DZS 2466GN Edge Subscriber Installation Guide

October 30, 2023
DZS

DZS 2466GN Edge Subscriber

DZS-2466GN-Edge-Subscriber-PRODUCT-IMG

Product Information

The 2466GN is an indoor-use unit designed to provide internet and VoIP services. It has an uplink interface, a service interface, and a VoIP interface. The unit comes with a quick installation guide and a power adapter. The operating temperature and humidity range is not specified in the manual, but it is recommended to use the unit in dry rooms and away from direct sunlight or other electrical equipment. To ensure proper usage, it is important to follow the caution and warning guidelines provided in the manual.

Product Usage Instructions

Wall Mounting with Fiber Tray

  1. Mount a fiber tray on the wall.
  2. Wrap extra fiber around the fiber spools in a counterclockwise direction, making sure there is enough flexibility for the fiber to connect to the 2466GN without bending the fiber tighter than a 30 mm radius.
  3. Attach the 2466GN to the fiber tray.
  4. Connect the optic cable to the GPON port.

Web Access

To access the unit through a web browser, follow these steps:

  1. Connect an Ethernet cable from your computer to GE1 on the 2466GN.
  2. Launch a browser or telnet session and point it to 192.168.1.1 TEhnetedr ethfaeuultsuesrnearnmaemaen/pdapsaswssowrdorids.admin/dzs.i
  3. For security reasons, change the default password.

Caution and Warning Guidelines

Please follow these instructions to avoid physical injury:

  • Do not install the unit during a storm.
  • Do not connect or disconnect any line to avoid the risk of electric shock.

Other important guidelines to ensure proper usage:

  • The unit is for indoor use only and all communication wirings should be limited to inside the building.
  • Do not plug in, turn on, or attempt to operate an obviously damaged unit.
  • Never look directly at the fiber TX port and fiber cable ends when they are powered on.
  • Do not use near water or high-temperature sources.
  • Do not disassemble the unit.
  • Do not operate the unit in a location where the maximum ambient temperature exceeds 40°C.
  • Before making connections, use isopropyl alcohol and non-fibrous cellulose to clean the faces of the connectors.
  • Avoid impact stresses when handling connectors. Physical damage to the faces of optical connections impairs transmission quality (higher attenuation).
  • Avoid a bend radius in excess of 30 mm for fiber optic links.
  • Check the available voltage supply.
  • Only use the unit in dry rooms.
  • Set up the unit away from direct sunlight or other electrical equipment.
  • Only connect approved accessories.
  • The unit may only be repaired by authorized service personnel.
  • This equipment is not suitable for use in locations where children are likely to be present.

Product Limited Warranty

The warranty does not cover defects and damages resulting from product disassembly. Such behavior may also amount to intellectual property infringement.

Wall mount when using a fiber tray

  • If necessary, you may have your ONT mounted on a wall using a fiber tray.

DZS-2466GN-Edge-Subscriber-FIG-1

  1. Mount a fiber tray.
  2. Wrap extra fiber around the fiber spools in a counterclockwise direction, making sure there is enough flexibility for the fiber to connect to the 2466GN without bending the fiber tighter than a 30 mm radius.
  3. Attach the 2466GN to the fiber tray.
  4. Connect the optic cable to the GPON port.

Web Access

You can access the unit through a web browser by using the following steps:

  1. Connect an Ethernet cable from your computer to GE1 on the 2466GN.
  2. Launch a browser or telnet session and point it to 192.168.1.1
  3. Enter the username and password.  The default username/password is admin/dzs. i For security the password should be changed.

Information furnished by DZS is believed to be accurate and reliable. However, no responsibility is assumed by DZS for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of DZS. DZS reserves the right to change specifications at any time without notice.

Caution

Please follow the instructions below to avoid physical injury: You should not install the unit during a storm. Likewise, you should not connect or disconnect any line to avoid the risk of electric shock.

Caution & Warning

  • This unit is indoor use and all the communication wirings are limited to inside of the building.
  • DO NOT plug in, turn on or attempt to operate an obviously damaged unit.
  • Never look directly at the fiber TX port and fiber cable ends when they are powered on.
  • DO NOT use near water.
  • DO NOT place near a high-temperature source.
  • DO NOT disassemble the unit.
  • DO NOT operate the unit in a location where the maximum ambient temperature exceeds 40°C.
  • Open optical connections must use a protective cap under all circumstances to protect against physical damage and dirt.
  • Before making connections, use isopropyl alcohol and non-fibrous cellulose to clean the faces of the connectors.
  • Avoid impact stresses when handling connectors. Physical damage to the faces of optical connections impairs transmission quality (higher attenuation).
  • Avoid a bend radius in excess of 30 mm for fiber optic links.
  • Check the available voltage supply.
  • Only use the unit in dry rooms.
  • Set up the unit away from direct sunlight or other electrical equipment.
  • Only connect approved accessories.
  • It may only be repaired by authorized service personnel.
  • This equipment is not suitable for use in locations where children are likely to be present.

Limited Warranty

  • Not covered under this warranty is defect and damage resulting from product disassembly by yourself. And also, such behavior may amount to intellectual property infringement.

Introduction

Package Contents

  • 2466GN
  • QIG (Quick Installation Guide)

Specification

Item Specification

  • Uplink Interface: 1 GPON port (SC/APC)
  • Service Interface: 4 10/100/1000Base-T ports (RJ45)
  • VoIP Interface: 2 FXS ports (RJ11)
  • Power Adapter: Output: DC12V/2A
  • Operating Temp: 0 to 40°C (32 to 104°F)
  • Operating Humidity: 5 to 95% (non-condensing)

Dimensions

Interface

DZS-2466GN-Edge-Subscriber-FIG-3

Item Description

  1. WPS: Enable the WPS process.
  2. RESET button: Reboot the unit.
  3. UPS: Power connector and UPS backup power.
  4. Power port: Connect an external power supply.
  5. USB: Connect an external 3.0 USB drive.
  6. POTS 1-2: Connect to VoIP phone.
  7. GE 1-4: Connect to PC or LAN. 4 10/100/1000Base-T interfaces.
  8. Fiber Connector: Connect optical network.
  9. LEDs: Operating status LEDs.

LED

DZS-2466GN-Edge-Subscriber-FIG-4 DZS-2466GN-
Edge-Subscriber-FIG-5

Installation

DZS-2466GN-Edge-Subscriber-FIG-6

  1. Remove the fiber service cover to expose the GPON port.
  2. Connect fiber optic cable with SC/APC termination to the GPON port.
  3. Re-attach the fiber service cover onto the 2466GN.
  4. Connect the telco cable from the POTS port to the home phone lines.
  5. Connect the Ethernet cable from the GE port to the PC.
  6. Connect the power cable from the power port to an electrical outlet.
  7. (OPTIONAL) Connect the Battery Backup Unit power and telemetry to the UPS port.

UPS Connector Pinouts

DZS-2466GN-Edge-Subscriber-FIG-7

Pin Signal Comments

  1. +VDC: Power in from UPS
  2. -VDC: Power return to UPS
  3. On Battery: Open signal when on battery power
  4. Signal Return: Connected to Signal GND on ONT
  5. Missing Battery: Open signal when battery not detected
  6. Replace Battery: Open signal when the battery should be replaced
  7. GND: Connected to Signal GND on ONT
  8. Low Battery: Open signal when the battery is low

Mounting on a Wall

  • If necessary, you may have your ONT mounted on a wall using mounting holes.

DZS-2466GN-Edge-Subscriber-FIG-8

FCC STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

INDUSTEY CANADA STATEMENT

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. In addition, this device complies with ICES-003 of the Industry Canada (IC) Rules. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Industry Canada license-exempt RSS standard(s). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

Copyright 2022 ⓒ DZS, Inc. All Rights Reserved.