THORGEON 03073 LED High Bay Light Instructions

June 12, 2024
THORGEon

THORGEON-logo

THORGEON 03073 LED High Bay Light

THORGEON-03073-LED-High-Bay-Light-product

PRODUCT FEATURES

  • This product made of aluminum is designed with excellent heat dissipation based on chimney structure.
  • With a working temperature between -30°C to 50°C, this product can be applied to different circumstances.
  • Easy ring-type installation and maintenance.
  • 5-year guarantee. Kindly remind: Please keep this instruction manual for future use.

Product Application

  • Warehouse, library, workshop, shopping mall, supermarket, theme restaurant, gymnasium, cinema, hospital, apparel shop,bar etc.

PRODUCT FEATURES

This product made of aluminum is designed with excellent heat dissipation based on the chimney structure. With a working temperature between -30°C to 50°C, this product can be applied to different circumstances.
Easy ring type installation and maintenance.
Kindly remind: please keep this instruction manual for future use.

PRODUCT APPLICATION

Warehouse, library, workshop, shopping mall, supermarket, theme restaurant, gymnasium, cinema, hospital, apparel shop, bar et

SPECIFICATION

model no. 03071 03072 03073
power 100W 150W 200W
power factor >0.95 >0.95 >0.95
net weight 2.25kg 2.86kg 3.82kg
Product Size 17×29 17×34 18.2×38
IP grade IP 65  
  • voltage: AC120-277V 50/60Hz
  • working temperature: -30°C-+50°C
  • working humidity: 15%-90%RH
  • warranty: 5 years

REMOTE CONTROL PROCEDURE

  1. Microwave motion sensor settings- One sensor
    • Press “ON/OFF” to turn on the light.
    • Press” Scene”to reset the remote and switch to sensor mode.
    • Press related keys to set Detection Area, Hold Time, daylight threshold, stand-by period and stand-by dimming level with pressing “+”/”-” within 5s when the icon start to fl ash.
    • Then all settings would be kept automatically until the next reset.
  2. Start / Memory / Apply-Applied to more sensor
    • Press “ON/OFF” to turn on the light
    • Press “Scene” to enter sensor mode. Then press “Start” to start the user-defined setting.
    • Press related keys to set Detection Area, Hold Time, daylight threshold, stand-by period and stand-by
    • dimming level with pressing “+”/”-” within 5s when the icon start to fl ash.
    • Press “Memory” to store the setting.
    • Press” Apply” to all sensors within remote IR range, the light will blink rapidly when receiving the signal, which means the sensor has been set successfully.

POWER OUTPUT SETTING

  • The output could be set under two mode-Sensor Mode and Always ON Mode.
  • Under always ON mode, press”+”/”-” to adjust the output from 10%-100%.
  • Under the sensor mode, press “Scene”-” Power”, then press”+”/”-” to adjust the output from 60%-100%.

Note: Under the sensor mode, the data shown in the display could be set from 10%-100%, but the brightness would be 60% at lowest and won’t dim any

SPECIFICATION

Input Voltage 10.5-1 5V DC (Currect Required>30mA)
Output Standby Consumption <30mA (Power Consumption)
Dim Output DIM 1-10V
Daylight Priority Function Detection area: 120Lux/80Lux/50Lux/30Lux Stand-by

period: +∞

Stand-by dimming level: 10%/20%/30%

Sensor Parameters| Detection Area| 25%/50%/75%/100%
Holdtime| 5s/30s/1min/3min/5min/1Omin/20min/30min
Daylight Threshold| 2Lux/10Lux/30Lux/50Lux/80Lux/120Lux/200Lux/250Lux/ 300Lux/350Lux/400Lux/Disable
Stand-by Period| Os/10s/30s/1min/5min/1Omin/30min/+∞
Stand-by Dimming Level| 10%/20%/30%/50%
Microwave Frequency| 5.8GHz±75MHz
Mounting Height| ≤12m/39.36ft (Ceiling Mounted)
Detection Range| Max,016m/52.49ft (Ceiling Mounted)
Others| Temperature| -20°C-+60°C
 | IP Grade| IP65
 | Warranty (Years)| 5
Remark| Factory Default Setting: Detection area 100%/ Hold time 5s/ Daylight threshold Disable/ Stand-by period Os/Stand-by dimming level 10%.

DAYLIGHT PRIORITY

  • Dusk/Dawn sensor:
  • Dual-PD technology brings a fully automatic dusk/dawn sensor which can tell the difference between natural light and LED light, to ensure the light will be off when needed.

CAUTIONS

  1. Cut off before lamp installation and maintenance.
  2. Clean the lamp surface with a soft brush from top to bottom.
  3. Wipe the lamp surface with industrial alcohol on the dry cloth instead of water or corrosive liquid.
  4. In case of fire, explosion, electric shock etc, installation, inspection and maintenance must be handled by professional electricians.
  5. Totally cut off the power before installing the lamp, make sure it is effectively grounded.
  6. The lamp can only normally work under allowable voltage.
  7. Lamp life is subject to the environmental temperature, please ensure lamp work under regulated temperature.
  8. Lamps not to be used in a closed and narrow space.
  9. The hook or chain to be used for installation must support at least 3 times lamp weight. Lamp can not be installed near to the tuyere,shaking and unstable environment.

WARRANTY

  1. This lamp is guaranteed for 5 years only by proper use, excluding problems caused by fi re, earth quake etc.
  2. Please read this instruction manual carefully and follow relevant rights.
  3. The product is subject to change without notice.

Scan me

www.thorgeon.com/03073

Contact

www.thorgeon.com
SIA “ATTA-1”, Jurkalnes street 1, Riga, Latvia, LV-1046

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>