THORGEON 03073 LED High Bay Light Instructions
- June 12, 2024
- THORGEon
Table of Contents
THORGEON 03073 LED High Bay Light
PRODUCT FEATURES
- This product made of aluminum is designed with excellent heat dissipation based on chimney structure.
- With a working temperature between -30°C to 50°C, this product can be applied to different circumstances.
- Easy ring-type installation and maintenance.
- 5-year guarantee. Kindly remind: Please keep this instruction manual for future use.
Product Application
- Warehouse, library, workshop, shopping mall, supermarket, theme restaurant, gymnasium, cinema, hospital, apparel shop,bar etc.
PRODUCT FEATURES
This product made of aluminum is designed with excellent heat dissipation
based on the chimney structure. With a working temperature between -30°C to
50°C, this product can be applied to different circumstances.
Easy ring type installation and maintenance.
Kindly remind: please keep this instruction manual for future use.
PRODUCT APPLICATION
Warehouse, library, workshop, shopping mall, supermarket, theme restaurant, gymnasium, cinema, hospital, apparel shop, bar et
SPECIFICATION
model no. | 03071 | 03072 | 03073 |
---|---|---|---|
power | 100W | 150W | 200W |
power factor | >0.95 | >0.95 | >0.95 |
net weight | 2.25kg | 2.86kg | 3.82kg |
Product Size | 17×29 | 17×34 | 18.2×38 |
IP grade | IP 65 |
- voltage: AC120-277V 50/60Hz
- working temperature: -30°C-+50°C
- working humidity: 15%-90%RH
- warranty: 5 years
REMOTE CONTROL PROCEDURE
- Microwave motion sensor settings- One sensor
- Press “ON/OFF” to turn on the light.
- Press” Scene”to reset the remote and switch to sensor mode.
- Press related keys to set Detection Area, Hold Time, daylight threshold, stand-by period and stand-by dimming level with pressing “+”/”-” within 5s when the icon start to fl ash.
- Then all settings would be kept automatically until the next reset.
- Start / Memory / Apply-Applied to more sensor
- Press “ON/OFF” to turn on the light
- Press “Scene” to enter sensor mode. Then press “Start” to start the user-defined setting.
- Press related keys to set Detection Area, Hold Time, daylight threshold, stand-by period and stand-by
- dimming level with pressing “+”/”-” within 5s when the icon start to fl ash.
- Press “Memory” to store the setting.
- Press” Apply” to all sensors within remote IR range, the light will blink rapidly when receiving the signal, which means the sensor has been set successfully.
POWER OUTPUT SETTING
- The output could be set under two mode-Sensor Mode and Always ON Mode.
- Under always ON mode, press”+”/”-” to adjust the output from 10%-100%.
- Under the sensor mode, press “Scene”-” Power”, then press”+”/”-” to adjust the output from 60%-100%.
Note: Under the sensor mode, the data shown in the display could be set from 10%-100%, but the brightness would be 60% at lowest and won’t dim any
SPECIFICATION
Input | Voltage | 10.5-1 5V DC (Currect Required>30mA) |
---|---|---|
Output | Standby Consumption | <30mA (Power Consumption) |
Dim Output | DIM 1-10V | |
Daylight Priority Function | Detection area: 120Lux/80Lux/50Lux/30Lux Stand-by |
period: +∞
Stand-by dimming level: 10%/20%/30%
Sensor Parameters| Detection Area| 25%/50%/75%/100%
Holdtime| 5s/30s/1min/3min/5min/1Omin/20min/30min
Daylight Threshold| 2Lux/10Lux/30Lux/50Lux/80Lux/120Lux/200Lux/250Lux/
300Lux/350Lux/400Lux/Disable
Stand-by Period| Os/10s/30s/1min/5min/1Omin/30min/+∞
Stand-by Dimming Level| 10%/20%/30%/50%
Microwave Frequency| 5.8GHz±75MHz
Mounting Height| ≤12m/39.36ft (Ceiling Mounted)
Detection Range| Max,016m/52.49ft (Ceiling Mounted)
Others| Temperature| -20°C-+60°C
| IP Grade| IP65
| Warranty (Years)| 5
Remark| Factory Default Setting: Detection area 100%/ Hold time 5s/ Daylight
threshold Disable/ Stand-by period Os/Stand-by dimming level 10%.
DAYLIGHT PRIORITY
- Dusk/Dawn sensor:
- Dual-PD technology brings a fully automatic dusk/dawn sensor which can tell the difference between natural light and LED light, to ensure the light will be off when needed.
CAUTIONS
- Cut off before lamp installation and maintenance.
- Clean the lamp surface with a soft brush from top to bottom.
- Wipe the lamp surface with industrial alcohol on the dry cloth instead of water or corrosive liquid.
- In case of fire, explosion, electric shock etc, installation, inspection and maintenance must be handled by professional electricians.
- Totally cut off the power before installing the lamp, make sure it is effectively grounded.
- The lamp can only normally work under allowable voltage.
- Lamp life is subject to the environmental temperature, please ensure lamp work under regulated temperature.
- Lamps not to be used in a closed and narrow space.
- The hook or chain to be used for installation must support at least 3 times lamp weight. Lamp can not be installed near to the tuyere,shaking and unstable environment.
WARRANTY
- This lamp is guaranteed for 5 years only by proper use, excluding problems caused by fi re, earth quake etc.
- Please read this instruction manual carefully and follow relevant rights.
- The product is subject to change without notice.
Scan me
Contact
www.thorgeon.com
SIA “ATTA-1”, Jurkalnes street 1, Riga, Latvia, LV-1046
Read User Manual Online (PDF format)