xpr MTT-IR Infrared Touchless Switch User Manual

June 3, 2024
xpr

xpr MTT-IR Infrared Touchless Switch

SPECIFICATIONS

Input voltage: 12-24 VAC/DC;
Current consumption: max. 50mA
Sensor type: Infrared
Relay Output: 1A at 24V DC / 120V AC

Set relay time:

| 1, 3, 5, 10, 20, 30, 60 seconds or Toggle (ON/OFF) mode
Detection distance:| up to 6 cm
Detection distance

adjustment:

| Yes, by DIP switch
Indicators-LED:| Green, red, orange
LED control:| Yes, internal or external
Tamper:| Yes
Backlight ON/OFF:| Yes, by DIP switch
Buzzer ON/OFF:| Yes, by DIP switch
Operating Temperature:| -20o to 50°C
Operating Humidity:| Non-condensing up to 95%
Dimensions (mm):| 92L x 51W x 27H
Housing| ABS
Protection:| IP65

MOUNTING

xpr MTT-IR Infrared Touchless Switch fig 1

IMPORTANT NOTE:  The touch-free exit button is intended for indoor use. For outdoor use, it must be protected from direct rain / sleet / snow with the MC-MINI protective housing in order to avoid false triggering of the sensor.

TERMINAL BLOCKS AND DIP SWITCH

xpr MTT-IR Infrared Touchless Switch fig 2

  1. Relay time 1
  2. Relay time 2
  3. Relay time 3
  4. Buzzer ON/OFF
  5. Backlight ON/OFF / LED Control (ON-external, OFF-internal)
  6. Input Level (ON- Low, OFF-high)
  7. Detection distance adjustment (ON-6cm, OFF-2cm)
  8. Not used

WIRING

  • CONNECTION TO ACCESS CONTROL PANELxpr MTT-IR Infrared Touchless Switch fig 4
  • OUTPUT CONNECTION FOR DC DEVICE – FAIL OPENxpr MTT-IR Infrared Touchless Switch fig 5
  • OUTPUT CONNECTION FOR AC DEVICE – FAIL SECURExpr MTT-IR Infrared Touchless Switch fig 6

OPERATION

The device is activated with simple wave of a hand in front of the device.
The device will not be activated if the hand is not removed from the sensor within 3 seconds.

SET RELAY TIME

Relay Time DIP Switch 1 DIP Switch 2 DIP Switch 3

Toggle

(ON/OFF Mode)

| OFF| OFF| OFF
1 Second| ON| OFF| OFF
3 Seconds| OFF| ON| OFF
5 Seconds| ON| ON| OFF
10 Seconds| OFF| OFF| ON
20 Seconds| ON| OFF| ON
30 Seconds| OFF| ON| ON
60 Seconds| ON| ON| ON

  1. Relay time 1
  2. Relay time 2
  3. Relay time 3
  4. Buzzer ON/OFF
  5. Backlight ON/OFF / LED Control (ON-external, OFF-internal)
  6. Input Level (ON- Low, OFF-high)
  7. Detection distance adjustment (ON-5cm, OFF-2cm)
  8. Not used.

LED CONTROL

xpr MTT-IR Infrared Touchless Switch fig 11

  1. Input Level (ON- Low, OFF-high)
  2. Backlight ON/OFF / LED Control (ON-external, OFF-internal)

If switch 5 is OFF, then the control of the light is left to the device itself. If switch 5 is ON, then the LED light is controlled by the device where the LED terminals (LG, LR) are connected. Switch 6 defines the default state of the device, where the LED terminals (LG, LR) are connected. Default Low is GND and default high is 12V or open.

Example of externally controlled LED light, where the exit button’s light follows the reader’s light.

This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.

www.xprgroup.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

xpr User Manuals

Related Manuals