ADA VUPPA-II S Water Surface Extractor Instruction Manual

June 12, 2024
ADA

ADA VUPPA-II S Water Surface Extractor

Before using

  • Before installing this product, read this instruction manual carefully and follow all instructions. Do NOT attempt to use this product without understanding its proper use.
  • Keep this instruction manual and refer back to it when needed.
  • ADA is not responsible for any accident, breakage or breakdown caused by improper usage of this product.
  • Do NOT operate a Submersible pump exposed in air. A Submersible pump must be turned on under water.
  • Make sure that this product operates properly at the beginning of use or when restarting, such as after a power failure.
  • This product is not intended for use in saltwater.
  • Do NOT give a strong impact to or drop this product.
  • A small fish or shrimp can get inside of the pump from the top or the slit. If a small fish or shrimp becomes trapped inside, pull the USB power adapter out from the electrical outlet and turn off the pump immediately, and rescue the trapped fish or shrimp.
  • ADA will not be held responsible for a disease or the death of a living organism

Safety instruction

Caution :Improper use of this product can result in serious injury or property damage

  • Plug the USB power adapter securely into an outlet. Do NOT use the USB power adapter where it can be splashed with water droplets or in a highly humid or dusty area.
  • Do NOT touch the USB power adapter with wet hands. It may cause an electrical shock.
  • Unplug the USB power adapter from an outlet when not in use.
  • Connect the USB power adapter and the USB connector properly.
  • While this product is rated for 50Hz-60Hz, it requires the proper power-supply voltage. Improper usage can result in fire, a short circuit, and/or electrical shock.
  • Do NOT handle roughly or damage the electrical cord. A damaged cord may cause fire, a short circuit, and/or electrical shock.
  • Do NOT modify the Submersible pump or install a toggle switch on the cord. It may result in malfunction or a serious accident.
  • Although the product is finished carefully, special care should be given to avoid a possible injury when handling the product since an edge of a stainless steel part may be sharp or there might be a burr on a strainer.
  • When turning off the Submersible pump, pull the USB power adapter out from the electrical outlet. Do NOT pull the USB connector out of the USB power adapter.
  • KEEP OUT OF REACH OF CHILDREN

Special features of VUPPA-Ⅱ

VUPPA-Ⅱ effectively eliminates oil, organic matter, and dust that sometimes form a thin film on the aquarium water surface. It adopts float switch that makes water level adjustment unnecessary and prevents cavitation. Its superior design of stainless housing does not spoil scenery of Nature Aquarium but fits to it naturally. It also can function as an internal filter in smaller tank.

Parts

Please confirm all supplied parts are included before use.

ADA-VUPPA-II S-Water-Surface-Extractor-FIG-1ADA-VUPPA-II S-Water-Surface-Extractor-FIG-2

Parts of Submergible pump

Usage

VUPPA-Ⅱ is a ready-to-use product. No assembly required Installation in an aquarium (This product can be installed to frame-less tank with glass thickness below 15mm)

  1. Loosen the Set screw to retract the Mounting bracket B. Take care not to let the VUPPA-Ⅱ collide with the glass surface of an aquarium.
  2. Hang VUPPA-Ⅱ on the aquarium and adjust the Mounting bracket B to fit the glass thickness.
  3. Hold the Mounting brackets A and B against the glass surface and tighten the Set screw with a flathead screw driver.
  4. Slide VUPPA-Ⅱ upward or downward to position the top part of VUPPA-Ⅱ at the water surface.
  5. Make sure the product is submerged in aquarium water and plug the USB power adapter into an outlet. Do not operate the Submersible pump in air to avoid damage to the pump.

Caution

  • The water surface of an aquarium moves up and down due to evaporation or through a water change. This product can adjust the water level within 3cm maximum by itself, thereby water adjustment is unnecessary in this range. However, if the water level gets lower and the dropped water decreases, it weakens the ability to remove the surface oil film. When the water level decreases and gets near the end of slit, please either add water in the tank or slide the product down.
  • This product makes clicking sound when activated. It comes from the Float switch and is not abnormal.
  • Floating type fish food may be sucked into the filter section from the slits.
  • Remove any object sticking to the slit, such as plant pieces, immediately.
  • Small aquatic fauna may get trapped inside the product. If this occurs frequently, it is recommended to use this product only when required, depending on the aquarium’s water conditions. ADA will not be held responsible for any loss or damage to living organisms.
  • If the product is to be stored for a while, wipe the product dry using a dry cloth and remove any moisture from the inside. Although this product is made of highly corrosion-resistant stainless steel and treated with a rust inhibitor, it may rust depending on the usage or storage condition

Maintenance

  • Remove any detritus accumulated in the Filter sponge as soon as possible. When washing the Filter sponge, remove the sponge with tweezers from VUPPA-Ⅱ and rinse it lightly with aquarium water in a plastic container.
  • Water flow will decrease if an object is caught inside the Submersible pump or if the Impeller becomes dirty. If this occurs, detach the Cover and remove the object or clean the Impeller with a brush.
  • If the Submersible pump needs to be separated from the body of VUPPA-Ⅱ, remove the Outflow pipe and pull out the inner parts. The Submergible pump is attached to the inner parts with suction cups. Do not apply unnecessary force when removing the pump. It may damage the pump. Do not remove by pulling on the electrical cord, so as not to damage the cord and the equipment.
  • Float switch is a very fragile part. Do not drop or damage during maintenance. It may cause malfunction.
  • When cleaning the Submergible pump, Cover need to be removed. Both parts are easy to detach.
  • After the maintenance of the Submersible pump, please put the parts back properly. When assembling the inner parts and outer case, make sure not to tuck cords in and damage
  • If it is difficult to attach the Outflow pipe, the Submersible pump’s outlet and the outlet hole on the stainless steel housing may not be properly in place. Match the position of the holes with the tip of a screwdriver or other tools, and insert the Outflow pipe

ADA

0256-72-1994(平日10:30~17:30)

E-mail /support@adana.co.jp

8554-1 Urushiyama, Nishikan-ku, Niigata 953-0054, Japan Canister/MADE IN JAPAN