MEAN WELL EPP-100 100W Single Output with PFC Function Instruction Manual

June 4, 2024
MEAN WELL

100W Single Output with PFC Function
EPP-100 series

MEAN WELL Single Output with PFC Function 01

Features:

  • 4″x2″ Compact size
  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 92.5%
  • Protections: Short circuit / Overload / Over voltage/Over temperature
  • 75W free air convection, 100W with 20CFM forced air
  • LED indicator for power on
  • No load power consumption<0.5W
  • Built-in 12V/0.3A auxiliary output
  • 3 years warranty

MEAN WELL Single Output with PFC Function Certi

SPECIFICATION

MODEL| EPP-100-12| EPP-100-15| EPP-100-24| EPP-100-27| EPP-100-48
---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 24V| 27V| 48V
RATED CURRENT (convection)| 6.3A| 5A| 3.2A| 2.8A| 1.6A
RATED CURRENT (20CFM FAN)| 8.5A| 6.67A| 4.2A| 3.71A| 2.1A
CURRENT RANGE (convection)| 0 ~ 6.3A| 0 ~ 5A| 0 ~ 3.2A| 0 ~ 2.8A| 0 ~ 1.6A
CURRENT RANGE (20CFM FAN)| 0 ~ 8.5A| 0 ~ 6.67A| 0 ~ 4.2A| 0 ~ 3.71A| 0 ~ 2.1A
RATED POWER (convection)| 75.6W| 75W| 76.8W| 75.6W| 76.8W
RATED POWER (20CFM FAN)| 102W| 100.05W| 100.8W| 100.17W| 100.8W
RIPPLE & NOISE (max.) Note.2| 120mVp-p| 150mVp-p| 240mVp-p| 240mVp-p| 300mVp-p
VOLTAGE ADJ. RANGE| 11.76 ~ 12.6V| 14.7 ~ 15.75V| 23.52 ~ 25.2V| 26.46 ~ 28.35V| 47.04 ~ 50.4V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC 16ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.5| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 91%| 91%| 92%| 92.5%| 92.5%
AC CURRENT (Typ.)| 1.4A/115VAC 0.7A/230VAC
INRUSH CURRENT (Typ.)| COLD START 70A/230VAC
LEAKAGE CURRENT| <2mA/240VAC
PROTECTION| OVER LOAD| 105 ~ 145% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 13.2 ~ 15.6V| 16.83 ~ 19.5V| 27.7 ~ 31.5V| 30.2 ~ 34.05V| 51.3 ~ 62.7V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| 110℃±10℃ (RTH2),110℃±5℃ (TSW2)
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION| AUXILIARY POWER(AUX)| 12V@0.3A for driving a fan, tolerance ± 10% at main output 100% load
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 45℃)
OPERATING ALTITUDE Note.6| 2000 meters
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A, EAC TP TC 020
OTHERS| MTBF| 249.6Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 101.650.829mm (LWH)
PACKING| 0.2Kg; 72pcs/15.4Kg/0.82CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
  5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. The ambient temperature derating of 3.5’C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

■ Mechanical Specification

Unit:mm

MEAN WELL Single Output with PFC Function 02

AC Input Connector (CN1) : JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2 No Pin
3 AC/N

: Grounding required

DC Output Connector (CN2) : JST B4P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2 DC COM JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
3,4 +V

FAN Connector(CN105) : JST B2B-PH-K-S or equivalent

Pin No. Assignment Mating Housing Terminal
1 +12V JST PHR-2 or equivalent JST SPH-002T-P0.5S or equivalent
2 DC COM
■ Block Diagram

PFC fosc : 47KHz
PWM fosc : 65KHz

MEAN WELL Single Output with PFC Function 03

■ Output Derating

MEAN WELL Single Output with PFC Function 04

■ Output Derating VS Input Voltage

MEAN WELL Single Output with PFC Function 05

File Name:EPP-100-SPEC 2021-09-15

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals