DZS 2428GN Advanced Media User Manual
- June 15, 2024
- DZS
Table of Contents
V1.0
Quick Installation Guide
2428TE
Copyright 2022 c DZS, Inc. All Rights Reserved.
1. Caution
Please follow the instructions below to avoid physical injury:
You should not install the unit during a storm. Likewise you should not
connect or disconnect any line to avoid the risk of electric shock.
Caution & Warning
– This unit is indoor use and all the communication wirings are limited to
inside of the building.
– DO NOT plug in, turn on or attempt to operate an obviously damaged unit.
– Never look directly at the fiber TX port and fiber cable ends when they are
powered on.
– DO NOT use near water.
– DO NOT place near high temperature source.
– DO NOT disassemble the unit
– DO NOT operate the unit in a location where the maximum ambient temperature
exceeds 40°C.
– Open optical connections must use a protective cap under all circumstances
to protect against physical damage and dirt.
– Before making connections, use isopropyl alcohol and non-fibrous cellulose
to clean the faces of the connectors.
– Avoid impact stresses when handling connectors. Physical damage to the faces
of optical connections impairs transmission quality (higher attenuation).
– Avoid a bend radius in excess of 30 mm for fiber optic links.
– Check the available voltage supply.
– Only use the unit in dry rooms.
– Set up the unit away from direct sunlight or other electrical equipment
– Only connect approved accessories.
– It may only be repaired by authorized service personnel.
– This equipment is not suitable for use in locations where children are
likely to be present
Limited Warranty
– Not covered under this warranty is defect and damage resulting from product
disassembly by yourself. And also, such behavior may amount to intellectual
property infringement.
2. Introduction
2.1 Package Contents
– 2428TE
– QIG (Quick Installation Guide)
2.2 Specification
Item | Specification |
---|---|
Service Interface | 4 10/100/1000Base-T ports (RJ45) |
1 2.5GBase-T port (RJ45)
Wi-Fi| Wi-Fi6 Internal antenna
VoIP Interface| 2 FXS ports (RJ11)
Power Adapter| Output: 12VDC/2.5A
UPS| Output: 12VDC/2.5A
Operating Temp.| 0 to 40°C (32 to 104°F)
Operating Humidity| 5 to 95% (non-condensing)
Dimensions| 182 x 263 x 75 mm (Wx H x D)
2.3 Interface
Item | Description |
---|---|
1 | LEDs |
2 | USB |
3 | TEL 1-2 |
4 | GE 1-4 |
5 | 2.5GE |
6 | WPS button |
7 | Reset button |
Press and hold for 10 seconds to reset factory defaults.
8| UPS| Power connector and UPS backup power
9| Power port| Connect an external power supply.
10| On/Off button| Turn on/off the unit
2.4 LED
Label | Light | Status | Definition |
---|---|---|---|
5.8G | Blue | ON | 5GHz WiFi service is enabled on ONT. |
Slow Blink ( 1 / sec ) | 5GHz WiFi data passing between ONT and connected |
devices
OFF| 5GHz WiFi service is disabled on ONT.
2.4G| Blue| ON| 2.4GHz WiFi service is enabled on ONT.
Slow Blink (1 /sec)| 2.4GHz WiFi data passing between ONT and connected
devices
OFF| 2.4GHz WiFi service is disabled on ONT.
USB| Blue| ON| USB is connected.
OFF| USB is not connected.
VOICE| Blue| ON| Registered successfully
Slow Blink (1/sec)| Off hook
OFF| Registration failed or telephone service is not provisioned.
GE1-4/2.5GE| Blue| ON| Ethernet interface linked
Flash| Data transmitting
OFF| Ethernet interface not linked
INTERNET| Blue| ON| Internet service is available.
OFF| Internet service is unavailable. (no response from DNS server)
WAN| Blue| ON| Ranged successfully
Flash| Ranging in progress
OFF| Not ready for ranging or not provisioned
ALARM| Red| OFF| No major alarms
ON| Major Alarm (including operating in battery power)
Slow Blink (2 / sec)| SW or Config update in progress
BATT| Yellow| OFF| Normal operation on AC source
ON| Operating on Battery Power
Slow Blink (2 / sec)| Battery Alarm (Low Battery, Missing or Replace)
STATUS| Blue| OFF| Power off
ON| Normal Operation
Rapid Blink (10/sec)| Unit has been reset to factory defaults / is
unconfigured.
Slow Blink| Boot-up/ Initialization/ provisioning in progress
3. Installation
(1) Attach the 2428TE to the desktop stand in the direction of the marked arrow.
(2) Connect the telco cable from POTS port to home phone lines.
(3) Connect the Ethernet cable from GE port to PC.
(4) Connect the power cable from power port to an electrical outlet.
(5) (OPTIONAL) Connect the Battery Backup Unit power and telemetry to the UPS
port.
UPS Connector Pinouts
Pin | Signal | Comments |
---|---|---|
1 | +VDC | Power in from UPS |
2 | -VDC | Power return to UPS |
3 | On Battery | Open signal when on battery power |
4 | Signal Return | Connected to Signal GND on ONT |
5 | Missing Battery | Open signal when battery not detected |
6 | Replace Battery | Open signal when battery should be replaced |
7 | GND | Connected to Signal GND on ONT |
8 | Low Battery | Open signal when battery is low |
Mounting on a Wall
If necessary, you may have your ONT mounted on a wall using mounting holes.
- Mounting Holes
4. Web Access
You can access the unit through a web browser by using the following steps:
- Connect an Ethernet cable from your computer to GE1 on the 2428TE.
- Launch a browser or telnet session and point it to 192.168.1.1
- Enter the username and password.
The default username/password is admin/dzsi
For security the password should be changed.
Information furnished by DZS is believed to be accurate and reliable. However, no responsibility is assumed by DZS for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of DZS. DZS reserves the rights to change specifications at any time without notice.
FCC Regulations:
This mobile router complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This mobile router has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiated
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
FCC Note:
Caution: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
RF Exposure Information
This device meets the government’s requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government.
This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20 cm during normal operation.
ISED Notice
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
CAN ICES-003 (B)/NMB-003(B)
This Class B digital apparatus complies with Canadian ICES-003.
ISEDRF Exposure Statement
This device complies with ISED RSS-102 RF exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the IC RSS-102 RF exposure limits, human proximity to the antenna shall not be less than 20 cm during normal operation.
The device is restricted to indoor use only when operating in the 5150 to 5250 MHz frequency range.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>