GH 18-0 30KW Aku Hot Air Turbine
Please read the instructions carefully before starting the machine.
Scope of delivery
Assembly
Operation
Cleaning & Transport, Storage
EC Declaration Of Conformity
Technical Data
Gas fan heater | GH 18-0 30KW |
---|---|
Art. No | 58431 |
Device category | I3B/P |
Voltage | 18 V ⎓ |
Heat output | 18 – 30 kW |
Gas consumption | 1300 – 2180 g/h |
Power input Fan | 0,9 A |
Power consumption Fan | 17 W |
Fan power | 450 m³/h |
Degree of protection | IPX4 |
Connection hose | 1,5 m |
Type of gas | Propane (G31), Butane (G30) or mixtures thereof |
Size of gas cylinder | 5 kg |
Connection pressure range | 1 – 16 bar |
Operating pressure P (mbar) | 700 mbar |
Over-temperature protection | 95 °C |
Classification of the device according to air output temperatur | 63 K |
Air output temperature (1,5 m Distance) | 63 °C |
Destination countries | AT,CH,DE,DK,FI,IE,IT,NL,NO |
Dimensions L x W x H | 475 x 220 x 365 mm |
Net/gross weight | 4,6 kg / 6,8 kg |
Heat output
Heat output | Pnom | 30 kW |
---|---|---|
Minimum heat output (inactive) | Pmin | 18 kW |
max. Continuous heat output | Pmax | 30 kW |
Fuel
Select fuel | [gasförmig] | [G30] |
---|---|---|
Minimum heat output (indicative) | NOx | 120,41 [mg/kWhinput] (GCV) |
Additional power consumption
At rated output | elmax | #NAME? |
---|---|---|
At minimum output | elmin | #NAME? |
At minimum output | elSB | #NAME? |
Power requirement of pilot flame
ower requirement of pilot flame (if present) | Ppilot | 0 kW |
---|
Thermal efficiency (NCV)
At rated heat output | ηth, nom | 100% |
---|---|---|
At minimum heat output (Reference value) | ηth, min | 100% |
Type of heat output/room temperature control (select one)
Single-stage heat output without room temperature control | – |
---|---|
Two or more manual stages without room temperature control | x |
With room temperature control using mechanical thermostat | – |
With electronic room temperature control | – |
Electronic room temperature control with daily timer | – |
Electronic room temperature control with weekly timer | – |
Other control options (multiple selection possible)
Room temperature control using presence detection | – |
---|---|
Room temperature control using open window detection | – |
With remote control option | – |
With adaptive switch-on control | – |
With operating time limit | – |
With “Black Bulb” temperature sensor, black | – |
Space heating annual efficiency | ηs:91% |
Energy Efficiency Index | – |
Energy Efficiency Class | A |
(*)NO,= Nitric oxides
Read and understand the operating instructions before using the appliance. In
case of any doubts about connection and operation refer please to our customer
center
The product is designed for use by persons aged 16 or older. This appliance is
not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
Specified Conditions of Use The gas fan heater is designed for heating, drying
buildings and de-icing and must only be operated in well-ventilated rooms or
outdoors.
Ventilation openings of at least 750 cm2 must be available in the room where
the appliance is installed (at least 25 cm2 per 1 kW rated heat output).
The minimum room size must not be less than 300 m3 (1 m3 per 100 W rated heat
output).
The device must not be operated in environments or rooms below ground level.
It must not be used for heating habitable rooms in residential buildings; for
use in public buildings, observe national regulations.
This product is only suitable for occasional use. When using the device, the
respective local building andfire protection regulations must be observed. Do
not install the device in rooms at risk of explosions and fire. The apparatus
is not intended for drying of clothing or for installation under benches or in
floor trenches. Do not use the device in animal husbandry or animal breeding.
Please note that our equipment has not been designedfor commercial, craft or
industrial use.
If the equipmentis used in commercial, craft or industrial operation or for
similar activities, we cannot assume any liability. Do not use this product in
any other way as stated for normal use.
Not observing general regulations in force and instructions from this manual
does not make the manufacturer liable for damages.
The gas heater must not be used: For heating of closed or occupied rooms
(residential buildings) or operation in these areas; In the vicinity of
combustible materials (e.g. paper, building materials); An explosive
atmosphere may be created in places where volatile materials (e.g. gasoline,
solvents, chemicals) are stored or present; After an arbitrary structural
change in the gas heater; In case of wrong, unauthorised connection to a gas
source; In places that are not sufficiently ventilated; As a source of heat
for events and festivals.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified
medical attendance as quickly as possible. Protect the injured person from
further harm and calm them down. If you seek help, state the If you seek help,
state the following pieces of information following pieces of information
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Warning Read all safety warnings and all instructions.Failure to follow
the warnings and instructions may result in electric shock, fire and/or
serious injury.
Save all warnings and instructions for future reference.
Safety instructions for Gas fan heater
Caution – certain parts of the product may get hot enough to cause burns.
Particular caution is called for if children and persons requiring protection
are present.
The device must be disconnected from the gas cylinder after every use using
the gas cylinder shut-off valve!
Make sure that the fan is operating properly before igniting the burner.
Only use the device in a well-ventilated environment and away from combustible
materials.
The device must not be operated in environments or rooms below ground level.
Never operate/touch the device with wet hands.
Do not put foreign objects in the device.
Prevent any torsion stresses on the connection hose.
Do not use or store explosive or flammable materials (e.g. fuel, paper,
paints) in the vicinity of the product.
People are prohibited from being in the installation area at any time.
The safety distance on the air intake side must be 2.5 metres, on the air
outlet side 3.5 metres, to the side 2 metres and upwards 2 metres.
Do not move the device when it is in use.
Never place the gas cylinder in front of the gas fan heater when it is in use!
This is a fire hazard!
It must always be ensured that air can be taken in and vented freely.
The devices may not be used in atmospheres that contain oil, sulphur or salt.
Do not set up in rooms at risk of fire (e.g. wood sheds).
Protect the electrical parts from moisture. To prevent electrical shock, never
submerse these parts in water or other fluids during cleaning or when in
operation.
Never hold the apparatus under flowing water.
Switch off the device and disconnect it from the power supply before replacing
accessory parts, cleaning work and if it is not in use.
If the device has not been used for a longer period of time, the entire device
must be checked for correct functionality, including a leak test. A leak test
can be carried out with a leak detection spray or soapy water, for example.
Do not use this heater with a program switch, a time switch, a separate remote
control system or any other device that automatically switches the heater on,
as there is a risk of fire if the heater is covered or set up incorrectly.
Symbols
| Read the operating instructions to reduce the risk of injury.
---|---
| Take the replaceable battery horn the appliance before anyextension,
cleaning and servicing works.
| Warning / Caution!
| Warning against hot surfaces! Danger of burns!
| Keep distance of persons Observe to keep out of dangerous zone
| Caution! Danger: high voltage
| Pressure bottle to be secured by chain
| Keep dry at all times. Never expose tool to rain.
| Caution! Covering the device poses a fire hazard!
| Only use the device indoors.
| Open flames are prohibited
| Safety class Ill
| Operating pressure
700mbar| Gas valve
GAS| Fan
| Piezo ignition
| European Conformity Mark
| Any damaged or disposed electric or electronic devices must be
delivered to appropriate collection centres.
Operation
After you have read and understood the safety instructions. you may commission the device.
- Connect the pressure regulator to the gas cylinder valve.
- Connect the gas hose to the pressure regulator.
- Connect the gas hose to the heater.
- Open the gas cylinder valve.
- Check screw caps with leak detection spray or soapy water for possible gas leakage. Tighten again if necessary.
- Insert the battery.
- Press the On/off switch.
- From the intake side, check whether the fan is rotating.
- If the fan is turning, keep the gas valve button pressed and at the same time press the ignition button repeatedly until the burner ignites.
- Keep the gas valve button pressed for approx. 10 seconds.
- Check that the gas heater is running continuously.
- Use the control dial to adjust the heat output to the desired level.
Power off:
- To switch off the gas heater, always close the gas cylinder valve first.
- Run the fan for I .2 minutes to blow out any non• combusted gas and to cool down the unit.
- Switch the device off with the On/Off switch.
- Remove battery.
- Disconnect the device from the gas cylinder by unscrewing the pressure regulator from the gas cylinder valve.
An unpleasant smell may be produced when the device is used for the first
time in some cases. This is however completely harmless and will disappear
completely over time
Handling of gas bottles.
Make sure the gas bottles are used and stored in rooms with sufficient air
inlet and outlet. A leaking gas bottle may reduce the share of oxygen in the
inhaled air and therefore represent a risk of suffocation.
Before using the device, always check that the pressure controller seal is
correctly fitted and working properly.
Before use, make sure the gas bottle contains gas designed for the work being
done.
Gas bottles must always be safely fixed in a vertical position on a wall
support or on a specially manufactured gas bottle cart.
The liquid gas cylinder must be changed in a wellventilated room or outdoors,
and away from open flames (cigarettes, candles or other devices with open
flames).
The bottle with shielding gas and the fixed adjustment gas current equipment
must not be moved. The gas bottle valve must be closed during transport. Close
the gas bottle valve after use.
Smell of gas or suspect leakage
If you smell gas or suspect a leak, do not use the device. If the device is in
use, the gas supply must be shut off immediately. Immediately open windows and
doors. Do not press any electrical switches (e.g. light switches), do not use
a telephone or similar and do not use any naked flames or sources of ignition!
The device must be checked and any faults remedied before it can be used
again.
Emergency procedure
- Stop the gas supply to the device.
- Move out of the danger zone immediately and make sure that no other persons are in the danger zone.
- Call the fire brigade.
Maintenance
Take the replaceable battery from the appliance before any extension, cleaning
and servicing works.
Check the gas hose lines at least once a month as well as every time the gas
cylinder is replaced. If there are any signs of damage, the hose lines must be
replaced.
The entire device must be checked for correct func- tionality, including a
leak test, once a month. A leak test can be carried out with a leak detection
spray or soapy water, for example. Check the position of the ignition
electrodes after every 50 hours of use. There should be a gap of 5-7 mm.
After every 50 hours of use, check the position of the ignition electrodes and
check the connection between the temperature controller and the temperature
sensor for contamination. If dirty, clean with a cloth. Always switch off the
device if you cannot leave it in a safe state. Clean the fan blades and the
inside of the heater with compressed air every season or as needed. Repairs
and works specified in these instructions may only be performed by qualified
authorised staff. Use only original accessories and original spare parts.
Always keep the device clean, as well as the ventilation slots in particular.
Never spray water on the device body! Do not clean the plastics with solvents,
flammable or toxic fluids. For cleaning, use a damp cloth only. Only a
regularly maintained and treated appliance can serve as a satisfactory aid.
Insufficient maintenance and care can lead to unforeseen accidents and
injuries.
Storage
Always remove the battery and gas cylinder when the device is not in use or in
storage! Refer to the relevant chapters for instructions.
Store the device and its accessories in a dark, dry and frost free place,
which cannot be accessed by children.
The optimum storage temperature is between 5 and 30°.
Never store the liquid gas cylinder in environments or rooms below ground
level!
Never store liquid gas cylinders in unventilated places!
The gas cylinders must be fitted with valve protection caps and lock nuts when
stored.
Gas cylinders must always be stored upright! This also applies to empty gas
cylinders!
Warranty
Warranty period of 12 months applies to commercial use and 24 months applies
to private use and com- mences on the day of purchase of the device.
The guarantee solely covers inadequacies caused by material defect or
manufacturing defect. Original payment voucher with the sales date needs to be
submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised use such as appliance
overloading, use of violence, damage as a result of any unauthorised
interference or caused by foreign items. Failing to follow the ope-rating and
assembly instructions and common wear are also not included in the guarantee.
Important information for the customer
Please note that returns within or outside the warranty period should always
be in the original packaging. This measure effectively avoids unnecessary
transport damage and any associated disputed ruling. Your equipment is
optimally protected only in the original box, and keeping it in that box will
ensure smooth processing.
Service
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year f production. All this data can be found on the type label.
Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com
Failure removal
Transport packaging disposal
The packaging protects the machine against damage during transport. Packaging
materials are usually chosen based on environment aspects and waste treatment
principles and are therefore recyclable. Returning the packaging into material
circulation saves raw materials and reduces waste production. Parts of
packagings (e.g. foils, styropor®) can be dangerous for children. Do not
dispose of electrical appliances in household waste; use the local collection
points. Ask your local authority where the collection points are to be found.
If electrical equipment is disposed of in an uncontrolled manner, weathering
can lead to dangerous substances entering the groundwater and from there the
food chain, or the flora and fauna can be poisoned for years. If you replace
the device with a new one, the seller is legally obliged at the least to take
back the old one to be disposed of free of charge.
Risk of suffocation!
Keep parts of the packagings out of reach of children and dispose them as soon
as possible.
Error | Causes | Remedy |
---|---|---|
The motor does not start | No electricity | Charge theCharge the battery |
Use a fully-charged battery battery
Piezo-ignition does not ignite| Electrode in incorrect position| Call
specialist
No gas| Gas cylinder empty| Replace gas cylinder
Closed valve on the gas cylinder| Open valve
Gas hose or leaking connection| Seek for leaking point by suitable spray and
remove
Burner ignites, flame goes off as soon as the gas
valve is turned on| Thermal element not yet hot properly| Try again
Safty thermostat turned off| Let the device cool down and then retry
Burner flame goes off during operation| Excessive gas output| Have the
reduction valve checked or
replaced
Gas cylinder empty| Replace gas cylinder
Insufficient gas input| Check and clean motor grid Check fan
Wind or air draught extinguishes
flame| Place the device outside wind or air draught, let it cool down for
several minutes and then retry
Battery gas heater
58431 GH 18-0 30KW
Appropriate EU Directives Directives CE applicables
| 2014/35 EU| | 2014/30/EU
---|---|---|---
| 1935/2004/EC| | 1907/2006/EC
| 2011/65/EU&2015/863EU| | 2016/426/EU
| 2016/425/EU (PPE)| | 2019/1784/EU
| 2015/1188/EU| | 2014/29/EU
| 2006/42 EC| | 97/68/EC_&2016/1628/EU
Emission No.:
| Annex IV
Notified Body Name:
No: Adress:
Type Ex. Cert.-No.:| | 2000/14/EC_2005/88/EC
Method of compliance assessment
Harmonised standards used
EN 1596:1998+A1:2004; EN 60335-1:2012+A11+A13+A14
EN 60335-2-102:2016
EN 62233:2008; EN 62321
EN 55014-1:2017
EN 55014-2:2015
EN IEC 61000-3-2:2019
EN 61000-3-3:2013+A1
Guaranteed sound power level
Lwa dB (A)
Measured sound power level
Lwa dB (A)
Annex VI ****
Managing Directo
Authorized to compile the technical file
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com
References
- Güde | Maschinen & Werkzeuge für den Hand- & Heimwerker
- Güde | Maschinen & Werkzeuge für den Hand- & Heimwerker
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>