CyberPower LX1100G Systems Battery Back-up UPS User Manual

June 12, 2024
CyberPower

CyberPower LX1100G Systems Battery Back-up UPS

Cyberpower Lx1100g Systems Battery Back-up Ups

FEATURES

Features

  1. Power Switch
  2. Power On Indicator 3
  3. LCD Module Display
  4. LCD Display Toggle/Selected Switch
  5. USB Port (except for LX1000G)
  6. Battery and Surge Protection Outlets 13 13
  7. Full Time Surge Protection Outlets
  8. Circuit Breaker
  9. USB Ports to PC
  10. Communication Protection Ports
  11. Wiring Fault Indicator (red)
  12. Coax/Cable. DSS Surge Protection
  13. Power Switch
  14. Widely-Spaced Outlets Designed for AC Adapters

PRODUCT REGISTRATION

Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at: www.cyberpower.com/registration.
Registration certifies your product’s warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership.

IMPORTANT SAFETY WARNINGS

(SAVE THESE INSTRUCTIONS)

This Manual Contains Important Instructions that should be followed during Installation and Maintenance of the UPS and batteries.

CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range).

CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn of and unplug the unit before servicing the batteries. There are no user serviceable parts inside except for the battery.

CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.

CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75.

CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn of and unplug the unit.

CAUTION! To avoid electric shock, turn of the unit and unplug it from the AC power source before servicing the battery.

CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code, ANSI/NFPA 70.

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical applications. DO NOT use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or patient care.

DO   NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.

DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.

INSTALLING YOUR UPS SYSTEM

INTRODUCTION

Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and performance during the lifetime of the product.

UNPACKING

Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS
(b) User’s manual
(c) USB A+B device cable
(d) Function Setup Guide
*Power Panel® Personal software is available on our website. Please visit www.cyberpower.com and go to the Software Section for free download.

OVERVIEW

The LX1100G/LX1325GU/LX1500GU provides complete power protection from utility power that is not always consistent. The LX1100G/LX1325GU/ LX1500GU features 890 Joules of surge protection. The unit provides long lasting battery backup during power outages with maintenance free batteries. The LX1100G/LX1325GU/LX1500GU ensures consistent power to your computer system and includes software that will automatically save your open files and shutdown your computer system during a utility power loss.

AUTOMATIC VOLTAGE REGULATOR

The LX1100G/LX1325GU/LX1500GU stabilizes inconsistent utility power voltage to nominal levels that are safe for equipment. Inconsistent incoming utility power may be damaging to important data files and hardware, but with Automatic Voltage Regulation (AVR), damaging voltage levels are corrected to safe levels. AVR automatically increases low utility power or decreases high utility power to a consistent and safe 110/120 volts.

DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
  1. Ensure that the equipment plugged into the outlet does not exceed the UPS’s rated capacity. If the rated capacity of the unit is exceeded, an overload condition may occur and cause the UPS to shut down or the circuit breaker to trip.
  2. There are many factors that can affect the amount of power that your computer system will require. It is suggested that the load placed on the battery outlets not exceed 80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
  1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the battery’s maximum charge capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or of.

  2. Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment. The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up.

  3. With the UPS unit turned of and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup into the battery power supplied outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical devices into the “Battery and Surge Protected Outlets”. The power demands of these devices may overload and damage the UPS.

  4. Plug the UPS into a 2-pole, 3-wire  grounded receptacle (wall outlet).Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, copier, etc…).
    The warranty prohibits the use of extension cords, outlet strips, and surge strips.

  5. Press the power switch to turn the unit on. The Power On indicator light will illuminate and the unit will “beep”. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS of and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.

  6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.

  7. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three months to ensure battery life.

  8. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.

BASIC OPERATION

  1. Power Switch Used as the master on/ 7. Full Time Surge Protection Outlets of switch for equipment connected The UPS has five surge suppression to the battery power supplied outlets. outlets.
    (Please refer to the Function Setup 8. Circuit Breaker Located on the Guide for more information.)

  2. Power On Indicator This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.

  3. LCD module display The LCD display shows all the UPS information  using icons and messages. For more information please review the “Definitions for Illuminated LCD Indicators” section below.

  4. LCD Display Toggle/Selected Switch The switch can be used to select the LCD display contents including Input Voltage, Output Voltage, and Estimated Run Time. Click the button to scroll down the function menu. Pressing the button for 3 seconds will keep the LCD display always on or turn the LCD display of while in AC/Utility power mode. For more Information, please refer the Function Setup Guide.

  5. USB Charging Ports (except for LX1100G) The USB Charging ports provide 5V 2.1A power output.

  6. Battery and Surge Protected Outlets The UPS has five battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical devices into the “Battery and Surge Protected Outlets”. The power demands of these devices may overload and damage the unit.)

  7. Full Time Surge Protection Outlets The UPS has five surge suppression outlets.

  8. Circuit Breaker Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.

  9. USB Ports to PC The USB port allows connection and communication between the USB port on the computer and the UPS unit.

  10. Communication Protection Ports Communication protection ports, bi- directional, will protect a 10/100/1000 Ethernet connection (RJ45).

  11. Wiring Fault Indicator (red) This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired.  The UPS will not provide surge  protection without being plugged into a grounded and properly wired wall outlet.

  12. Coax/Cable/DSS Surge Protection The Coax/Cable/DSS protection ports will protect any cable modem, CATV  converter, or DSS receiver.

  13. Outlets Designed for AC Adapters The unit has two outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets.

REPLACING THE BATTERY

Replacement of batteries located in an OPERATOR ACCESS AREA

  1. When replacing batteries, replace with the same number of the following battery:
    CyberPower / RB1270X2C for the LX1100G / LX1325GU, and CyberPower / RB1290X2 for the LX1500GU.

  2. CAUTION! Risk of Energy Hazard, 12V, maximum 9 Ampere-hour battery. Before replacing batteries, remove conductive jewelry such as chains, wrist watches, and rings. High energy through conductive materials could cause severe burns.

  3. CAUTION! Do not dispose of batteries in a fire. The batteries may explode

  4. CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic.

  5. CAUTION! A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:

  6. Remove watches rings, or other metal objects.

  7. Use tools with insulated handles.

CAUTION – RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS.

REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead acid batteries collect used batteries for recycling, as required by local regulations.

BATTERY REPLACEMENT PROCEDURE

  1. Turn of and unplug all connected equipment.

  2. Turn the UPS of and unplug it from the AC power source.

  3. Turn the UPS on its side.

  4. Remove two retaining screws located on the bottom of the UPS.

  5. Slide the battery compartment cover completely of of the unit.

  6.  Remove the battery which is located on the right side from the compartment.
    Battery Replacement Procedure

  7. Disconnect the battery wires from the right side of the battery.
    Battery Replacement Procedure

  8. Slide the remaining battery from left to right and remove it from the compartment.

  9. Disconnect the battery wires from the remaining battery.

  10. Install the “left side” replacement battery by connecting the yellow wire (+) to the red connector from the battery and the black wire (-) to the black connector from the battery. Place the battery into the left side of the compartment.

  11.  Install the “right side” replacement battery by connecting the red wire (+) to the red connector from the battery and yellow wire (-) to the black connector from the battery. Place the battery into the right side of the compartment. Note: Only new batteries should be used for replacement and both batteries should be replaced at the same time to insure maximum life span.

  12. Slide back the battery compartment cover and tighten the retaining screws.

  13. Recharge the UPS for 8-16 hours to fully charge the battery.

DEFINITIONS FOR ILLUMINATED LED INDICATORS

The LCD display indicates a variety of UPS operational conditions. All descriptions apply when the UPS is plugged into an AC outlet and turned on or when the UPS is on battery.

INPUT voltage meter:
This meter measures the AC voltage that the UPS system is receiving from the utility wall outlet. The UPS is designed to continuously supply connected equipment with stable output voltage. In the event of a complete power loss, severe brownout, or over-voltage, the UPS relies on its internal battery to supply consistent 110/120 output voltage. The INPUT voltage meter can be used as a diagnostic tool to identify poor quality input power.
OUTPUT voltage meter:
This meter measures, in real time, the AC voltage that the UPS system is providing to the computer during normal AC/Utility Power mode, and battery backup mode.
ESTIMATED RUNTIME:
This displays the run time estimate of the UPS with the current battery capacity and load.
NORMAL icon:
This icon appears when the UPS is working under normal conditions.
BATTERY icon:
During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate the UPS is operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously to indicate the UPS’s batteries are nearly out of power. You should save files and turn of your equipment immediately or allow the software to shut the system down.
OVER LOAD icon:
This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, unplug some of your equipment from the battery supplied outlets until the icon turns of and the alarm stops.
BATTERY icon:
During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate the UPS is operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously to indicate the UPS’s batteries are nearly out of power. You should save files and turn of your equipment immediately or allow the software to shut the system down.
AVR (Automatic Voltage Regulation) icon:
This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power. This is a normal, automatic operation of your UPS, and no action is required on your part.
SILENT MODE icon:
This icon appears whenever the UPS is in silent mode. The buzzer does not beep during silent mode until the battery reaches low capacity.
OVER LOAD icon::
This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, unplug some of your equipment from the battery supplied outlets until the icon turns of and the alarm stops.
FAULT:
This icon appears if there is a problem with the UPS. Press the POWER button to turn the UPS of.
F01: Battery Mode or AC/Utility Power Mode Overload fault (Unplug at least one piece of equipment from battery outlets and turn the UPS on again.)
F02: Battery Output Short fault (Unplug at least one piece of equipment from battery outlets and turn the UPS on again.)
F03: Charger Fault (Contact CyberPower Systems for support.)
F04: Internal Fault (Contact CyberPower Systems for support.)
BATT. CAPACITY meter:
This meter displays the approximate charge level (in 20% increments) of the UPS’s internal battery. During a blackout or severe brownout, the UPS switches to battery power, the BATTERY icon appears, and the charge level decreases.
LOAD CAPACITY meter:
This meter displays the approximate output load level (in 20% increments) of the UPS battery outlets.

For more information about functions setup, please refer to the Function Setup Guide.

TECHNICAL SPECIFICATIONS

Model

| LX1100G| LX1325GU|

LX1500GU

---|---|---|---

Capacity

| 1100 VA / 660W| 1325VA / 810W| 1500VA / 900W
Nominal Input Voltage|

120Vac

Input Frequency

| 60 Hz +/- 3 Hz
On-Battery Output Voltage|

120Vac +/- 5%

Max. Load for UPS Outlets (5 outlets)

| 1100 VA / 660W| 1325VA / 810W| 1500VA / 900W
Max. Load for Full-Time Surge Protection Outlets (10 outlets)|

12 A

On-Battery Output Frequency

| 60 Hz +/- 1%
On-Battery Output Wave Form|

Simulated Sine Wave

Operating Temperature

| + 32°F to 104° F / 0° C to 40° C
Operating Relative Humidity|

0 to 90% non-condensing

Size (width / height / depth)

| 3.9 x 9.8 x 13.7 in. (99 x 249 x 348 mm)
Net Weight| 21.8 lbs. / 9.9 kg|

22.2 lbs. / 10.1 kg

| 25 lbs. / 11.3 kg

Battery Type

| CyberPower / RB1270X2C| CyberPower / RB1270X2C| CyberPower / RB1290X2
Typical Battery Recharge Time|

8 hours to 90% capacity from total discharge

Typical Battery Life

| 3 to 6 years, depending on number of discharge/recharge cycles
Recommended Battery|

Sealed Maintenance Free Lead Acid Battery

Safety Approvals

|

UL1778(UPS), cUL107., FCC/DoC Class B

SYSTEM FUNCTION BLOCK DIAGRAM

System Function Block Diagram

TROUBLESHOOTING

Problem Possible Cause Solution
Circuit breaker button is projecting from the back of the unit. Circuit
breaker has been tripped due to an overload. Turn the UPS off and unplug at

least one piece of equipment. Wait 10 seconds, reset the circuit breaker by pressing the button, and then turn the UPS on.
The UPS does not perform| Battery not fully charged.| Recharge the battery by leaving the UPS plugged in.
expected runtime.| Battery is worn out.| Contact CyberPower Systems about replacement batteries at: c yberpowersystems.com/support.
The UPS will not turn on.| The on/off switch is designed to prevent damage from rapidly turning it off and on.| Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The unit is not connected to an AC outlet.| The unit must be connected to a 120V 60Hz outlet.
The battery is worn out.| Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support.
Mechanical problem.| Contact CyberPower Systems at: cyberpowersystems.com/support.
The frequency is outside of the operating range of 57 to 63Hz.| Turn the UPS off. Make sure the frequency range is within 57 to 63Hz. Or you can turn the UPS on in battery mode.
Power Panel® Personal is inactive (all icons are gray).| The USB / serial cable is not connected.| Connect the USB / serial cable to the UPS unit and an open USB / serial port on the back of the computer. You must use the cable that came with the unit.
The USB / serial cable is connected to the wrong port.| Check the back of the computer for an additional USB / serial port. Move the cable to this port.
The unit is not providing battery power.| Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit.
The USB power ports are not providing power to the connected devices.| The USB power port has Over Current Protection design. When the total current of connected devices is over 2.1A, the USB power ports will stop providing power to the connected devices.| Turn the UPS off and unplug at least one piece of device connected to the USB power port and then turn the UPS on.

Additional troubleshooting information can be found at “Support” at www.CyberPowerSystems.com

CYBERPOWER GREENPOWER UPS™ TECHNOLOGY

Advanced Energy-Saving Design

The Green Power UPS™ has a high efficiency charger, which makes it the most energy efficient UPS in its class. The advanced high frequency charging system significantly improves charging efficiency and conserves energy. As a result of this advanced design, the Green Power UPS™ uses less energy compared to competitive models. The Green Power UPS™ is manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the most environmentally friendly UPS systems on the market today.

GREENPOWER UPS™
Energy-Saving Technology

FCC COMPLIANCE STATEMENT

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment of and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
    Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Canadian Compliance Statement
CAN ICES-3 (B)/NMB-3(B)

LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE

Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee.

Customer Support

Where Can I Get More Information?

The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty. For further information please feel free to contact CyberPower at:

Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal and recycling of its UPS products. Please dispose and/or recycle your UPS and batteries in accordance to the local regulations of your state.

WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.

Customer Service

© 2023 CyberPower Systems (USA), Inc. Power Panel® Personal is a trademark of Cyber Power Systems(USA) Inc.
All rights reserved. All other trademarks are the property of their respective owners.

Cyber Power Systems (USA), Inc.