SJE RHOMBUS Installer Friendly Series Three Phase Control Panel Instruction Manual

June 12, 2024
SJE RHOMBUS

SJE RHOMBUS Installer Friendly Series Three Phase Control Panel

Instruction Manual

INSTALLER FRIENDLY SERIES® (IFS) IN-SITE®
SINGLE PHASE DUPLEX

Demand Dose or Timed Dose, Float or C-Level™ Sensor Controlled System for Pump Control, System Monitoring, Event Logging and Reporting

Parts

The IFS In-Site® duplex control panel utilizes an innovative circuit board design to control two alternating 120/208/240V single phase pumps in water and sewage applications. IFS panels feature an easy-to-use touch pad on inner door for programming and system monitoring. The alternating action equalizes pump wear. In addition, this system provides override control should either pump fail. Quick retrieval of all system events can be done by downloading panel information onto a USB flash drive. The panel configuration can be easily converted in the field to either a timed dose or demand dose. Available with the EZconnex® float system.

Monitor system events including pump run times, pump cycles, alarm conditions, power outages, service calls and more! Quick, convenient reports make diagnosing system conditions easy! Plug the flash drive into the USB port located on the inner door of the IFS In-Site® panel to download system events which occurred. No computer is needed at the site! Use the flash drive (included with panel) with any computer to download system information and reports. The pre-loaded software on the flash drive formulates system data for you, creating reports quickly in an easy-to-read format so system conditions can be easily identified and corrected. In addition to monitoring system events, the IFS In-Site® panel logs any service calls and changes made to system settings, which helps protect service providers.

The panel can utilize the C-Level™ sensor for continuous level monitoring. It senses the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the panel touch pad. C-Level™ CL40 sensor operating range is 3-39.9 inches (7.6-101.3 cm). C-Level™ CL100 operating range is 3-99.5 inches (7.6-252.7 cm).

TOUCH PAD FEATURES

A. Level Status indicators illuminate when floats or set points are activated; alarm will activate if a float operates out of sequence
B. HOA (Hand-Off-Automatic) buttons with indication control pump mode; Hand mode defaults to Automatic when stop level or redundant off level is reached
C. Pump Run indicators will illuminate when pumps are called to run
D. LED display for system information including: level in inches or centimeters (C-Level™ only), mode, pumps elapsed time (hh:mm), events (cycles), alarm counter, float error count, timed dose override counter (timed dose only), pump ON/OFF times (timed dose only), and sequence ON/OFF times (timed dose only)
E. NEXT push button toggles display
F. UP and SET Push Buttons used to set pump ON/OFF times (timed dose only), pump operation (alternate 1-2 and 2-1), date and hour, activation levels (C-Level™ only)

COMPONENTS

  1. Enclosure base measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm); NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use)
  2. Red LED beacon provides 360° visual check of alarm condition
  3. Exterior Alarm Test/Normal/Silence switch allows horn and light to be tested and horn to be silenced in an alarm condition; alarm automatically resets once alarm condition is cleared
  4. Alarm horn provides audio warning of alarm condition (83 to 85 decibel rating)
  5. Circuit breakers (optional) provide pump disconnect and branch circuit protection
  6. Power relays control pump by switching electrical lines; definite purpose contactors used when pump full load amps are above 15
  7. Float connection terminal block
  8. Incoming Control/Alarm Terminal Block
  9. Control Power indicator/fuse indicator light illuminates if control power is present in panel; alarm activates if control fuse is blown
  10. Alarm Power indicator/fuse indicator light illuminates if alarm power is present in panel (Not shown)
  11. Ground lugs
  12. Incoming pump power connections
  13. RF filter
  14. Power supply
  15. Control fuse
  16. Alarm fuse
  17. USB port for flash drive to download time-stamped system events
  18. Manual report switch date and time stamps service calls

Note: Options, voltage, and amp range selected may change enclosure size and component layout.

Note: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel.

INSTALLER FRIENDLY SERIES® IN-SITE® SINGLE PHASE DUPLEX – Demand or timed dose float controlled system for pump control, system monitoring, event logging and reporting.

Table 1

Table 2

9500060J-WEB Rev 01/23
© 2020 SJE, Inc. All Rights Reserved.
SJE Rhombus is a trademark of SJE, Inc

www.sjerhombus.com • Toll Free888-342-5753
B.25

California Prop 65 requires the following: WARNING Cancer and Reproductive Harm – wwW.P65Warnings.ca.gov
B.26
www.sjerhombus.com • email: customer.service@sjeinc.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SJE RHOMBUS User Manuals

Related Manuals