HANYOUNG nux PEN-T10A Photo Sensor Instruction Manual
- June 12, 2024
- HANYOUNG NUX
Table of Contents
Photo Sensor
PEN series
INSTRUCTION MANUAL
Thank you for purchasing Hanyoung Nux products.
Please read the instruction manual carefully before using this product, and use the product correctly.
Also, please keep this instruction manual where you can see it any time.
Safety information
Please read the safety information carefully then use the product correctly.
The alerts declared in the manual are classified into Danger, Warning and
Caution according to their importance
DANGER| Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury
---|---
WARNIN| Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury
CAUTION| Indicates a potentially hazardous situation which, if not
avoided, may result in minor injury or property damage
DANGER
- The input/output terminals are subject to electric shock risk.
Never let the input/output terminals come in contact with your body or conductive substances.
Warning
- Users must attach the safety device twice when using the product with the machines which may cause casualties, mass damage to the assets or etc since it is not designed as the safety device.
- Please supply in the proper power supply voltage accordance to the rating in order to prevent the product from breaking down or damage.
- Please detach the device after turning off the power. Not doing so may cause an electric shock, malfunction or breaking the device
- Do not disassemble, manufacture, upgrade or fix the product. There are possibilities of malfunction or electric shock or fire to occur.
Caution
-
Please do not use auto-trans in order to maintain the safety of power supply voltage of the product.
Please use the insulation trans. -
When extending the cable, please use thick wire (at least thickness 0.3 ㎟) and at this moment, please watch out for the voltage-drop •Please separately wire the high-tension wire/power line from the sensor.
-
Turning the power ON/OFF continuously will shorten the life expectancy of the product or may cause the malfunction so please be cautious
-
When cleaning the lens and the case, please use a dry cloth and gently wipe the surface. You must not use solvents such as thinner or alcohol.
-
When setting the sensitivity, do not actuate the sensitivity volume with the strong force on it. Doing so may break the volume.
-
When using the power supply device (SMPS), users must earth the frame ground (F.G) terminal.
Not doing so may cause malfunction due to the switching noise of the power so please be cautious
Specification
Model | Power built-in type |
---|---|
PEN-710A | PEN-M5A |
Detection method | Through – beam |
Detection range | 10 m |
Sensing object | Opaque object above 020 mm |
non-glossy paper 200 x 200 mm
Power supply voltage| 24 – 240 VDC/AC (Dual usage) ±10 % 50/60 Hz
Power consumption
(current)| transmitter| 1 W max| 2 W max
receiver| 2 W max
Operation mode| Light ON / Dark ON X selected by the mode volume
Sensitivity adjustment| –| Built-in the sensitivity adjustment volume
Control output| Relay contact output (lc) 30 VDC 5 A / 250 VAC 5 A (resistive
load)
Electrical life expectancy : min 100,000 times
Response time| 20 ms max
Hysteresis| –| Within the 20% of the detection range
Light source| Infrared ray LED (850 nm)
Indicator| Output indication : Red LED (In case of the transmitter, red
indicates the power state), Stability: Green LED
Ambient illumination| Sunlight : 11,000 Lux max, Incandescent lamp : 3,000 Lux
max
Ambient temperature| During operation : -20 – 60 C, During storage : -25 – 70
C (Without condensation))
Ambient humidity| 35 – 85 % R.N. (Without condensation))
Degree of protection| IP 64 (IEC)
Insulation resistance| 20 MD min (500 VDC mega between the recharging part and
case)
Dielectric strength| 1,500 VAC (50/60 Hz 1 minute)
Vibration resistance| 10 – 55 Hz 1.5 mm double amplitude for 2 hours each in
X, Y and Z directions (but when power is OFF)
Shock resistance| 500 mg (Approx. 50 G), 3 times each in X, Y and Z directions
Connection method| Cable extended type (it of cables : 5P, diameter : 0 6 mm,
length : 2 mm) X but transmitter is 2P
Material| Case : heat resistant ABS, Lens: PC
weight(g)| 150
Cautious 1) the sensing distance can be varied depending on the size, surface condition, glossy, non-glossy of the sensing object.
Connection diagram
- Through-beam type is limited to the receiver
Dimension
■ Outer dimension
■ Reflector (HY-M5)
■ Bracket mounted
Output operation characteristic
Installation
- Through-beam type
NO | Method | Picture | Output mode |
---|---|---|---|
1 | Supply in the power after placing the transmitter and receiver face to face | ||
each other. | Dark ON fixed | ||
2 | Fix either the transmitter or receiver and check for the range where the |
operation indicator becomes turned ON or turned OFF by controlling in the
direction of up, down, left and right. After finishing the confirmation, place
it in the middle and fix it.|
3| Place the sensing object within the setting range and confirm the condition
of proper operation.|
- Retro-reflective type
NO | Method | Picture | Output mode |
---|---|---|---|
1 | Supply in the power after placing the sensor and mirror face to face each | ||
other in the straight line. | Dark ON | ||
2 | Fix either the sensor or mirror and check for the range where the operation |
indicator becomes turned OFF by controlling in the direction of up, down, left
and right.
After finishing the confirmation, place it in the middle and fix it.|
3| Place the sensing object within the setting range and confirm the condition
of proper operation and once the confirmation is finished, fix the sensor.|
■ Diffuse-reflective type
NO | Method | Picture | Sensitivity Volume | Output mode |
---|---|---|---|---|
1 | After removing the sensing object, turn sensitivity volume gradually to the |
max direction and once indicator lights up, that position will be referred as
‘A’.
(If indicator does not get turned ON (OFF) even in the position of maximum set
on the max position.)| | | Light ON
2| Place the sensing object in the desirable setting position and gradually
turn the sensitivity volume from ‘A’ to the , gradually
min direction and once the indicator gets to turned ON (OFF) than that
position will be referred as t’.| |
3| Place the sensitivity volume in the middle of max and ‘A’ or ‘B’ and
confirm the operation condition of sensing object that occurs within the
setting range.| |
References