HEATIT 14 444 40 Z-Dim2 Z-Wave Plus Rotary Dimmer
INTRODUCTION
Heatit Z-Dim2 is a Z-Wave rotary dimmer for many different types of light
fixtures. The Heatit Z-Dim2 works on most low loads without causing
flickering. The dimmer is equipped with an external switch option. This allows
you to dim and turn on/off the load from an external switch. Heat it Z-Dim2 is
very well suited for LED, and fits into System 55 frames. When connecting low
loads it is recommended to use a bypass.
NB! DIMMING
Dimming may be challenging, and we recommend checking the compatibility of
different light sources before installation. We are happy to answer any
questions.
STATEMENT REGARDING PRODUCTS FROM MULTIPLE MANUFACTURERS
Please read this before installation
This device may be used with all devices certified with the Z-Wave Plus™
certificate and should be compatible with such devices produced by any
manufacturer. Every primary controller is different depending on the
manufacturer, their target audience and intended use/application. Please
review the functionalities implemented by the primary controller you intend to
use with our Z-Wave Plus certified device to ensure that it provides the
necessary controls to take full advantage of our product’s capabilities.
MOUNTING
WIRING DIAGRAM
QUICK START
- Switch off the mains voltage (turn off the fuse).
- Open the junction box.
- Connect according to the wiring diagram as shown above and in accordance with the main Installation manual Chapter 7.
- After verifying the connections, switch on the mains voltage.
- Set the primary controller in add mode (security/non-security).
- Press the reset button on dimmer 3 times in a rapid sequence. Heatit Z-DIM2 is now included in your Z-Wave network.
INSTALLATION AND WIRING
Installation must be done by a qualified electrical installer in accordance
with national building codes. Before installation, disconnect any power to the
dimmer mains. During the installation process, the fuse must be turned off AT
ALL TIMES!
NB! Max tightening torque for terminal screws: 2Nm
NB! This is a 2-wire dimmer so the Neutral is only connected to the load and not the dimmer itself.
- Turn off the fuse.
- Connect the Live to the dimmer terminal marked ”L”.
- Connect the load terminal marked ”L” to the dimmer terminal marked
- Install the dimmer (A) in the wall box. Make sure that no wires are pinched.
- Attach the cover (B) with the supplied nut (C).
- Attach the button (D) with a simple push.
ADD/REMOVE
Please read this before installation The primary controller/gateway has a mode for adding or removing devices. Please refer to your primary controller manual on how to set the primary controller in add/remove mode. The device may only be added or removed from the network if the primary controller is in add/ remove mode. When the device is removed from the network, it will NOT revert to factory settings.
Method 1: Standard (Manual)
Add/remove mode is indicated on the device by a blinking green LED. It
indicates this for 90 seconds until a timeout occurs, or until the module has
been added to/removed from the network. To start the configuration process
press the Reset button, or the external switch connected to P, 3 times in
rapid succession. The LED will blink green for 3 seconds if adding/removing is
successful. The device is now ready for use with default settings.
NB! When the device is removed from the gateway, the parameters are not reset. To reset the parameters, see Chapter 10 ”Factory reset” in the main installation manual. If inclusion fails, please perform a ”remove device” process and try again. If inclusion fails again, please see Chapter 10 “Factory reset” in the main installation manual.
LED blinking patterns
When device enters add/remove mode the LED will blink green. If successful,
the LED will blink green for 3 seconds. If unsuccessful, the LED will blink
red for 3 seconds.
CONTROLS
DIMENSION
FEATURES
- Z-Wave rotary dimmer
- 2-wire
- 5W – 250W LED
- Nemko certified
- Power metering
- SmartStart
- Firmware update (OTA)
- Overload protection
- Short circuit protection
- Surge protection
- Overheat protection
- External switch
- Min. dim level
- Max. dim level auto-calibration
- Supports encryption mode S0
- S2 Authenticated Class,
- S2 Unauthenticated Class
This product is a security-enabled Z-Wave Plus product with encryption. The product must be used with a security-enabled Z-Wave Controller in order to fully utilize the product.
TECHNICAL DATA
- Protocol Z-Wave, 868.4MHz
- Chip Z-Wave 700 chip
- Rated voltage 230VAC 50Hz
- Power 5W – 250W
- Controls Rotary and push dimming
- Ambient temperature 5°C to 40°C
- Range RF Min. 40 meter
- Connection Max. 2.5mm²
- Flush mounting depth 24mm
- IP Code IP 21
- Size (LxWxH) 84 x 84 x 43mm
- Approvals Z-Wave Plus V2, CE, Nemko
Working frequency 868.4MHz, Max output power 12,49dBm. The distance between the user and the products should be no less than 20 cm.
MAINTENANCE
The device is maintenance-free, but must never be covered. Only for indoor
installation.
Heatit Controls AB can not be held liable for typographical errors, other errors, or omittances in our information. Product specifications may change without further notice. All electrical installations must be carried out by a licensed electrician. The product must be installed in accordance with national building codes and our installers manual.
Heatit Controls AB l Läkarvägen 4, 454 31 BRASTAD, SWEDEN.
Phone: +47 61 18 77 77
post@heatit.com