HER 1 BiSecur / HER 2 BiSecur receiver

HER 1 BiSecur Receiver

Dissemination as well as duplication of this document and the use and communication of its content are prohibited unless explicitly permitted. Noncompliance will result in damage compensation obligations. All rights reserved in the event of patent, utility model or design model registration. Subject to changes.

Dear Customer, We thank you for choosing a quality product from our company.

About these instructions

Read through all of the instructions carefully, as they contain important information about the product. Pay attention to and follow the instructions provided, particularly the safety instructions and warnings.
Further information about handling radio components can be found on the Internet.
Please keep these instructions in a safe place and make sure that they are available to all users at all times.

Safety Instructions

Intended use

The HER 1 BiSecur / HER 2 BiSecur receiver is a bi-directional receiver for the actuation of operators, controls and electric consumers. The HER 1 BiSecur receiver features a relay output. The HER 2 BiSecur receiver features two relay outputs. Both are operated by the BiSecur radio control.
Other types of application are prohibited. The manufacturer is not liable for damage caused by improper use or incorrect operation.

Safety instructions for operating the receiver

CAUTION
Danger of injuries due to unintended door travel
▶ See warning in section 9

ATTENTION
Functional impairment due to environmental influences
Non-compliance with these instructions can impair function!
Protect the receiver from the following conditions:

  • Direct sunlight (permissible ambient temperature: ­ 20°C to + 60°C)
  • Moisture
  • Dust

NOTES:

  • If there is no separate garage entrance, perform all programming changes and extensions of radio systems while standing in the garage.
  • After programming or extending the radio system, check the functions.
  • Only use original components when putting the radio system into service or extending it.
  • Local conditions may affect the useful range of the radio system!
  • When used at the same time, GSM 900 mobile phones can affect the range.

Scope of delivery

  • HER 1 BiSecur / HER 2 BiSecur receiver
  • Fixing material
  • External antenna (for HER 2 BiSecur)
  • Operating instructions

Description of the receiver

HER 1 BiSecur

HOERMANN HER 1 BiSecur Receiver - Description of the receiver
1

1. Receiver
2. Integrated antenna
3. Connecting terminal for 24 V DC / 24 – 230 V AC power supply
4. Connecting terminal of the relay output
5. Double DIL switch for receiver function| 6. Programming button P (P button)
7. PRG Programming button (PRG button)
8. LED red (RD) programming
9. LED, green (GN) feedback of the relay status
10. LED, blue (BU), radio
---|---

HER 2 BiSecur

HOERMANN HER 1 BiSecur Receiver - Description of the receiver
2

1. Receiver
2. External antenna
3. Connecting terminal for 24 V DC / 24 – 230 V AC power supply
4. Connecting terminal of the relay outputs
5. Quadruple DIL switch for receiver function
6. Programming button P (P button)| 7. PRG Programming button (PRG button)
8. LED red (RD) programming
9. LED, green (GN) feedback of the relay status
10. LED, blue (BU), radio
11. Connecting option for an external antenna
---|---

LED display

Blue (BU)
(Radio)

Condition Function
Illuminated briefly A valid radio code was discovered for channel 1
Illuminated briefly twice A valid radio code was discovered for channel 2

(only HER 2 BiSecur)
Flashes slowly| Receiver is in the learn mode for channel 1
Flashes 2 x| Receiver is in the learn mode for channel 2 (only HER 2 BiSecur)
Flashes quickly after slow flashing| A valid radio code was discovered during the learning
Flashes slowly for 5 seconds Flashes quickly for 2 seconds| Device reset is being implemented or completed
Off| operation mode

Red (RD)
(Programming)

Condition Function
Flashes slowly The impulse time is set to 5 seconds
Flashes 2 × The impulse time is set to 10 seconds
Flashes 3 × The impulse time is set to 15 seconds
Flashes 4 × The impulse time is set to 30 seconds
Flashes quickly Function changes are stored
Illuminated The function is set to 3-minute light that can be reduced

Green (GN)
(Feedback of the relay status)

Condition Function
Illuminated for the duration of the time in which the relay is activated
Button and DIL switch

P button| • Selection of the radio channel / relay
• Reset
---|---
PRG button| • Programming of the impulse times
• Switching of the 3-minute light function
• Reset of individual channels (only HER 2 BiSecur)
DIL switch (A / B)| Setting the function
(double or quadruple, depending on the type)

Fitting

Receiver
HOERMANN HER 1 BiSecur Receiver - Fitting 1

External antenna

NOTE:
By selecting an appropriate fitting location, the range can be optimised. The best alignment to achieve an optimum range must be established by trial and error.

Connection

The connecting cable from the receiver to the external antenna carries a safe low voltage and is tamper-proof, i.e. the manipulation of the cable or the external antenna does not lead to unintentional switching.
▶ Fit the receiver in an area that is protected against unauthorised access, as connection cables, e.g. for the garage door operator, are connected here.

HER 1 BiSecur

HOERMANN HER 1 BiSecur Receiver - Connection 1

HER 2 BiSecur

HOERMANN HER 1 BiSecur Receiver - Connection 2

Maximum contact load of the output relay (volt-free change-over contact):

Terminal  .6| Normally closed contact| Max. contact load:
2.5 A / 30 V DC
500 W / 250 V AC
---|---|---
Terminal  .8| Normally open contact
Terminal  .5| Shared contact

Switch functions of the receiver

HER 1 BiSecur

The HER 1 BiSecur receiver features a relay output.
The following functions can be set via the double DIL switch.

HER 2 BiSecur

The HER 2 BiSecur receiver features two relay outputs, which can be activated independently of each other.
The following functions can be set via the quadruple DIL switch for each relay output.

1 = Relay output 1
2 = Relay output 2

DIL Switch Functions

0 .5 second impulse

When a transmission impulse is received, the relay is activated for 0.5 seconds and then deactivated.

The relay is activated with the first transmission impulse and deactivated with the next.

The relay is activated for a period of 3 minutes after the first transmission impulse. The 3 minutes start again if another impulse is transmitted during this time. The relay is only deactivated if no further impulse is sent within the 3 minutes.

The reaction to a further radio signal can be changed via the PRG button. Upon delivery, the 3-minute light is set to can be extended, this setting can be changed so that the time can be reduced (see chapter 8). This means that if a further impulse is sent within those 3 minutes, the phase is ended prematurely and the relay is de-energised.
The set function only affects relay output 1 . Relay output 2 (only HER 2 BiSecur) is always set to extendable .

This function is intended for the use of the relay receivers in conjunction with electric openers. When a transmission impulse is received, the relay is activated for 3 seconds and then deactivated.

The impulse time can be changed via the PRG button (see chapter 8). At the delivery time, the time is set to 3 seconds.
The set time only affects relay output 1 . The time for relay output 2 (HER 2 BiSecur) is always set to 3 seconds fixed.

Resetting settings
▶ Set the DIL switches (A / B) to OFF .
The functions are reset to their status upon delivery.

Function of the P button .

The P button is used to select the radio channel / relay on which a radio code is to be taught in.

Function of the PRG button .

The PRG button is used to change the duration of the impulse and the reaction to a further radio signal of the 3-minute light function.

Changing the impulse duration / 3-minute light

  1. Set the DIL switches according to the function.

  2. Press and hold the PRG button.
    The red LED flashes slowly indicating the impulse time of 5 seconds.

  3. Briefly press the PRG button.
    The red LED flashes slowly twice, indicating the impulse time of 10 seconds.

  4. Briefly press the PRG button.
    The red LED flashes slowly 3 times, indicating the impulse time of 15 seconds.

  5. Briefly press the PRG button.
    The red LED flashes slowly 4 times, indicating the impulse time of 30 seconds.

  6. Briefly press the PRG button.
    The red LED is illuminated continuously indicating the set function of 3-minute light that can be reduced.

To save the change:
▶ Press and hold the PRG button until the red LED flashes quickly
The receiver automatically returns to the operation mode.

To abort the change without saving it:
▶ Press the PRG button frequently until the red LED goes out.
The receiver automatically returns to the operation mode.

Timeout:
If no button is pressed within 10 seconds, the receiver automatically returns to the operation mode.

Teaching in a radio code

CAUTION
Danger of injuries due to unintended door travel
Unintended door travel may occur while teaching in the radio code.
▶ Pay attention that no persons or objects are in the door’s area of travel when teaching in the radio code.

A maximum of 100 radio codes (HER 1 BiSecur) / 200 radio codes (HER 2 BiSecur) can be taught in the receiver. They can be distributed over the existing channels.
If the same function is taught in on two different channels, it will be stored in both channels (only HER 2 BiSecur).
In learn mode, the channels of the HER 2 BiSecur receiver can be switched by pushing the P button, as long as no radio code has been recognised.

To activate / switch a channel:
▶ Press the P button once, to activate channel 1.
▶ Press the P button 2 times, to activate channel 2 (only HER 2 BiSecur).

To abort the learn mode:
▶Press the P button 2 times (HER 1 BiSecur), or wait for the timeout.
▶ Press the P button 3 times (HER 2 BiSecur), or wait for the timeout.

Timeout:
If no valid radio code is recognised within 25 seconds, the receiver automatically returns to the operation mode.

Teaching in a radio code

HOERMANN HER 1 BiSecur Receiver - Teaching in a radio code
1

  1. Press the P button to activate the desired channel. ­
    • The blue LED will flash slowly for channel 1. ­
    • The blue LED will flash twice for channel 2 (only HER 2 BiSecur)

  2. Put the hand transmitter A, whose radio code is to be inherited, into the Inheriting / Transmitting mode.
    If a valid radio code is recognised, the LED flashes quickly in blue then goes out. The receiver is in the operation mode .

Operation

The receiver signals the recognition of a valid radio code by illuminating the blue LED. In addition, the green LED of the related relay is illuminated.

NOTE: If the radio code for the taught-in hand transmitter was copied from another hand transmitter, the hand transmitter button must be pressed a second time during initial start-up.
A valid radio code channel 1 is discovered = The blue LED is illuminated briefly once
A valid radio code channel 2 is discovered = The blue LED is illuminated briefly twice (only HER 2 BiSecur)

Switch function feedback

If a command for automatic feedback* is triggered by an HS 5 BiSecur hand transmitter or the BiSecur app, the receiver immediately reports the current status of the relay.

| Relay| HS 5 BiSecur
---|---|---
Switch function| Energised| LED: green
De-energised| LED: red
No feedback| | Communication error /
out of range

HS 5 BiSecur hand transmitter
If a radio code is taught in on two different channels (only HER 2 BiSecur), the status of the relay is primarily evaluated with the on/off switch function for the HS 5 BiSecur hand transmitter.
Possible feedback:

  1. If the on/off switch function has not been set.
    • At least one relay is energised  = LED: green
    • All relays are de-energised  = LED: red

  2. If the on/off switch function has been set on one relay output.
    • The switching relay is energised. = LED: green
    •  The switching relay is de-energised. = LED: red

  3. If the on/off switch function has been set on two relay outputs.
    • All of the switching relays are energised. = LED: green
    • At least one switching relay is de-energised. = LED: red

NOTE: The non-switching relay is not evaluated for feedback purposes.

BiSecur app
For feedback from the BiSecur app, please see the operating instructions for BiSecur Home (www.bisecur-home.com).

No feedback

There is a communication error if the HS 5 BiSecur hand transmitter or BiSecur app does not receive any feedback from the HER 1 BiSecur / HER 2 BiSecur receiver within a maximum of 5 seconds after the command.

  • The LED on the hand transmitter quickly flashes 4 × in orange. ­

  • The BiSecur app displays an appropriate message.
    See the operating instructions for BiSecur Home (www.bisecur- home.com).

  • ­ See the operating instructions for the HS 5 BiSecur hand transmitter, automatic feedback of the door position.

Reset

Complete reset

All radio codes are deleted by the following steps:

  1. Switch the activated relay off.

  2. Press and hold the P button.
    •­ The blue LED flashes slowly for 5 seconds. ­
    • The blue LED flashes rapidly for 2 seconds.

  3. Release the P button.
    All radio codes have been deleted .

NOTE: If the P button is released prematurely, the device reset will be aborted and the radio codes are not deleted.

Resetting individual channels

(only HER 2 BiSecur)
All radio codes of individual channels are deleted by the following steps:

  1. Switch the activated relay off.

  2. Press the P button to activate the desired channel.
    •­ The blue LED will flash slowly for channel 1. ­
    • The blue LED will flash twice for channel 2.

  3. Press and hold the PRG button.
    •­ The blue LED flashes slowly for 5 seconds. ­
    • The blue LED flashes rapidly for 2 seconds.

  4. Release the PRG button.
    All radio codes of the selected channel have been deleted .
    The receiver automatically returns to the operation mode.

NOTE: If the PRG button is released prematurely, the reset of individual channels will be aborted and the radio codes are not deleted.

Disposal

| Dispose of the packaging sorted by materials.
---|---
| Electrical and electronic devices must be returned to the appropriate recycling facilities.
| Dispose of the batteries separately. Each consumer is legally required to leave batteries with a collection point in their community, their district, or with a trader.

Technical data

HER 1 BiSecur / HER 2 BiSecur receiver

Model| HER1-868-BS
HER2-868-BS
---|---
Frequency| 868 MHz
Transmitting power (EIRP)| max. 20 mW
Power supply| 24 V DC / 24 − 230 V AC
Perm. ambient temperature| −20 °C to +60 °C
max. humidity| 93 % non-condensing
Protection category| IP 65
Relay capacity| max. 500 W / 250 V AC; 2,5 A / 30 V DC
Dimensions (W × H × D)| 150 × 70 × 55 mm

EU and UK Declaration of Conformity

Hörmann KG Verkaufsgesellschaft and Hörmann UK Ltd. herewith declares that the radio equipment type HER 1 BiSecur / HER 2 BiSecur receiver complies with the EU Directive 2014/53/EU and the UK Regulations 2017 No. 1206.
The complete text of the EU Declaration of Conformity and of the UK Declaration of Conformity can be found on the following website:

www.hoermann-docs.com/279226

HER 1 BiSecur / HER 2 BiSecur
Hörmann KG Verkaufsgesellschaft
Upheider Weg 94-98
33803 Steinhagen
Deutschland

4581522 B4

Documents / Resources

| HOERMANN HER 1 BiSecur Receiver [pdf] Instruction Manual
HER 1 BiSecur Receiver, HER 1, BiSecur Receiver, Receiver
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals