SPECIFICATIONS
– Mifare Card Serial Number Reader
– Reads Mifare Classic, Ultralight and Desfire
Operating Voltage: | 9 to 14V DC |
---|---|
Current consumption: | Max. 130 mA |
Operating frequency: | 13,56 MHZ |
Read range: | Up to 6cm |
Reader Data Output: | Wiegand 26, 34, 42, 58, 24, 32, 40, 56 bit |
Cable distance: | 150m |
Backlight , Buzzer ON/OFF: | Yes |
Green LED: | Externally controlled |
Red LED: | Externally controlled |
Tamper protection: | When Opened or Dismantled |
Operating Temperatures: | -20°C to +60°C |
Protection standard: | IP65 |
Dimensions (mm): | 92L x 51W x 27H (ABS); |
Panel Connection: | Cable, 0.5 m |
MOUNTING
– The reader should not be mounted against metal surface. If there is an installation where the metal surface cannot be avoided, isolation base between the reader and the metal must be used. The thickness of the isolation base should be determined with test.
WIRING
Colour | Connection |
---|---|
Grey | Tamper |
Blue | Tamper |
Green | Led Green |
Orange | Led Red |
Black | GND |
Red | 12 VDC |
White | DO Wiegand |
Yellow | D1 Wiegand |
Tamper ; . | Tamper Switch |
--- | --- |
Tamper | Tamper Switch |
Led Green | Green Led |
Led Red | Red Led |
GND | ground |
12 VDC | 9-14 VDC |
DO /clock | Data 0 |
D1/Data | Data 1 |
WIEGAND CONNECTION
DIPSWITCH CONFIGURATION
Dipswitch | Function |
---|---|
1 | Backlight ON/OFF |
2 | Buzzer ON/OFF |
Convert
u I D| W 26bit| W 34bit| W 42bit| W 58bit| W 24bit| W 32bit| W 40bit| W 56bit
---|---|---|---|---|---|---|---|---
3| ON| YES| YES| NO| NO| NO| NO| NO| NO
3| OFF| NO| NO| NO| NO| NO| NO| NO| NO
Note: The conversion from 7byte ID to 4 byte ID is only possible with cards that have 7 byte ID Number. Those are: Mifare plus, Desfire and Ultralight.
Wiegand selection
Jumper | W 26bit | W 34bit | W 42bit | W 58bit | W 24bit | W 32bit | W 40bit | W 56bit |
---|---|---|---|---|---|---|---|---|
4 | Wiegand 1 | OFF | ON | OFF | ON | OFF | ON | OFF |
5 | Wiegand 2 | OFF | OFF | ON | ON | OFF | OFF | ON |
6 | No Parity | OFF | OFF | OFF | OFF | ON | ON | ON |
Default: Wiegand 26bit
Use the Dipswitchs no: 4, 5 and 6 to select the desired Wiegand Output
Note: All changes can be made live, without power cycling.
TRICOLOR LED
| Orange (Idle Mode): “LG-” and “LR-” not connected|
---|---|---
| Green: LG-(green wire) connected to GND|
| Red: LR-(orange wire) connected to GND|
| No light: LG-(green wire) and LR-(orange wire) connected to GND|
**** This product herewith complies with requirements of EMC directive
2014/30/EU, Radio Equipment Directive 2014/53/EU.
In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive
2015/863/EU.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>