- Leaking LP-gas can cause fire or explosion, leading to serious bodily injury or death. It is important to take necessary precautions when using the gas fire pit. If you detect any leaking LP-gas, immediately evacuate everyone from the area and contact the Fire Department. Do not attempt to repair the issue yourself.
- Do not use or store the gas cylinder in a building, garage, or enclosed area.
- Keep children away from the gas cylinder and make sure they do not tamper with it.
- When not in use, keep the cylinder valve turned off. Self-contained appliances should only be used with a cylinder of 30 lb capacity or less.
- Avoid exposing the cylinder to high temperatures. Read and follow the manufacturer’s instructions for safe usage.
- Consult the manufacturer’s instructions for proper cylinder connection.
- Make sure the regulator vent is not pointing upwards. Do not check for gas leaks with a match or open flame. Use soapy water at marked areas to detect leaks.
- Before lighting the appliance, ensure that there are no gas leaks from the valves and connections. When transporting the gas cylinder, keep it secured in an upright position with the cylinder valve turned off.
- Do not store a spare LP cylinder under or near a barbecue grill or any heat sources.
- Never fill an LP cylinder beyond 80% full to avoid fire hazards.
Pre-Assembly
Before assembling the gas fire pit, please ensure that you have all the
necessary components and tools. Refer to the package contents section for
details.
Package Contents
The package should include all the components required for assembly. Please
check that you have the following items:
- List of components (as mentioned in the assembly instructions)
- Screws and other small parts
Assembly
Follow the assembly instructions provided in pages 7-10 of the user manual
to properly assemble the 32 Inch Gas Fire Pit.
Operating Instructions
Once the gas fire pit is assembled, follow the operating instructions
provided in pages 11-13 of the user manual to safely use the product.
Maintenance
Refer to page 14 of the user manual for maintenance instructions to keep
the gas fire pit in good working condition.
If you have any further questions or need assistance, please contact our
Customer Service Team at
customercare@yimohome.com.
ITEM NO. GYM-80004
Assembly Instructions
32 Inch Gas Fire Pit
R
C
US
DANGER · FLAMMABLE GAS UNDER PRESSURE.
LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED CAUSING SERIOUS BODILY
INJURY OR DEATH.
CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF THIS CYLINDER OR UNUSED
LP-GAS.
WARNING · FOR OUTDOOR USE ONLY.*
DO NOT USE OR STORE CYLINDER IN A BUILDING, GARAGE OR ENCLOSED AREA.
WARNING:
WHEN CONNECTING FOR USE:
cKnow the odor of LP-gas. If you hear, see or smell leaking LP-gas,
immediately get everyone away from the cylinder and call the Fire Department.
Do not attempt repairs.
cCaution your LP-gas supplier to: Be certain cylinder is purged of trapped air
prior to first filling. Be certain not to over fill the cylinder.
c Be certain cylinder requalification date is checked. LP-gas is heavier than
air and may settle in low places when dissipating.
cContact with the liquid contents of cylinder will cause freeze burns to the
skin. Do not allow children to tamper or play with cylinder.
ccWhen not connected for use, keep cylinder valve turned off. Self contained
appliances shall be limited
cto a cylinder of 30 lb capacity or less. Do not use, store or transport
cylinder where it would be exposed to high temperatures. Relief valve may
Use only in compliance with appliable codes.
cRead and follow manufacturer’s instructions. ccConsult manufacturer’s
instructions
concerning the cylinder connection provided with your appliance. Be sure
regulator vent is not pointing up.
cTurn off all valves on the appliance. ccDo not check for gas leaks with a
match or
open flame. Apply soapy water at areas marked “X”. Open cylinder valve. If
bubble appears, close valve and have LP-gas service person make needed
repairs. Also, check appliance valves and connections to make sure they do not
leak before lighting appliance.
cLight appliance(s) following manufacturer’s instructions.
cWhen appliance is not is use, keep the cylinder valve closed.
open allowing a large amount of flammable gas to
Cylinder valve hand wheel
escape.
cWhen transporting, keep cylinder secured in an upright position which
cylinder valve turned off.
X
Pressure relief valve
Point of connection
X
X
Cylinder
X
X
Liquid level indicator (optional)
DO NOT REMOVE, DEFACE, OR OBLITERATE THIS LABEL *EXCEPT AS AUTHORIZED BY
ANSI/NFPA 58.
DANGER. Do not store a spare LP cylinder under or near a barbecue grill, or
other heat sources. NEVER fill an LP cylinder beyond 80% full: a fire causing
death or serious injury may occour.
Please keep this instruction manual for future reference
WARNING
READ INSTRUCTION MANUAL BEFORE ATTEMPTING ASSEMBLE OR OPERATE THIS PRODUCT
Keep the screws and parts out of reach of children. (Made in China)
Contact the Customer Service Team at e-mail: customercare@yimohome.com
Safety Information
Read the instruction before use. This appliance must be installed in accordance with such regulations as are enforced.
DANGER: FIRE OR EXPLOSION HAZARD If you smell gas: · Shut off gas to the
appliance. · Extinguish any open flame. · If odor continues, leave the area
immediately · After leaving the area, call your gas supplier
or fire department.
Failure to follow these instructions could result in fire or explosion, which
could cause property damage, personal injury, or death.
DANGER CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent, car or
home.
WARNING: Do not store or use gasoline, or other flammable vapors and liquids,
in the vicinity of this or any other appliance. An LP-cylinder not connected
for use shall not be stored in the vicinity of this or any other appliance.
INSTALLER: leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: For Outdoor Use Only!
Installation and service must be performed by a qualified installer, service
agency, or the gas supplier
WARNING: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, personal injury or loss of life. Read this
installation, operating, and maintenance instructions thoroughly before
installing or servicing this equipment.
WARNING:
FOR YOUR SAFETY:
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life. WHAT TO
DO IF YOU SMELL GAS: Do not try lighting any appliance. Do not touch any
electrical switch; do NOT use any phone in your building. Immediately call
your gas supplier from a neighbor’s phone. Fllow the gas supplier’s
instructions. If you cannot reach your gas supplier. Call the fire department.
Installation and service must be performed by a qualified installer, service
agency or gas supplier. Save these instructions for future reference. If you
are assembling this unit for someone else, give this manual to him or her to
read and save for future reference.
2
Safety Information (continued)
WARNING: You must provide propane gas and propane cylinder. Use a standard 20 lb. propane cylinder only.
Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANS/NFPA 58. Your local library or fire department should have this book.
The pressure regulator and hose assembly supplied with the appliance must be used.
The installation must conform with local codes, or in absence of local codes, with National Fuel Gas Code, ANSI Z223.1.
A dented, rusted, or damaged propane cylinder may be hazardous and should be checked by your cylinder supplier. Never use a propane cylinder with a damaged valve connection.
The LP-gas supply cylinder must be constructed and marked in accordance with the U.S. Department of Transportation (D.O.T) Specifications for LP-Gas Cylinders, or the standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Good and Commission, CAN/CSA-B339, as applicable.
The LP-gas supply cylinder must be provided with a cylinder connection device compatible with the connection for the appliance.
The cylinder used must include a collar to protect the cylinder valve.
The LP-gas supply cylinder must be provided with a listed overfill protection device (OPD).
Do not store a spare LP gas cylinder under or near this appliance.
Never fill the cylinder beyond 80 percent full.
For appliances designed to use a CGA No. 791IQCC connection.
Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use.
Note: Gas supply pressure: 25 PSI to 250 PSI.
Standard 20 lbs. tank
WARNING: FUELS USED IN LIQUIFIED PROPANE GAS APPLIANCES, AND THE PRODUCTS OF
COMBUSTION OF SUCH FUELS, CAN EXPOSE YOU TO CHEMICALS INCLUDING BENZENE, WHICH
IS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND CAUSE BIRTH DEFECTS OR
OTHER REPRODUCTIVE HARM.
WARNING:z Failure to position the parts in accordance with these diagrams or
failure to use only parts specifically approved with this appliance may result
in property damage or personal injury.
3 .
Safety Information (continued)
WARNING: Solid fuels shall not be burned in this appliance. The installation
must conform with local codes or, in the absence of local codes, ANSIZ223.
1/NFPA54, NFPA58 Natural Gas and Propane Installation Code, CSA B149.1, or
Propane Storage and Handling Code, B149.2. Prior to use, check for damaged
parts such as hoses, regulators, pilots, or burners. Inspect the fuel supply
connection for signs of leakage (including the hose for the LP models) before
each use of the appliance. All leak tests should be done with a soapy
solution. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS. Children and adults
should be alerted to the hazards of high surface temperatures and should stay
away from the appliance to avoid burns or clothing ignition. This appliance
comes with a heat shield which is an important safety component preventing
contact with the fire bowl when adjusting the propane valve. Young children
should be carefully supervised when they are in the area of the heater.
Clothing or other flammable materials should be not be hung from the heater,
or placed on or near the heater. Any guard or other protective device removed
for servicing the heater, must be replaced prior to operating the heater.
Installation and repair should be done by a qualified service person. The
heater should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required as necessary. It is
imperative that the control compartment, burners, and circulating air
passageways of the heater be kept clean. Keep the appliance area clear and
free from combustible materials, gasoline, and other flammable vapors and
liquids. DO NOT OBSTRUCT the combustion process or air ventilation flow. Keep
the ventilation opening(s) of the cylinder enclosure free and clear from
debris. The appliance should be used in a well-ventilated space and not in a
building, garage or any other enclosed area. An appliance may be installed
within a shelter if the shelter meets one of the following conditions: The
shelter has walls on all sides, but with no overhead cover. The shelter is
within a partial enclosure which includes side walls. These side walls may be
parallel, as in a breezeway, or at right angles to each other.
4
Warranty
1 YEAR LIMITED WARRANTY
· We warrant the metal frame and burner to be free of manufacturing defects to
the original purchaser for one years. · Proof of purchase (dated register
receipt) is required for warranty claims.
WHAT IS NOT COVER
It remains the customer’s responsibility for freight and packaging charges to
and from our service center. This warranty does not cover commercial use, acts
of nature, fire, freezing and abusive use. In addition, purchased parts are
not covered under this warranty. We reserve the right to make substitutions
with similar merchandise, if the model in question is no longer in production.
Pre-Assembly
PLANNING ASSEMBLY
Carefully remove all pieces from the carton and make sure that you have all
parts (refer to the hardware and package contents list). If you are missing
parts, please contact after-services for further assistance.
YOUR OWNER’S MANUAL
Keep and store this Owner’s Manual for future reference. It contains important
instructions and procedures for safety and maintenance.
NOTE: Please read and understand the entire manual before you assemble,
operate, or install the fire pit.
TOOLS REQUIRED (NOT INCLUDED)
Phillips screwdriver
M6 Wrench
HARDWARE INCLUDED
Part Description
AA
M6 x mm Bolt
BB
M6 x 16 mm Bolt
CC
M x 2 mm Bolt
DD
Quantity 16
4
AA
BB
CC DD
5
Package Contents E F G B
C
Part A B C D E F G H
Description Side Panel with Window Side Panel Door Back Panel
Fire Glass Table Top with Burner Gas tank support
Quantity 1 1 1 1 1 1 1 1
6
D A
H
Assembly
1 Assembling the side panels BB Connect the side panel (B) to the door(C) by
using one M6x16 bolt(BB). B
C
Don’t tighten the hardware.
2 Assembling the side panel with window
Connect the side panel with window(A
to the table top(G) by using four M6x10 mm bolts(AA). Do not tighten the bolts
at this step.
Attach the control panel to the side panel with window (A) by using four M5x12
mm bolts(CC) and tighten them.
A
AA
CC
7
HOSE
Assembly (continued)
3 Assembling the side panel
Connect the side panel (Band door(C) to the table top (G) by using four M6x10 mm bolts(AA) B
Do not tighten the bolts at this step.
A
AA
4 Assembling the back panel
Connect the back panel(D) to the side panel with window (A) and side panel (B)
by using four M6x10 mm bolts(AA)
Tighten all bolts (AA) with a Phillips screwdriver (not included). AA
D
Do not tighten the bolts at this step.
B A
8
Assembly (continued)
5 Assembling the Door
AA
Connect gas tank support (H) to the semi-assembled body
by using four M6x10 mm bolts(AA)
D
B A
Tighten all bolts (AA) with a Phillips screwdriver (not included).
C
6 1MBDFUIFGJSFHMBTT
Place the fire glass (F) into the fire bowl.
fire glass is
E F
Ignition
9
Assembly (continued)
Assembling the cylinder
H ,
secure the cylinder by tightening the screw in the gas
tank support. Connect the hose and regulator to cylinder.
NOTE: The propane cylinder is sold separately. Use a standard 20 lb. propane
cylinder only. Put the hose away from the bowl base during connect the propane
cylinder.
Connect: Hand-tighten the coupling nut clockwise until it comes to a full
stop. Firmly tighten by hand only.
To Disconnect: Fully close the tank valve by turning clockwise. Turn the
coupling nut counterclockwise until the regulator assembly detaches.
Installing the AAA battery
Open the igniter and place the AAA battery (DD) into the igniter. Then tighten
clockwise.
AAA Battery
10
Operating
WARNING: Never use this appliance for other than the intended use. DO NOT use
this appliance to prepare food.
Initial Lighting: When lit for the first time, the appliance emits a slight
odor. This is a normal temporary condition caused by the “burn-in ” of
internal paints and lubricants used in the manufacturing process and does not
occur again. Simply run the main burner on high for approximately one-half
hour.
WARNING: Children and adults should be alerted to the hazards of high surface
temperatures and should stay away from the appliance to avoid burns or
clothing ignition. The appliance comes with a heat shield which is an
important safety component preventing contact with the fire bowl when
adjusting the propane valve. Children should be carefully supervised when they
are in the area of the appliance. Clothing or other flammable materials should
not be hung from the appliance, or placed on or near the appliance. The area
above the fire pit may be extremely hot. Direct contact with these surfaces
should be avoided in order to prevent burns or clothing ignition. Any guard or
protective device removed for servicing the appliance must be replaced prior
to operating the appliance. Installation and repair should be done by a
qualified service person. The appliance should be inspected before each use
and at least annually by a qualified service person. More frequent cleaning
may be required necessary. It is imperative that the control compartment,
burners and circulating air passageways of the appliance be kept clean.
WARNING: Never use the appliance while it is raining. Always turn the
appliance off when raining. Never use the appliance if the burner is damaged.
Inspect the burner before each use. Ensure that no debris such as leaves;
grass or other objects have entered or are on the appliance. If the burner is
damaged it must be replaced prior to using this appliance with a replacement
burner specified by your dealer. Inspect the hose assembly before each use. If
there is evidence of excessive abrasion or wear, or if the hose is damaged it
must be replaced prior to using the appliance with a replacement hose assembly
specified by your dealer.
WARNING: Any modification to the appliance may compromise the safety of this
appliance. Special concern is as follows: Do not bypass the thermocouple
safety. Do not operate the appliance if any parts have been under water.
Immediately call a qualified service technician to inspect the appliance and
replace any part of the control system, and any gas control, which has been
under water.
11
Operating (continued)
LEAK TESTING OPERATION
WARNING: A leak test must be performed annually or if a part of the gas system
is replaced.
WARNING: Never use an open flame to check for gas leaks. Be certain no sparks
or open flames are in the area while you check for leaks. Sparks or open
flames will result in a fire or explosion, damage to property, serious bodily
injury, or death.
LEAK TESTING: 1, Make 2-3 oz. of leak detection solution by mixing one part
liquid dishwashing soap with three parts water. 2, Make sure all fire pit and
light valves are OFF 3, Apply several drops of solution where hose attaches to
regulator. 4, Apply several drops of solution where regulator connects to
cylinder. 5, Turn cylinder valve ON. If bubbles appear at any connection,
there is a leak. 1, Turn cylinder valve OFF. 2, If leak is at hose/regulator
connection: tighten connection and perform another leak test. If bubbles
continue appearing,
pls contact after-services for assistance. 3, If leak is at regulator/cylinder
valve connection: disconnect, reconnect, and perform another leak test. If you
continue
to see bubbles after several attempts, cylinder valve is defective, and
contact after services for assistance.
If NO bubbles appear at any connection, the connections are secure. NOTE:
Whenever gas connections are loosened or removed, you must perform a complete
leak test .
Hose/Regulator Connection
Regulator/Cylinder Connection
12
Operating (continued)
LIGHTING
CAUTION: Keep the outdoor gas appliance area clear and free from combustible
materials, gasoline and other flammable vapors and liquids. CAUTION: Do NOT
obstruct the flow of combustion and ventilation air. CAUTION: Check and clean
burner/venturi tubes for insects and insect nests. A clogged tube can lead to
a fire. 1. Make sure all labels, packaging and protective films have been
removed from the outdoor fire pit. 2. Control knob must be in the “OFF”
position (Figure 1). 3. Full open LP cylinder valve. 4. Press and hold
electronic igniter button. 5. Press the control knob, turn counterclockwise to
“Low” position, press and hold. When the burner lights, release the electronic
igniter button (Figure 2). 6. Continue to depress the gas control knob for 30
seconds and then release. If the flame goes out, repeat the procedure. 7.
Adjust the flame to the desired height with the gas control knob. Visually
check the burner flames as picture below (Figure 3). 8. If the burner will not
light with the electronic igniter, hold a lit long match or lit long butane
lighter to the ignition area of the burner and continue with step 5.
WARNING: If the burner does not light within 10 seconds, turn the valve off
and wait 5 minutes for gas to dissipate before repeating the procedure
WARNING: Surface of the fire pit can remain extremely hot for a period after
use. Allow 45 minutes to cool to dissipate before repeating the procedure.
Improper operation, can cause injury or property damage.
Figure 1
Figure 2
Figure 3
Shut Down 1. To extinguish burner depress control knob and continue to turn it clockwise to “OFF” 2. Turn cylinder valve clockwise to “OFF” and disconnect regulator when fire pit is not in use.
Maintenance
Storage between uses:
Turn the control knob to “OFF” position. Disconnect LP source. Store heater
upright in an area sheltered from direct contact with inclement weather (such
as rain, sleet, hail, snow, dust
and debris). If desired, cover heater to protect exterior surfaces and to help
prevent build up in air passages.
NOTE: Wait until heater is cool before covering.
Storage during periods of extended inactivity or when transporting:
Turn the control knob to “OFF” position. Disconnect LP source and move to a
secure, well ventilated location outdoors. DO NOT store in a location that
will
exceed 125. Store heater upright in an area sheltered from direct contact with
inclement weather (such as rain, sleet, hail, snow, dust
and debris). If desired, cover heater to protect exterior surfaces and to help
prevent build up in air passages.
NOTE: Wait until heater is cool before covering.
Care and Cleaning
To enjoy years of outstanding performance from your heater, make sure you
perform the following maintenance activities on a regular basis:
Whenever conduct hose/regulator inspection, pull out the door using handle on
the door panel to gain access. Keep exterior surface clean. Use warm soapy
water for cleaning. Never use flammable or corrosive cleaning agents. While
washing your unit, be sure to keep the area around the burner dry at all
times. If the gas control is exposed to
water, do NOT try to use it. It must be replaced. Keep the appliance area free
and clean from combustible materials, gasoline or other flammable vapors and
liquids. At least once a year, the unit should be inspected for the presence
of spiders, spider webs or other insects. Air flow must be unobstructed. Keep
controls, burner, and circulating air passageways clean. Signs of possible
blockage include: Gas odor with extreme yellow tipping of flame. Heater does
NOT reach the desired temperature. Heat glow is excessively uneven. Heat makes
popping noises. Spider and insects can nest in burner or orifices. This
dangerous condition can damage heater and render it unsafe for use. Clean
burner holes by using a heavy-duty pipe cleaner. Compressed air may help clear
away smaller particles. Carbon deposits may create a fire hazard. Clean
reflector, thermocouple, and emitter screen with a dry cloth if any carbon
deposits develop. The burner is made from stainless steel, but extreme heat
and a corrosive environment can cause surface corrosion to occur. This can be
removed with a brass wire brush. Inspect the burner at least annually for
cracks, insect nests, excessive corrosion or any other damage. If the burner
is damaged, it must be replaced with a burner specified by the manufacturer
before the appliance is put into operation.
14
Troubleshooting
PROBLEM
PROBLEM CAUSE
SOLUTION
The flame and heat are low when the valve is turned to high.
Burners burn with yellow flame, accompanied by the smell of gas. The burner
will not light with the igniter, but will light with a match.
The burner will not stay lit when control knob is released.
The propane lighting procedure was not followed correctly.
Ensure lighting procedure is followed carefully. The valve must be in the off position when the tank valve is turned on. Turn the tank on slowly to allow pressure to equalize. See Lighting Instructions in the Operating section.
There is possibly a spider web Thoroughly clean the burner venturi. See the Maintenance
or other debris.
section.
The battery is either dead or Check the installation or replace with a new battery. installed incorrectly.
There is a loose electrode wire Check that the electrode wire is firmly pushed onto the
or switch terminal wires.
terminal on the back of the igniter. Check that the lead wires
from the module to the ignition switch (if equipped) are firmly
pushed onto their respective terminals.
The knob is not being held in The thermocouple must have time to heat up. Hold the knob
long enough.
in for 30 seconds after the burner lights, then release.
It is too windy outside.
The unit will shut down if winds are greater than 10 mph (16 km/h). Either locate the fire pit to a different area or use when it is less windy.
Lava rock or debris are in the ignition area of the burner preventing the thermocouple from being fully engulfed in flame.
Ensure there is no lava rock or other debris in the ignition area, and that the small hole below the thermocouple is unobstructed.
Either the thermocouple or thermocouple connection is dirty.
Clean the thermocouple and clean the connection between the valve and thermocouple. Ensure the connection is properly tightened.
Either the thermocouple or valve is faulty.
Replace thermocouple and/or valve.
The regulator is humming. This is a normal occurrence on hot days.
This is not a defect. It is caused by internal vibrations in the regulator and does not affect the performance or safety of the gas heater. Humming regulator will not be replaced.
The valve is set to high but there is low heat output. There is also a rumbling noise and a fluttering blue flame at the burner surface.
There is not enough gas. The supply hose is pinched.
Check the gas level in the propane cylinder. Reposition the supply hose as necessary.
The burner orifice is either dirty or clogged.
Clean the burner orifice.
There are spider webs or other Clean out the venturi tube. matter in venturi tube.
The propane regulator is in a “low flow” state.
Ensure the lighting procedure is followed carefully. All valves must be in the off position when the tank valve is turned on. Turn tank on slowly to allow pressure to equalize. See the Lighting Instructions in the Operating section.