FUJIFILM DAY-NIGHT Series Fujinon Day and Night Stabiscope Instruction Manual
- October 30, 2023
- Fujifilm
Table of Contents
DAY-NIGHT Series Fujinon Day and Night Stabiscope
Product Information: FUJINON DAY & NIGHT STABISCOPE
The FUJINON DAY & NIGHT STABISCOPE is a high-powered, internally gyro- stabilized binocular that combines fully-coated, computer-designed optics with a patented high-speed internal gyro-stabilized system. The product is designed for long-range observation, identification, tracking, and surveillance. It is the world’s first high-powered, internally gyro-stabilized binocular that has been proven on land, sea, air, and even in space on NASA shuttle missions. The binoculars have a day-use eyepiece lens that can be replaced with a night-use eyepiece lens, which has an image intensifier tube installed to provide a stabilized and bright image even in the deep dark.
Product Usage Instructions
The FUJINON DAY & NIGHT STABISCOPE is a versatile product that can be used
for various purposes. Here are some usage instructions:
Operating Instructions
To operate the FUJINON DAY & NIGHT STABISCOPE:
- Turn on the product by switching it to the ON position.
- Adjust the focus by turning the focus ring until the image is clear.
- Use the LOCK button to lock the image in place for stable viewing.
- Replace the day-use eyepiece lens with the night-use eyepiece lens to use the image intensifier tube.
- Use the DC power source to power the product.
Advantages
The FUJINON DAY & NIGHT STABISCOPE has several advantages:
- Internally gyro-stabilized for stable viewing
- Combines fully-coated, computer-designed optics for clear images
- Patented high-speed internal gyro-stabilized system
- Ultimate optical instrument for long-range observation, identification, tracking, and surveillance
- Can be used on land, sea, air, and in space
- Night-use eyepiece lens with an image intensifier tube for bright and stabilized images in the dark
Overall, the FUJINON DAY & NIGHT STABISCOPE is a reliable and versatile product that can be used for various purposes, including long-range observation, identification, tracking, and surveillance.
DAY & NIGHT STABISCOPE Advantages
The DAY & NIGHT STABISCOPE, the world’s first high powered, internally gyro-
stabilized binocular has been proven on land sea, air and even in space… on
NASA shuttle missions. Combining fully-coated, computer-designed optics with a
patented high speed internal gyro-stabilized system, the DAY & NIGHT
STABISCOPE is the ultimate optical instrument for long range observation,
identification, tracking and surveillance.
With replacing a day use eyepiece lens to a night use eyepiece lens in which
the image intensifier tube (I/I tube) are installed, stabilized and bright
image can be provided even in the deep dark nothing to look with naked eyes.
(The I/I tube can amplify the captured light to several ten thousand times
strength.)
By stabilized only the high powered optics (not the entire device), weight is
held to a minimum while the image remains steady and clear—free from the
effects of normal body tremor as well the motion aboard boats, aircraft and
land vehicles. The result is increased operator accuracy with less fatigue.
The new waterproof DAY & NIGHT STABISCOPE S1240 is lighter, more efficient and
more flexible and easier to use. They operate on their own AA batteries or
from an external 12-32 V DC source. In addition, the STABISCOPE can now be
operated comfortably right handed or left-handed. That is because it works
right side up and upside down. All that’s needed is simply reversing the
location of the hand strap. Incidentally, when the power switch is turned off
, the STABISCOPE may also be used as a conventional binocular.
STABISCOPE Features
Operating Instructions
Battery Installation
- Turn the open-close lever in the direction of the arrow mark and open the battery cover. (Fig. 2)
- When inserting 4 AA batteries (SUM-3), be sure they are installed as shown, (Fig. 3) with the positive + terminals facing the proper direction.
- When using lithium battery (type 2CR5), insert them in the direction of the slot, as shown. Be sure to keep the contact side of the batteries facing towards the back. (Fig. 4)
- While pressing the battery cover, turn the open-close lever toward the “LOCK” position until you hear a clicking sound. (Fig. 5)
Battery Life and Uses
-
Alkaline manganese size “AA” dry batteries will permit about 2-hours of continued use; lithium battery will allow approximately 5-hours of continued use. (Battery endurance drops by about 20% when a night use eye-piece is attached.)
Please note that lithium battery cost more, but they are lighter and offer greater resistance against low temperatures. -
Do not use a different type of battery and mixture of new and used batteries.
Main Switch
- Gently press the main switch. A green LED will light and the gyro motor will start to rotate. (Fig. 6)
- Wait for about a minute until the gyromotor reaches operating speed.
Lock Lever
- When operating the STABISCOPE with your left hand, raise the lock lever in the direction of the arrow mark, as illustrated; when operating with your right hand, lower it in the direction of the arrow mark. When the lock lever is released, the target can be observed without vibration or shakiness of the image. (Fig. 7)
- As described in the condition of 1 above, when the lock lever is released, a red LED positioned by the lock lever will light.
- The red will blink on· and off if the lock lever is released while the main switch is in the off position. Be careful not to let this condition continue for a long period.
CAUTION!
When observation is not being performed or when the gyro motor is not
rotating (when the main switch is OFF), keep the lock lever in the “LOCK”
position. Please be careful not to carry the STABISCOPE when the lock lever is
released : such action may result in problems.
Interpupillary Distance Adjustment
-
Since the distance between the left and right eyes varies from person to person, in order to see comfortably while using the STABISCOPE, the distance in between the two eyepieces should be adjusted. This can be done quickly and simply allowing anyone to use the STABISCOPE.
- While looking through the STABISCOPE with both eyes, move the interpapillary distance adjustment lever until you see a single, perfectly circular field of view. (Fig. 8)
- If you wear glasses, simply follow step 1 after folding the lubber eyecups back. (Fig. 9)
Focusing for Day use
-
If you have good vision and free of astigmatism, each eyepiece can be set at 0 on its diopter ring scale (Fig. 10). If you wear corrective glasses, you should also be able to set both eyepieces at 0.
In general, focusing need be done only once for viewing distant subject. In some cases, where the subject is very close, if may be necessary to re-focus. -
When focusing is required, adjust one eye-piece until the image is sharp; then adjust the other until both eyes see the image with equal clarity. (Fig. 11)
-
Manual focus as described above is also necessary when the target is at a short-distance
How to adjust focusing of night use eyepiece
-
The main switch on in the dark.
CAUTION! If the main switch was on in bright area, the image intensifier placed in the night use eyepiece might be damaged. -
Rotate a diopter ring slowly to fi nd the fi nest image of face plate. (Fig. 12)
-
Rotate a focusing ring slowly to adjust the best focus of an object. (Fig. 12)
Both of right and left eyepieces might be adjusted individually. -
Rotate the focusing rings only to adjust the focus for objects on the different distances. (Fig. 12)
How to exchange eyepiece lenses
- Place the STABISCOPE on a table or an equiva-lent fl at plane at eyepiece lenses up position. (Fig. 13)
- Rotate a mount ring counterclockwise to the full end (A). Then, pick the eyepiece lens right up slowly to take out from the eyepiece lens mount of STABISCOPE (B). (Fig. 14)
- Insert another eyepiece lens into the same mount of STABISCOPE with matching the positions of the both indicators on the mount ring and the eyepiece lens (C). (Fig. 15)
- Fit the positioning pin on the mount of STABISCOPE in engaged with the slot of the eyepiece lens, rotate the mount ring clockwise to secure the eyepiece lens firmly (D). (Fig. 16)
Hand Strap Adjust
* Adjust the length of the hand strap so that it is aligned with the grip
while you hold it.
- Unhook it. (Fig. 17)
- With your hand placed through the hand strap, pull the tip of the strap and fasten it with the Velcro so that it fits snugly around your hand. It may be necessary to repeat the process until you get the right feel. (Fig. 18)
- Hook it. (Fig. 19)
How to install the neck strap
- Remove one of the two straps passed through the clasp. Pass it through point A indicated in figure, and then pass it through the clasp again, as it was before. (Fig. 20)
- Pass the strap through point B in the figure in the same manner. (Fig. 21)
Filters and How To Use Them
The two most common types of filters used with the STABISCOPE are:
Polarizing … effective for removing unwanted and distracting reflections
from surface of water or glass. Also helpful for controlling contrast between
sky and clouds.
Orange ……… filters out bluish light (haze and mist) to improve contrast.
To install, simply place one filter over each objective lens. With polarizing filters, you can rotate each filter after placing it over the objective lens to control the exact degree of polarizing effect (contrast or removal of reflection) you want to achieve. (Fig. 22) How to use the DC Regulator Pack
-
No dry battery is required if an accessory DC regulator is used in areas where a direct current power source is available; i. e., aircraft, vehicles, etc. (Even when dry batteries are provided in this unit, if electricity is supplied through a DC regulator, the supply source of electricity will automatically be changed over to the DC Regulator.)
- The connecting method is as illustrated in the figure. (Fig. 23)
- The DC Regulator can be used within the range of 12-32 V DC.It is also possible to bend the cable as illustrated in the figure using connector cap. (Fig. 24)
CAUTION!
The cable of the external energizer has a+/- polarity. The white lead wire is
positive and the black lead wire is negative. Please take care to make the
proper connection.
Maintenance
Care and Cleaning
The STABISCOPE is built to withstand heavy duty use, but it should still be
treated with care. When not in use, it should stored in a cool, dry
environment in its own case. If it will stored for prolonged periods, the
batteries should be removed. Although the STABISCOPE is waterproof, it should
be protected from unnecessary exposure to water and humidity. In hot weather,
the STABISCOPE should not be kept in-side a closed vehicle where heat could
reach damaging levels.
Protect your eyes. Never use the STABISCOPE to look directly at the sun. It is
extremely dangerous and can cause eye damage.
Keep your STABISCOPE clean.
Lenses should be kept free of dust, salt and the oils that remain from
fingerprint smudges. These oils can actually damage the Electron Beam Coating
(EBC) applied to the lens surfaces.
To clean the lenses…
- Use a soft, lint-free cloth and a good lens cleaner or alcohol.
- Clean by rubbing the lens gently, in a circular motion, starting in the center and working your way to outer edges. If there is dust on the surface, blow it off prior to applying the cleaning cloth.
To clean the body and case…
Clean with a soft cloth, moistened if necessary. Be sure the STABISCOPE is
completely dry before placing into its case. The case can be cleaned the same
way.
Symptoms and Solutions
The most frequent problems are usually the easiest to solve.
Symptom | Cause | Solution |
---|---|---|
Targeted image is unstable | Weak batteries | Replace batteries or |
switch to external power source
Gyro motor does not rotate
LED fails to light
| Batteries are in wrong position| Check battery polarity and replace in
correct position
Weak batteries| Replace batteries or switch to external power source
Blurred image
| Out of focus| Adjust eyepieces
Stain on lens surface| Clean
Haze, mist or strong glare| Use filters
If you experience any problems with your STABISCOPE not covered above, never attempt to repair it yourself, instead, contact the dealer where you purchased the binoculars.
Specifications
Optical specification
Size
Weight
Power source
- Battery : AA (4 pcs) or lithium (type 2CR5; 1 pce)
- DC Regulator : DC12~32 volt (use with DC regulator)
Standard accessories
eyepiece (day use;
-
comes attached to binoculars) ..1 pair
-
eyepiece (night use) …………………..1 pair
-
AA battery……………………………………4 pcs
-
neck strap…………………………………….1 pce
-
hand strap ……………………………………1
-
case ……………………………………………….1
-
DC regulator ………………………………..1
-
electric cable (in) ………………………..1
electric cable (out) ……………………..1 -
cleaning cloth ……………………………..1
-
Instruction manual …………………….1
Optional accessories
- lithium battery (type 2CR5) ………1
- polarizing fi lter ……………………………1 pair
- orange fi lter …………………………………1 pair
Note
Under field of view, at 1000 m should be given; under Weight with batteries
should be given. Missing specifications include Eye Relief, Exit Pupil, and
Relative Brightness. Also, STABISCOPE housing material is not described.
For Your Safety
- Although this product is designed with safety in mind, we ask that you read and observe the following safety precautions.
- Keep this manual where it will be seen by all who use the product.
WARNINGS: Failure to observe warnings could result in death or serious
injury.
CAUTIONS: Failure to observe cautions could result in injury or property
damage.
WARNINGS:
-
Never use the binoculars to look at the sun. Doing so could cause blind-ness.
-
Should you notice anything unusual about the product, such as overheating, smoke, or a burning smell, turn it off and remove the batteries immediately. Failure to observe this precaution could result in fi re or burns. When removing the batteries, take care to avoid burns.
-
Remove the batteries immediately should water, metal, or other foreign matter fi nd their way inside the product. Failure to observe this precaution could result in fi re or in the product over-heating.
-
Do not use the product in the presence of flammable gases or liquids such as gasoline, benzine (petroleum ether), or paint thinner. Failure to observe this precaution could result in explosions, fi re, or burns.
-
Do not drop or strike the product or expose it to flame or heat. Failure to observe this precaution could cause the casing to rupture.
-
Do not place the product on unstable surfaces. Injury could result if the product tips or falls.
-
Do not use the product while walking. Failure to observe this precaution could result in collisions, falls, or injury.
-
Operators could pinch their fingers when adjusting eye width. Observe caution when allowing small children to use the product.
-
Do not leave the product in direct sunlight. Failure to observe this precaution could result in fi re.
-
Deterioration of the rubber eyecups as the result of prolonged use could cause inflammation of the skin. Consult a physician should experience symptoms that could be the result of inflammation.
-
Consult a physician immediately should a child swallow a cap.
-
Plastic bags and wrapping are a suffocation hazard. Keep them out of reach of children.
-
Under no circumstances should you attempt to disassemble the product. Failure to observe this precaution could result in injury. Disassembling the product also voids the warranty.
WARNINGS (Batteries)
- To prevent serious accidents caused by the batteries overheating or leaking, never:
- Use batteries if the casing is damaged or peeling
- Use batteries if the nominal voltage cannot be determined or exceeds 1.5 V (AA batteries only)
- Mix batteries of different types and makes
- Mix fresh and used batteries
- AA lithium, manganese, and NiCad batteries are not supported, and to ensure customer safety should not be used.
- Do not use the product if the batteries are not inserted with the “+” and “−” contacts in the correct orientation.
- Do not short or disassemble batteries or expose them to heat or flame. Failure to observe this precaution could result in the batteries rupturing or cause fi re or injury.
- Refer to the documentation provided by the manufacturer for information on the use and storage of, and operating conditions for, AA alkaline, NiMH, and lithium (type 2CR5) batteries.
CAUTIONS
- In the event of product malfunction, do not attempt to repair the product yourself. Consult the original retailer.
- Should the product break open as the result of a fall or other accident, do not touch the exposed parts. Failure to observe this precaution could result in injury.
- Do not touch the interior of the battery chamber with metal objects. Failure to observe this pre-caution could result in injury or product malfunction.
- Remove the batteries if the product will not be used for an extended period. After removing the batteries, reinsert the battery cover to protect the product during storage.
- Keep the product out of reach of children. Failure to observe this precaution could result in injury.
- Do not place the product under blankets, cloths, cushions, or the like. The buildup of heat could deform the casing or cause fi re.
- Should liquid from the batteries come into contact with skin or clothing, flush the affected area with water. Should battery liquid enter the eyes or mouth, flush the affected area with water and consult a physician immediately.
Disposal of Electrical and Electronic Equipment in Private Households
In the European Union, Norway, Iceland and Liechtenstein: This symbol on the product, or in the manual and in the warranty, and/or on its packaging indicates that this product shall not be treated as household waste. Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent
potential negative consequences to the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product.
This symbol on the batteries or accumulators indicates that those batteries
shall not be treated as household waste.
If your equipment contains easy removable batteries or accumulators please
dispose these separately according to your local requirements.
The recycling of materials will help to conserve natural resources. For more
detailed information about recycling this product, please contact your local
city o ffi ce, your household waste disposal service or the shop where you
purchased the product.
In Countries Outside the European Union, Norway, Iceland and Liechtenstein: If
you wish to dis-card this product, including the batteries or accumulators,
please contact your local authorities and ask for the correct way of disposal.
U.K. Importer:
FUJIFILM UK Limited
Fujifi lm House, Whitbread Way, Bedford, Bedfordshire, MK42 0ZE, United Kingdom
EU Importer:
FUJIFILM Electronic Imaging Europe GmbH
Fujistrasse 1 47533 Kleve, Germany
Read User Manual Online (PDF format)