Danby DPA050B7BDB 3 In 1 Portable Air Conditioner Owner’s Manual
- June 12, 2024
- Danby
Table of Contents
PORTABLE AIR CONDITIONER
Owner’s Manual
MODEL
DPA053B4WDB
DPA070B4WDB
DPA050B7WDB
DPA050B7BDB
Welcome to the Danby family.
We are proud of our quality products and we believe in dependable service. We
suggest that you read this owner’s manual before plugging in your new
appliance as it contains important operation information, safety information,
troubleshooting, and maintenance tips to ensure the reliability and longevity
of your appliance.
You are entitled to the warranty coverage as described in the owner’s manual
provided with your new appliance.
- Please write down your appliance information below. You must keep the original proof of purchase receipt to validate and receive warranty services.
- Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION after fi lling out a product survey, at www.danby.com/support/product-registration/
Model Number: ____
Serial Number: ____
Date of Purchase: __
Need Help?
- Read your Owner’s Manual for installation help, troubleshooting, and maintenance assistance.
- Visit www.Danby.com to access self-service tools, FAQs and much more by searching your model number in the search bar.
- For the Quickest Customer Service, please fill out the web form at www.danby.com/support. Your submission will go directly to an expert on your particular appliance. Our average response times are between 20 minutes and 2 hours, during EST business hours.
- Call 1-800-263-2629 – please note that during peak hours, hold times can exceed one hour.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
| WARNING| Shows that the appliance uses a flammable refrigerant. If the
refrigerant leaks and is exposed to an external ignition source, there is a
risk of fire.
---|---|---
| CAUTION| Shows that the operation manual should be read carefully.
| CAUTION| Shows that service personnel should be handling this equipment with
reference to the installation manual.
| CAUTION| Shows that the information is available such as the operating
manual or the installation manual.
CAUTION: RISK OF FIRE
Flammable refrigerant used. When maintaining or disposing of the air
conditioner, the refrigerant must not be allowed to vent into the open air.
SAVE THESE INSTRUCTIONS!
SAFETY PRECAUTIONS
WARNING
- Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock or fire.
- Use only the included accessories and parts and specified tools for the installation. Using non-standard parts can cause water leakage, electrical shock, fi re, injury or property damage.
- Make sure that the outlet is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be found on the nameplate of the unit.
- The unit must be used in a properly grounded wall receptacle. If the wall receptacle is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse of circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the unit), have a qualified electrician install the proper receptacle.
- Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
- The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
- Do not modify the length of the power cord or use an extension cord to power the unit.
- Do not share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
- Do not install the unit in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
- Do not install the unit in a location that may be exposed to combustible gas as this could cause fire.
- The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects as this could cause tipping.
- Do not operate a unit that been dropped or damaged.
- Do not touch the unit with wet or damp hands or when barefoot.
- If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If the unit has been damaged contact a technician or customer service for assistance.
- In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
- The unit should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store the unit where it can fall or be pulled into water or any other liquid. Unplug immediately if this occurs.
- All wiring must be performed strictly in accordance with the wiring diagram location inside the unit.
- The units circuit board (PCB) is designed with a fuse to provide over current protection. The specifications of the fuse are printed on the circuit board.
- When the water drainage function is not in use keep the upper and lower drain plugs firmly installed in the unit. The drain plugs can be a choking hazard to children.
CAUTION
- This appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities may be different or reduced, or who lack experience or knowledge, unless such persons receive supervision or training to operate the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Children must be supervised around the unit at all times.
- If the power supply cord is damaged it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the power supply.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cords away from traffic and where it will not be tripped over.
- Do not operate a unit with a damaged power cord, plug, power fuse or circuit breaker. Discard the unit or return to an authorized service facility for examination and/or repair.
- To reduce the risk of fire or electric shock do not use this air conditioner with any solid-state speed control device.
- The appliance shall be installed in accordance with national wiring regulations.
- Contact the authorized service technician for repair or maintenance of this unit.
- Contact the authorized service installer for installation of this unit.
- Do not cover or obstruct the inlet or outlet grilles.
- Do not use this product for functions other than those described in this instruction manual.
- Before cleaning turn off the power and unplug the unit.
- Disconnect the power if strange sounds, smells or smoke comes from it.
- Do not press the buttons on the control panel with anything other than your fingers.
- Do not operate or stop the unit by inserting or pulling out the power cord plug.
- Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol, etc.
- Always transport the unit in a vertical position and stand on a stable, level surface during use.
- Always contact a qualified person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
- Hold the plug by the head of the power plug when removing it.
- Turn off the appliance when not in use.
Note about fluorinated gasses
- Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the C02 equivalent in tonnes of the fluorinated greenhouse gas on some models. Please refer to the relevant label on the unit itself.
- Installation, service, maintenance and repair of this unit must be performed by a certified technician.
- Product installation and recycling must be performed by a certified technician.
WARNING for using R32 refrigerant
- Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources for example, open flames, an operating gas appliance or an operating electric heater.
- Do not pierce or burn.
- Be aware that the refrigerants may not contain an odor.
- The appliance should be installed, operated and stored in a room with a floor area according to the amount of refrigerant to be charged. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself. When there are differences between the label and the manual on the minimum room area description, the description on the label shall prevail.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person involved with working on the refrigerant circuit should hold a current, valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
- Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- Please follow the instruction carefully to handle, install, clear and service the air conditioner to avoid any damage or hazard. Flammable refrigerant R32 is used within this air conditioner. When maintaining or disposing of the air conditioner the refrigerant must be recovered properly and should not be allowed to discharge to the air directly.
- No open fire or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used.
- Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
- Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard. For specific information on the type of gas and the amount, please to the relevant label on the unit itself.
- The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
Transport of equipment containing flammable refrigerants: See transport
regulations.
Marking of equipment using signs: See local regulations.
Disposal of equipment using flammable refrigerants: See national regulations.
Storage of equipment / appliances: The storage of equipment should be in
accordance with the manufacturer’s instructions.
Storage of packed (unsold) equipment: Storage package protection should be
constructed such that the mechanical damage to the equipment inside the
package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will
be determined by local regulations.
Information on servicing
-
Checks to the area: Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
-
Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapour being present while the work is being performed.
-
General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the work area have been made safe by removing all flammable material.
-
Checking for the presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed and intrinsically safe.
-
Presence of fire extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fi re extinguishing equipment shall be available to hand. Have a dry powder or C02 fire extinguisher adjacent to the work area.
-
No ignition sources: No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to risk of fire or explosion. All possible ignition sources including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure there are no flammable hazards or ignition risks. No smoking signs shall be displayed.
-
Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferable expel it externally into the atmosphere.
-
Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:
• The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
• The ventilation machinery and outlets are operating adequately and are not obstructed.
• If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
• Marking to the equipment continues to be visible and legible. Markings and signs that become illegible must be corrected.
• Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitable protected against being corroded. -
Checks to electrical devices: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include:
• That capacitors are discharged. This shall be done in a safe manner to avoid possibility of sparking.
• That no live electrical components and wiring are exposed while charging, recovering or purging the system.
• That there is continuity of earth bonding.
Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- To ensure that by working on electrical components the casing is not altered in such a way that the level of protection is affected, particular attention shall be paid to the following:
• Damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
• Ensure the apparatus is mounted securely.
• Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
Note: The use of silicon sealant may inhibit the effectiveness of some
types of leak detection equipment.
Intrinsically safe components do not have to be isolated prior to working on
them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit
without ensuring that this will not exceed the permissible voltage and current
permitted for the equipment in use. Intrinsically safe components are the only
types that can be worked on while live in the presence of a flammable
atmosphere. The test apparatus shall be at the correct rating. Replace
components only with parts specified by the manufacturer. Other parts may
result in the ignition of refrigerant in the atmosphere from a leak.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the
searching for or detection of refrigerant leaks. A halide torch or any other
detector using a naked flame shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for systems
containing flammable
refrigerants:
- Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not be adequate or may need recalibration. Detection equipment shall be calibrated in a refrigerant-free area. Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
- Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confirmed.
- Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper or pipe-work.
- If a leak is suspected, all naked flames shall be removed or extinguished.
- If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak.
Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other
purpose conventional procedures shall be used. However, it is important that
the best practice is followed since flammability is a consideration. The
following procedures shall be adhered to:
-
Remove refrigerant.
-
Purge the circuit with inert gas.
-
Evacuate.
-
Purge again with inert gas.
-
Open the circuit by cutting or brazing.
-
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times.
Compressed air or oxygen shall not be used for this task. -
Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere and finally pulling down to a vacuum.
This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital is brazing operations on the pipe-work are to take place. -
Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
Charging procedures
In addition to conventional charging procedures, the following requirements
shall be followed:
-
Ensure that contamination of different refrigerants does not occur when using charging equipment.
Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them. -
Cylinders shall be kept upright.
-
Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
-
Label the system when charging is complete, if not already labeled.
-
Extreme care shall be taken not to overfill the refrigeration system.
-
Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
Decommissioning
Before carrying out this procedure, it is essential that the technician is
completely familiar with the equipment in all its detail. It is recommended
good practice that all refrigerants are recovered safely. Prior to the task
being carried out, an oil and refrigerant sample shall be taken in case
analysis is required prior to re-use of reclaimed refrigerant. It is essential
that electrical power is available before the task is commenced.
A. Become familiar with the equipment and its operation.
B. Isolate system electrically.
C. Before attempting the procedure ensure that:
- Mechanical handling equipment is available if required for handling refrigerant cylinders.
- All personal protective equipment is available and being used correctly.
- The recovery process is supervised at all times by a competent person.
- Recovery equipment and cylinders conform to the appropriate standards.
D. Pump down refrigerant system, if possible.
E. If a vacuum is not possible, make a manifold so that refrigerant can be
removed from various parts of the system.
F. Make sure that cylinder is situated on the scales before recovery takes
place.
G. Start the recovery machine and operate in accordance with the
manufacturer’s instructions.
H. Do not overfill cylinders. No more than 80% volume liquid charge.
I. Do not exceed the maximum working pressure of the cylinder, even
temporarily.
J. When the cylinders have been filled correctly and the process is completed,
make sure that the cylinders and the equipment are removed from the site
promptly and all isolation valves on the equipment are closed off.
K. Recovered refrigerant shall not be charged into another refrigeration
system unless it has been cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been decommissioned and emptied
of refrigerant. The label shall be dated and signed. Ensure that there are
labels on the equipment stating the equipment contains flammable refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate
refrigerant recovers cylinders are employed. Ensure that the correct number of
cylinders for holding the total system charge are available. All cylinders to
be used are designed for the recovered refrigerant and labeled for that
refrigerant, i.e. special cylinders for the recovery of refrigerant. Cylinders
shall be complete with pressure relief valve and associated shut-off valves in
good working order. Empty recovery cylinders are evacuated and, if possible,
cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of
instructions concerning the equipment that is at hand and shall be suitable
for the recovery of flammable refrigerants. In addition, a set of calibrated
weighing scales shall be available and in good working order. Hoses shall be
complete with leak-free disconnect couplings and in good condition. Before
using the recovery machine, check that is it in satisfactory working order,
has been properly maintained and that any associated electrical components are
sealed to prevent ignition in the event of a refrigerant leak. Consult the
manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the
correct recovery cylinder and the relevant waste transfer note shall be
arranged. Do not mix refrigerants in recovery units and especially not in
cylinders. If compressors or compressor oils are to be removed, ensure that
they have been evacuated to an acceptable level to make certain that flammable
refrigerant does not remain within the lubricant. The evacuation process shall
be carried out prior to returning the compressor to the suppliers.
Only electric heating to the compressor body shall be employed to accelerate
this process. When oil is drained form a system, it shall be carried out
safely.
INSTALLATION INSTRUCTIONS
ACCESSORIES
- Air outlet adapter
- Exhaust hose
- Window slider adapter
- 2 Bolts
- Window slider A
- Window slider B and C
- Foam seal A (adhesive)
- Foam seal B (adhesive)
- Foam seal C (non-adhesive)
- Security bracket and 2 screws
- Drain hose
- Remote control and batteries
REQUIRED TOOLS
- Medium sized Phillips screwdriver
- Tape measure or ruler
- Knife or scissors
- Saw (in the event that the window sliders need to be cut to size)
ASSEMBLING THE WINDOW KIT
- Attach the air outlet adapter and the window slider adapter onto either end of the exhaust hose.
- Insert the air outlet adapter into the back of the appliance by placing over the air exhaust and then pushing in the direction of the arrow to lock into place.
- Measure the window opening where the window kit will be installed. Assemble as many sliders as necessary to fi t the window. If the length of the window requires all three sliders, use two bolts to fasten the sliders at the correct length. If the window opening is less that the minimum length of a single slider, use the slider that has the hole in it and cut it to the correct length. Make sure not to cut the end that has the hole as this is necessary to attach the exhaust hose adapter.
INSTALLING THE WINDOW KIT
The window kit can be used in either a hung window or a sliding window
application. The images at the right are for a hung window. The steps for a
sliding window are the same.
- Cut the adhesive foam seals A and B to the correct length for the window. Attach them to the window sash and frame as shown.
- Insert the assembled window slider kit into the window opening.
- Cut the non-adhesive foal seal C to match the width of the window. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room.
- Attach the window slider adapter to the hole in the window slider kit.
Note: It may be easier to attach the window slider adapter to the window
slider kit before placing the kit in the window.
Note: Do not over extend or bend the hose as this will impede air fl ow.
OPERATING INSTRUCTIONS
FEATURES
Front
- Handle (both sides)
- Control panel
Rear
- Upper air filter and air intake
- Air outlet
- Continuous drain outlet
- Lower air intake
- Drain outlet
- Casters
LOCATION
Place the air conditioner on a smooth, level floor that is strong enough to
support it and all included accessories.
Make sure the appliance is level to minimize noise and vibration.
The appliance must be installed near a grounded receptacle and the overflow
drain outlet on the rear of the appliance must be accessible.
Do not cover air inlets or outlets or the remote control receiver on the
control panel.
The appliance requires 30 cm (12 inches) of clearance on the sides and 50 cm
(20 inches) of clearance on the front.
The appliance requires at least 50 cm (20 inches) of clearance on the back.
-
Mode button:
• Press to select the desired mode.
• Press and hold for 3 seconds to activate the continuous fan. -
Cool mode indicator light: Illuminates when cooling mode is activated.
-
Fan mode indicator light: Illuminates when fan mode is activated.
-
Dry mode indicator light: Illuminates when dry mode is activated.
-
LED Display: Shows the set temperature in °C or °F or the auto-timer settings.
-
Power indicator light: Illuminates to indicate that the appliance has power.
-
Timer indicator light: Illuminates when the timer is activated.
-
Continuous fan indicator light: Illuminates when the continuous fan is activated.
-
Temperature control buttons:
• Used to set the temperature.
• Press and hold both temperature control buttons for 3 seconds to change the temperature display from °C to °F. -
Power Button: Press to turn the appliance on or off.
OPERATING MODES
Cool Mode
Choose cool mode to set the cooling function.
- Use the temperature control buttons to choose the desired temperature.
- Use the fan button to choose the desired fan speed.
- The temperature can be set within a range of 17 – 30°C (62 – 86°F).
- The exhaust hose should be installed during cool mode to ensure the best results.
Dry Mode
Choose dry mode to remove excess moisture from the air. Water will condense
inside the appliance and drain out the back.
- The humidity level and fan speed will be automatically set and cannot be modified in dry mode.
- The exhaust hose does not need to be installed during dry mode.
- It may be necessary to install the continuous drain hose during dry mode to remove excess water.
Fan Mode
Fan mode can be used to run the fan without engaging the cooling or
dehumidifying functions.
- Press the fan button to choose the desired fan speed.
- The exhaust hose does not need to be installed during fan mode.
- In cooling or dry mode, press and hold the mode button for 3 seconds to set the fan to run continuously. Press and hold the fan button for 3 seconds to disengage the continuous fan. During normal operation the fan will turn on and off with the compressor.
Auto Mode
Auto mode is a pre-set factory program that automatically defines the mode
(cool or fan) and fan speed based on the set temperature and the ambient
temperature. The exhaust hose should be installed during auto mode. Auto mode
can only be activated from the remote control.
TIMER
Auto Off
- When the air conditioner is turned on, press the timer button to activate the auto off timer.
- Press the temperature control buttons to change the set time in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours.
Auto On
- When the air conditioner is turned off, press the timer button to activate the auto on timer.
- Press the temperature control buttons to change the set time in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours.
Using Auto On and Auto Off Together
The auto on and auto off timers can be used at the same time by first setting
one and then the other. For example, if the air conditioner is running, you
can set the auto off timer to let it run for a set amount of time before
turning off and then set the auto on timer to turn it back on at a later time.
Or, if the air conditioner is not running, you can set the auto on timer to
turn it on at a later time and then set the auto off timer to shut it off
after running for a period of time.
Note: The timer will not cycle the air conditioner on and off
indefinitely. The auto on and auto off timers will function one time and then
the air conditioner will return to regular functioning.
Turning the air conditioner on or off at any time or changing the timer
setting to 0.0 will cancel the timer settings.
SHORTCUT FUNCTION
- Used to save a favourite setting.
- Set the appliance to the temperature and fan speed that you would like to set as a favourite.
- Press and hold the shortcut button for 2 seconds.
- Press the shortcut button at any point in future to return to the favourite setting.
- If no favourite is set, pressing the shortcut button will cause the appliance to run in auto mode at 29°C (79°F), with fan speed set to auto.
The shortcut function can only be activated with the remote control.
SLEEP FUNCTION
The sleep function can be used to conserve energy during sleeping hours. The
sleep function can only be used during cool mode.
When selected, the set temperature will increase by 1 degree per hour for 2
hours. The appliance will hold the new set temperature for 6 hours before
automatically returning to normal operation.
The sleep function can only be activated with the remote control and can be
canceled at any time by pressing the sleep button.
REMOTE CONTROL
-
Power button: Press to turn the appliance on or off.
-
Mode button: Press to select the desired mode.
-
Fan button: Press to select fan speed.
-
Sleep button: Press to start the sleep function.
-
LED button: Press to turn the LED display on or off.
-
Timer off button: Press to set the Auto-off timer.
-
Timer on button: Press to set the Auto-on timer.
-
Shortcut button: Press to set and activate the short cut function.
-
Temperature control buttons:
• Used to set the temperature.
• Press and hold both temperature control buttons for 3 seconds to change the temperature display from °C to °F. -
LED Display: Shows the set temperature in °C or °F or the auto-timer settings.
Note: The remote control can be used at a maximum distance of 8 meters (26 feet) from the appliance. Using the remote control more than 8 meters (26 feet) away from the appliance can result in poor reception of the signal.
REPLACING THE REMOTE BATTERIES
This air conditioner comes with two AAA batteries.
Place the batteries in the remote control before use.
- Slide the back cover from the remote downward to expose the battery compartment.
- Insert the batteries, ensure to match the (+) and (-) symbols on the ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
Notes:
- The air conditioner will not respond if curtains, doors or other materials block the signal from the remote control to the unit.
- Prevent any liquid from contact with the remote control. Do not expose the remote control to direct sunlight or heat.
- If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
- Do not mix old and new batteries or batteries of different types.
- Do not leave the batteries in the remote control if it is not going to be used for more than 2 months.
IMPORTANT
Do not dispose of batteries as unsorted municipal waste. Refer to local laws
for proper disposal of batteries.
REMOTE CONTROL REGULATIONS
This Class B digital apparatus complies with the Canadian CAN
ICES-003(B)/NMB-003(B) standard.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not approved by the party responsible for FCC and Industry Canada compliance could void the user’s authority to operate the equipment. This appliance complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
SUPPLIER’S DECLARATION OF CONFORMITY
47 CFR § 2.1077 Compliance Information
Unique Identifier: Danby, RG57H1(B)/BGCE-M
Responsible Party U.S. Contact Information:
Danby Products Inc.
1800 Production Drive
Findlay, OH
45840
Telephone number or internet contact information:
Danby.com
FCC Compliance Statement: This appliance complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
WATER DRAINAGE
Ensure the air conditioner is turned off and unplugged and that it is close to
a floor drain before setting up any drain option.
1. Drain Plug
When the internal drain pan becomes full the appliance will beep 8 times and
the digital display will show error code P1. The air conditioning or
dehumidifying action will stop but the fan may continue to operate.
Pull out the drain plug and allow the water to completely drain. Replace the
bottom drain plug, pressing firmly to ensure a tight fi t and no leaks.
The P1 error symbol will disappear and the appliance will resume regular
function once power is restored.
2. Continuous Drain
During dry mode, you may wish to install a continuous drain option so that the
air conditioner will automatically drain collected water.
Remove the upper drain plug and attach the drain hose that was provided with
the air conditioner.
Place the open end of the drain hose over the receptacle that it will drain
into; this could be a basement floor drain, a sink or similar.
Ensure that there are no kinks or bends in the drain hose and that it goes
straight down toward the floor.
The continuous drain is activated by gravity only.
If the hose is not positioned directly downwards, water will not drain
correctly.
CARE & MAINTENANCE
CLEANING
- Unplug the appliance before cleaning or servicing.
- Clean the cabinet with a lukewarm damp cloth and neutral detergent. Dry the cabinet with a lint-free dry cloth.
- Do not use gasoline, paint thinner or other chemicals to clean the appliance.
- Do not wash the appliance directly under a tap or using a hose. It may cause electrical damage.
AIR FILTER
The air filter should be cleaned every two weeks to ensure efficient
performance.
In households with animals, the air filters may need to be cleaned more often
and the external grills may need to be wiped to prevent blocked air fl ow.
LONG-TERM STORAGE
- Drain all water from the appliance.
- Run the appliance on Fan mode for half a day in a warm room to dry the inside of the appliance and prevent mold formation.
- Turn off the appliance and unplug it, wrap the cord and bundle it with tape.
- Remove the batteries from the remote control.
- Clean the air filters and reinstall them.
- Store the appliance in a cool, dark place.
Prolonged exposure to direct sunlight or extreme heat can shorten the lifespan of the appliance.
DISPOSAL
This appliance should not be treated as regular household waste. Check for
local regulatory compliance regarding the approved and safe disposal of this
appliance.
ERROR CODES
E1 – room temperature sensor error
E2 – evaporator temperature sensor error
E4 – display panel communication error
P1 – water tray is full – attach drain hose and drain excess water
FREQUENTLY ASKED QUESTIONS
Can I leave my air conditioner in place through the winter?
No, it is not recommended to leave the window kit in place during the winter.
What is the electrical rating?
This information can be found on the rating plate located on the side of the unit.
Can I use an extension cord?
No, an extension cord may not be used.
When should I use the exhaust hose?
The exhaust hose should be used in cool and auto modes. It is not required in fan and dry modes.
Can I extend the length of the exhaust hose?
No, extending the length of the exhaust hose can actually cause the air conditioner to run less effi ciently. Instead use an additional fan to blow the cool air to other locations.
When should I use the drain hose?
The drain hose can be attached to the continuous drain during dry mode.
Where do I drain water from?
There are two different drain options on this air conditioner, please refer to the water drainage section.
TROUBLESHOOTING
Air conditioner will not operate
- Plug is not fully inserted into the wall outlet.
- Blown fuse or circuit breaker.
Insufficient cooling
- Air filter is dirty.
- Blocked air flow.
- Appliance size is too small for application.
Noise
- The ground is not level.
- The air filter is dirty or blocked.
- Gurgling sounds are normal, this is coolant moving inside the appliance.
Odors
- Usually caused by the formation of mold or mildew on internal wet surfaces.
- Ensure the filter is clean.
- Run the air conditioner on fan mode to remove any internal moisture.
- Check for any blockages in the drain lines and ensure there are no obstructions.
- Place an algaecide tablet in the base pan; ensure the appliance is unplugged, remove the upper grille and filter, place the tablet in the middle water tray and replace the grille and filter
LIMITED “CARRY IN” WARRANTY
This quality product is warranted to be free from manufacturer’s defects in
material and workmanship, provided that the unit is used under the normal
operating conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally
sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.)
(hereafter “Danby”) or by an authorized distributor of Danby, and is non-
transferable.
This quality product is warranted to be free from manufacturer’s defects in
material and workmanship, provided that the unit is used under the normal
operating conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally
sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.)
(hereafter “Danby”) or by an authorized distributor of Danby, and is non-
transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date,
with no extensions provided.
First 24 months
During the first twenty four (24) months, any functional parts of this
product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the original purchaser.
To obtain service
Contact the dealer where the unit was purchased, or contact the nearest
authorized Danby service depot, where service must be performed by a qualified
service technician. If service is performed on the unit by anyone other than
an authorized service depot, all obligations of Danby under this warranty
shall be void.
It is the responsibility of the purchaser to transport the appliance to the
nearest authorized service depot.
Transportation charges to and from the service location are not protected by
this warranty and are the responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or
liable for any spoilage or damage to food or other contents of this appliance,
whether due to any defect of the appliance, or its use, whether proper or
improper.
EXCLUSIONS
Save as herein provided, by Danby, there are no other warranties, conditions,
representations or guarantees, express or implied, made or intended by Danby
or its authorized distributors and all other warranties, conditions,
representations or guarantees, including any warranties, conditions,
representations or guarantees under any Sale of Goods Act or like legislation
or statute is hereby expressly excluded. Save as herein provided, Danby shall
not be responsible for any damages to persons or property, including the unit
itself, howsoever caused or any consequential damages arising from the
malfunction of the unit and by the purchase of the unit, the purchaser does
hereby agree to indemnify and hold harmless Danby from any claim for damages
to persons or property caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage
or repair is caused by any of the following:
- Power failure.
- Damage in transit or when moving the appliance.
- Improper power supply such as low voltage, defective house wiring or inadequate fuses.
- Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions (ie. extremely high or low room temperature).
- Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
- Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
- Service calls resulting in customer education.
- Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled).
Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present the proof of purchase to our authorized service depot.
Warranty Service
Carry In
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: 519-837-0920 FAX:
519-837-0449
1-800-263-2629
1-800-263-2629
04/17
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: 419-425-8627 FAX:
419-425-8629
*Trademark of Danby Products
www.Danby.com
2023.01.11
Printed in China
References
- Danby® the Appliance Specialists | Canada
- Danby® the Appliance Specialists | Canada
- Danby® the Appliance Specialists | Canada
- Customer Support | Danby Canada
- Product Registration | Danby Canada
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>