MEAN WELL EPP-200 200W Single Output with PFC Function Instruction Manual

June 4, 2024
MEAN WELL

MEAN WELL EPP-200 200W Single Output with PFC Function

MEAN-WELL-EPP-200-200W-Single-Output-with-PFC-Function-PRODUCT-
IMAGE. Features

  • 4″×2″ miniature size
  • Universal AC input / Full range
  • Built-in active PFC function
  • EMI Conduction for Class B Radiation for Class B with FG(Class Ⅰ) and Class A without FG(Class Ⅱ)
  • No load power consumption<0.5W
  • High efficiency up to 94%
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection for 140W and 200W with 10CFM forced air
  • Built-in 12V/0.5A FAN supply
  • LED indicator for power on
  • Operating altitude up to 5000 meters
  • 3 years warranty
Applications
  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipment’s or apparatus
Description

EPP-200 is a 200W highly reliable green PCB type power supply with a high power density (21.9W/in3) on the 4″ by 2″ footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 48V. The working efficiency is up to 94% and the extremely low no load power consumption is down below 0.5W. EPP-200 is able to be used for both ClassⅠ(with FG) and Class Ⅱ(no FG) system design. EPP-200 is equipped with complete protection functions; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, UL62368-1 and IEC62368-1. EPP-200 series serves as a high price-to-performance power supply solution for various industrial applications.

Model Encoding

Specifications

MODEL| EPP-200-12| EPP-200-15| EPP-200-24| EPP-200-27| EPP-200-48
---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 24V| 27V| 48V


CURRENT

| 10CFM| 16.7A| 13.4A| 8.4A| 7.5A| 4.2A
Convection| 11.7A| 9.4A| 5.9A| 5.3A| 3A
RATED POWER| 10CFM| 200.4W| 201W| 201.6W| 202.5W| 201.6W
Convection| 140.4W| 141W| 141.6W| 143.1W| 144W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 11.4~12.6V| 14.3~15.8V| 22.8~25.2V| 25.6 ~ 28.4V| 45.6 ~50.4V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.5%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 500ms, 30ms/230VAC         500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 12ms/230VAC         12ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.4| 80 ~ 264VAC         113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.94/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 93%| 93%| 94%| 94%| 94%
AC CURRENT (Typ.)| 1.8A/115VAC         1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 30A/115VAC         60A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC




PROTECTION

| OVERLOAD| 110 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 26.4 ~ 31.2V| 29.7 ~ 35V| 52.8 ~ 62.4V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION| FAN SUPPLY| [email protected] for driving a fan ; tolerance +15% ~ -15%
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
OPERATING ALTITUDE Note.6| 5000 meters
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes



SAFETY & EMC

(Note 5)

| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, IEC62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Conduction for Class B Radiation for Class B with FG(ClassⅠ) and Class A without FG(ClassⅡ), BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61000-6-2, heavy industry level,

criteria A, EAC TP TC 020

OTHERS| MTBF| 500.2Khrs min.      MIL-HDBK-217F (25℃)
DIMENSION| 101.650.829mm  (LWH)
PACKING| 0.19Kg; 72pcs/14.7Kg/0.82CUFT
NOTE|

  1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Derating Curve
Output Derating VS Input Voltage

Mechanical Specification

MEAN-WELL-EPP-200-200W-Single-Output-with-PFC-
Function-05 MEAN-WELL-EPP-200-200W-Single-
Output-with-PFC-Function-06

AC Input Connector (CN1) : JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2 No Pin
3 AC/N

Grounding required

DC Output Connector (CN2) : JST B6P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2,3 +V JST VHRor equivalent JST SVH-21T-P1.1 or equivalent

FAN Connector(CN101) : JST B2B-PH-K-S or equivalent

Pin No. Assignment Mating Housing Terminal
1 DC COM JST PHR-2 or equivalent JST SPH-002T-P0.5S or equivalent
2 +12V

Note :

  1. The FAN supply is designed to serve as the source of the additive external fan for the cooling of the power supply, enabling the full load delivery and assuring the best life span of the product. Please do not use this FAN supply to drive other devices.
  2. EMI Conduction for Class B Radiation for Class B with FG(ClassⅠ) and Class A without FG(ClassⅡ).

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals