xpr MTPADP-MHWO Multi-Technology RFID Keypads Installation Guide
- October 30, 2023
- xpr
Table of Contents
xpr MTPADP-MHWO Multi-Technology RFID Keypads
Product Specifications
The Multi-technology RFID Keypads are available in the following models: MTPADP-HO, MTPADP-HW, MTPADP-MW, MTPADP-MHW, MTPADP-MO, MTPADP-MWO, MTPADP- MHWO. These keypads utilize Keypad RFID technology with 125 KHz and 13.5 MHz frequency ranges. They have Wiegand Output and OSDP Interface, as well as RS-485 Output and support credentials such as EM4100, HID 125 KHz Compatible HID iClass CSN, Mifare CSN (Classic, Desfire, Plus, Ultralight), NTAG CSN ISO 15693 Encrypted DesFire* (EV1, EV2, EV3).
Technical characteristics include:
- Power Supply: 9 – 15 VDC
- Maximum current consumption @ 12 VDC: 150 mA
- Sound Indicator: Internal buzzer
- Led Indicators: Red, Green and Orange (Red + Green)
- Micro USB connector: Built-in for protocol selection, configuration and firmware update
- Environmental rating: Operating temperature: -20°C to +60°C;
- Operating humidity: 10% to 90% non-condensing
- Mounting Panel Connection: Terminal blocks and dipswitch
- Dimensions (H x W x D): 92 x 51 x 27 mm
Product Usage Instructions
To configure the Multi technology RFID Keypad:
- OSDP Configuration: Connect the RS-485 A (+) and RS-485 B (-) terminals. Input 1 is a dry contact to GND only. The tamper state is reported by RS-485. Use multiconductor cable with 2 twisted pair with shielding and a maximum length of 1200m.
- WS4 Configuration: Connect the RS-485 B (+) and RS-485 B (-) terminals. The readers for Doors 1.0 and 2.0 must be at address 0 and those for Doors 1.1 and 2.1 at address 1. For doors equipped with 2 readers, one must be at address 0 and the other at address 1. Use a multiconductor cable with 2 twisted pair with shielding and a maximum length of 80m.
- Wiegand Configuration: Connect the D0 and D1 terminals. Use untwisted, shielded, 0.22 mm2 min cable type, and for longer distance above 20m use a larger diameter.
- Custom RS-485 Configuration: Connect the RS-485 A (+) and RS-485 B (-) terminals. Use a multiconductor cable with 2 twisted pair with shielding and a maximum length of 1200m.
To set up OSDP configuration, reset SCBK by powering the reader and setting DIP switch 1 to ON, then setting it back to OFF position in less than 5 seconds. To set up WS4 configuration, ensure readers are set to the correct address (0 or 1) based on door location. The tamper state is reported by RS-485. DIP switch 2 sets RS-485 bus termination to either 120 ohm OFF or 120 ohm ON.
SPECIFICATIONS
Reference| MTPADP- MHWO| MTPADP- MW| MTPADP-
HW| MTPADP- HO| MTPADP- MHW| MTPADP- MO|
MTPADP- MWO
---|---|---|---|---|---|---|---
Technology|
Keypad| | | | | | |
RFID 125 KHz| | X| | | **| X| X
RFID 13.5 MHz| **| **| X| X| **| |
Interface|
Wiegand Output| | | **| X| **| X|
OSDP Interface| | X| X| **| X| **|
WS4 Interface| | X| X| **| X| **|
Customised RS-485 Output| | X| X| **| X| **| **
Supported credentials|
EM4100| **| X| | | **| X| X
HID 125 KHz Compatible| **| X| | | **| X| X
HID iClass CSN| **| **| X| X| **| |
Mifare CSN (Classic, Desfire, Plus, Ultralight), NTAG CSN| | | ****
X
| ****
X
| | |
ISO 15693| | **| X| X| **| |
Encrypted DesFire* (EV1, EV2, EV3)| | | X| X| |
| **
Technical characteristics**|
Power Supply| 9 – 15 VDC
Maximum current consumption @ 12 VDC| 150 mA| 150 mA| 65 mA| 65 mA| 150 mA|
150 mA| 150 mA
Sound Indicator| Internal buzzer
Led Indicators| Red, Green and Orange (Red + Green)
Micro USB connector| Built-in Micro USB connector for protocol selection,
configuration and firmware update
Environmental rating| Outdoor, IP65
Operating temperature| -30°C to +60°C
Operating humidity| 5% – 95% relative humidity, non-condensing
Mounting| Surface mount
Panel Connection| Terminal
Dimensions (H x W x D)| 92 x 51 x 27 mm
MOUNTING
MOUNTING
MOUNTING WITH MT-SPACER
FERRITE CORE MOUNTING
- Wrap the wires around the ferrite core (1 turn).
- The ferrite core is provided with the kit and it is used to reduce the EMI.
TERMINAL BLOCKS AND DIPSWITCH
TERMINALS
TERMINALS| DESCRIPTION| OSDP CONFIGURATION| WS4
CONFIGURATION| WIEGAND CONFIGURATION| CUSTOM RS-485
CONFIGURATION
---|---|---|---|---|---
A| RS-485 line| RS-485 A (+)| RS-485 B (+)| X| RS-485 A (+)
B| RS-485 line| RS-485 B (-)| RS-485 B (-)| X| RS-485 B (-)
D0| Output| X| X| D0| X
D1| Output| X| X| D1| X
LG| Input| Input 1
(Dry contact to GND only)
| X| Green LED input| Green LED input
LR| Input| Input 1
(Dry contact to GND only)
| X| Red LED input| Red LED input
BUZZ| Input| X| X| Buzzer input| Buzzer input
+12V| Power Supply| | | |
GND| Ground| | | |
T
|
Tamper
| X
(Tamper state is reported by RS-485)
| X
(Tamper state is reported by RS-485)
| |
T| Tamper| X| X| |
DIP SWITCH
DIP SWITCH| DESCRIPTION| OSDP CONFIGURATION| WS4
CONFIGURATION| WIEGAND CONFIGURATION| CUSTOM RS-485
CONFIGURATION
---|---|---|---|---|---
SW 1| Setup| SCBK Reset: Power the reader. Set DIP Switch 1 to ON and in the
less than 5 sec set it back to OFF position.| The readers for Doors 1.0 and
2.0 must be at address 0 and those for Doors 1.1 and 2.1 at address 1.
For doors equipped with 2 readers, one must be at address 0 and the other at address 1.
| X| X
SW 2| RS-485 120 OHM termination| | | X| ****
CABLING
CABLING| DESCRIPTION| OSDP CONFIGURATION| WS4
CONFIGURATION| WIEGAND CONFIGURATION| CUSTOM RS-485
CONFIGURATION
---|---|---|---|---|---
Max length| Cable Length| 1200m| 80m| 150m| 1200m
Cable
| ****
Recommended cable type
| ****
Multiconductor cable 2 twisted pair with shielding
| ****
Multiconductor cable 2 twisted pair with shielding
| Untwisted, shielded, 0.22 mm2 min. For longer distance above 20 m use larger diameter.| ****
Multiconductor cable 2 twisted pair with shielding
SIGNALISATION
SIGNALISATION| DESCRIPTION| OSDP CONFIGURATION| WS4
CONFIGURATION| WIEGAND CONFIGURATION| CUSTOM RS-485
CONFIGURATION
---|---|---|---|---|---
Reader ON-LIne
| Reader is in communication with the controller| ****
Managed by Controller
| ****
Managed by Controller
| Managed by Controller| Managed by Controller
Reader OFF-LIne
| Reader lost communication with controller| ****
Red LED Blinks
| ****
Red LED Blinks fast
| ****
X
| ****
X
SOFTWARE SETTINGS
XPR Toolbox is software for settings and firmware update of the reader. XPR Toolbox can be downloaded from a https://software.xprgroup.com/. To setup the reader or update the firmware, run the XPR Toolbox and select ”Generation 2” and the appropriate model, and click on “Open” tab. Follow the instruction in the software to set up or update firmware. Connect the reader to PC using Micro USB connector. No additional power for the reader is required. If the reader is used with EWS Controller, reader setting must be done by PROS-CS software.
ACCESSORIES (Optional)
-
MT-SPACER – Surface mounts spacer for the MINI range housing. It’s the perfect accessories to install easily your MINI range reader. It has six break-out openings for sheathed cabling. Smart and easy to install.
-
MC-MINI – Mini metal covers for the MINI Range.
- Metal protection Covers for Single MINI range readers.
- A304 brushed steel, compulsory cover for biometric MINI range for outside use.
-
USP – Optional single metal plate to fit single US electrical gang boxes. Also ideal for retrofit to cover pre-or old installation (small wall damages, chips, paint work, etc.) USP are supplied in the same color as the readers used for a blending aesthetic design.
Important: These accessories are not included with the readers!
This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.