ” button for 3 seconds until the word “LOCKED” disappears on the display.

Standby Mode
The trigger display will turn off If no operations are performed for 90 seconds. To activate the display, press any button on the trigger.
If mounted on the hot shoe of a camera, the trigger can be activated by pressing the camera’s shutter release button halfway.

Custom Settings Menu

Custom Symbol Function Option Description
STAY—T Standby Timer ON On
OFF Off
BY— R Standby Timer 30min will turn off when no operations are performed

for 30 minutes.
1H| will turn off when no operations are performed for 1. hour.
2H| will turn off when no operations are performed for 2 hours.
BEEP| Buzzer| ON| On
OFF| Off
LIGHT| Backlight Timer| 12sec| will turn off when no operations are performed for 12 seconds.
OFF| Always off
ON| Always on
SYNC| Sync Port| IN| fire Q3 flash
OUT| trigger signal input
LCD| LCD Contrast| -3-+3| between -3 and 3
ID| WIFI ID| OFF| Off
01-99| available from 01 to 99
DIST| Triggering distance| 0-30m| 0.30m triggering
1-100m| 1-100m triggering

Set-up Procedures

|
---|---
insert batteries in the battery compartment and latch the cover.| Attach the trigger hot shoe to your camera’s cold shoe. Then, turn the knob in the picture above clockwise until it is tightened.

**** Please heed the positive or negative polarity when inserting the batteries. If they are wrongly placed, the trigger wouldn’t turn on.

 Safety Notes

NEEWER Q C TTL Wireless Trigger - fig18

Please do not use the light in the rain or in a humid environment.| Please avoid using the product where it will be exposed to higher temperatures than 50 degrees Celsius.

Caution

  • Please don’t disassemble or modify the product unless professionally certified. Otherwise, there might be a risk of malfunction.
  • Please keep the product dry and avoid touching it with wet hands.
  • Please don’t use the trigger near flammable or explosive items.
  • Please avoid disposing of the battery in a fire or keeping it near the fire source.
  • Should there be a malfunction of the trigger, please turn it off immediately and try to identify the possible cause.
  • Please avoid using new and old batteries together or different types of batteries.
  • Please don’t short circuit or dismantle batteries

Maintenance

  •  A soft cloth is recommended to clean the trigger screen.
  • Please remove the batteries when the trigger is left unused for a long period of time.
  • The trigger should be kept in a dry and well-ventilated environment.
  • Please avoid using the trigger in close proximity to magnetic devices and strong electrostatic fields, such as radio transmitters, otherwise, the trigger might malfunction.

Product Specifications

Model Q-C Q-N Q-S
Signal Transmission Distance 0-100m
Built-in WIFI 2.4 GHz
Modulation MSK
Channel 32
WIFI ID 01-99
Group 5
2.5mm Sync Port A receiver device can control camera shooting with a 2.5mm

sync cable.
TX/RX| master/slave mode switch
Firmware Update| via the Type-C USB interface on the trigger
Power Supply| AA battery
Dimension| 1057564MM
Net Weight| about 120 grams

Q-S only supports single-contact flash, not TTL. Sorry for the inconvenience.NEEWER Q C TTL Wireless Trigger - qr
code

https://neewer.com/
http://cs.neewer.com
The actual product may differ from the picture in this manual in color and appearance.
www.neewer.com

Pantone:

|
---|---
| Cool Gray6c
| Cool Gray 8c
| 177C

2021.9.16

Documents / Resources

| NEEWER Q-C TTL Wireless Trigger [pdf] Instruction Manual
Q-C, TTL Wireless Trigger, Q-C TTL Wireless Trigger
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NEEWER User Manuals

Related Manuals