INSTRUCTIONS
Fire Rated Wafer Downlight FA FWAFER4/ FWAFER6
FWAFER4B/ FWAFER6B
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
RAB fixture must be wired in accordance with the National Electrical Code and
all applicable local codes. Proper grounding is required for safety. THIS
PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
TO PREVENT ELECTRICAL SHOCK, POWER SHOULD BE TURNED OFF AT THE FUSE BOX BEFORE
INSTALLATION.
SAFETY WARNINGS:
Read all product labels and directions.
- WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the inputrating of the luminaire.
- Installation should be performed only by a qualified electrician in accordance with the National Electrical Code and relevant local codes. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- INSTALLATION SHOULD ONLY BE PERFORMED AFTER POWER TO THE FIXTURE HAS BEEN DISCONNECTED.
- These instructions shall be included on an information sheet packaged with each unit.
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
WHAT’S IN THE BOX
TOOLS NEEDED
This Fire Rated Wafer requires very few tools for installation.
A screwdriver and a pair of wire cutters will help to install.
OPTIONAL ACCESSORIES (sold separately)
EXTCBL-FA-6
Wafer extension cable 6ft
EXTCBL-FA-12
Wafer extension cable 12ft
EXTCBL-FA-20
Wafer extension cable 20ft
INSTALLATION INSTRUCTIONS
- Turn power OFF from the electrical panel before installation.
- Use template inside box to cut hole in ceiling. (Fig.1)
- Open the driver box and remove the knockout(s). (Fig.2)
- Insert the electrical supply cable through the knockout and secure with a terminal. Wire driver box (Fig.3) , white-white, black – black, green – green/ground.
- Place all wiring and connections back into the box, close the cover and select desired CCT. (Fig.4) INSTALLATION INSTRUCTIONS (cont’d)
- Place the driver box into the ceiling and connect the fixture to driver box. (Fig.5)
- Lifting both retention tabs upward. Push until the trim sits flush against the ceiling. (Fig.6)
Note: These instructions do not cover all details or variations in
equipment nor do they provide for every possible situation during
installation, operation or maintenance.
RAB Lighting is committed to creating high-quality, affordable, well-designed
and energy-efficient LED lighting and controls that make it easy for
electricians to install and end users to save energy. We’d love to hear your
comments. Please call the Marketing Department at 888-RAB-1000 or email:
marketing@rablighting.com
©2023 RAB LIGHTING Inc.
Cranbury, New Jersey 08512 USA Fire Rated Wafer Downlight FA
Easy Answers
rablighting.com Visit our website for product
info
Tech Help Line
Call our experts: 888 722-1000
e-mall Free Answered promptly
–sales@rablighting.com
Lighting Layouts
Answered online or by request
RAB WARRANTY: MB’s warranty is subject to oil terms and conditions found
atroblighting.com/wortonty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>