milwaukee 2267-40 Infrared Temp Gun Instruction Manual

October 30, 2023
Milwaukee

milwaukee-LOGO

2267-40 Infrared Temp Gun

milwaukee-2267-40-Infrared-Temp-Gun-PRODUCT

Product Information

This product is a machine with buttons and a laser thermometer for measuring temperature. It comes with a battery pack that can be removed before starting any work on the machine. The machine has a distance laser point to center of spot temperature area of 150mm which is equivalent to 1.5m. The temperature area is represented by b and the distance laser thermometer to measure point is represented by c. The rate between distance Laser Thermometer and measure point is approximately 10:1.

Product Usage Instructions

  1. Before starting any work on the machine, remove the battery pack.
  2. Check the plug and power cord for any damage. Any repairs should be done by a professional.
  3. When working on the machine, make sure to remove the interchangeable battery.
  4. Use the ON/OFF button to turn the machine on and off.
  5. The machine comes with a laser thermometer for measuring temperature. Use button ‘a’ to activate the laser.
  6. The machine has a distance laser point to center of spot temperature area of 150mm which is equivalent to 1.5m. Use button ‘b’ to adjust the temperature area.
  7. The rate between distance Laser Thermometer and measure point is approximately 10:1. Use button ‘c’ to adjust the distance laser thermometer to measure point.

Technical Data

No technical data is provided in the user manual.

milwaukee-2267-40-Infrared-Temp-Gun-PRODUCT

Description of Buttons

milwaukee-2267-40-Infrared-Temp-Gun-1

Basic Settings

Remove the battery pack before starting any work on the machine.

milwaukee-2267-40-Infrared-Temp-Gun-2

  • Distance laser point to center of spot temperature area (19 mm)
  • Temperature area
  • Distance Laser Thermometer to measure point

The rate between distance Laser Thermometer and measure point is approx. 10:1.

milwaukee-2267-40-Infrared-Temp-Gun-3

milwaukee-2267-40-Infrared-Temp-Gun-5

SAFETY INSTRUCTIONS

CAUTION! WARNING! DANGER!
Do not use the product before you have studied the safety instructions and the user manual.

Laser Classification

WARNING :
It is a Class 2 laser product in accordance with EN60825-1:2014 .

CONSUMER LASER PRODUCT: EN 50689:2021

  • Do not stare into beam. Do not point laser light at other persons.
  • Do not view directly into beam with optical instruments (binocular, telescope).
  • Do not point laser at refl ective surfaces.
  • Avoid exposure to laser radiation. Laser may emit hazardous radiation.
  • Avoid dangerous environments. Do not use in rain, snow, damp or wet locations. Do not use in the presence of explosive atmospheres (gaseous fumes, dust or fammable materials) because sparks may be generated when inserting or removing battery pack, possibly causing fi re.
  • This tool is designed to be powered by 9 V battery properly inserted into the Instrument. Do not attempt to use with any other voltage or power supply.
  • Do not leave batteries within the reach of children.
  • Do not mix new and used batteries. Do not mix brands (or types within brands) of batteries.
  • Do not mix rechargeable and non-recharge-able batteries. Install batteries according to polarity (+ / –) diagrams. Properly dispose of used batteries immediately.
  • Battery acid may leak from damaged batteries under extreme load or extreme temperatures. In case of contact with battery acid wash it off immediately with soap and water. In case of eye contact rinse thoroughly for at least 10 minutes and immediately seek medical attention.

This appliance is not intended to  be used or cleaned by persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given instructions concerning the safe use of the appliance by a person legally responsible for their safety. They should be supervised whilst using the appliance. Children shall not use, clean or play with this appliance, which when not in use should be secured out of their reach.
Warning! To reduce the risk of fi re, personal injury, and product damage due to a short circuit, never immerse your tool, battery pack or charger in fl uid or allow a fl uid to fl ow inside them. Corrosive or conductive fl uids, such as seawater, certain industrial chemicals, and bleach or bleach containing products, etc., can cause a short circuit.

SPECIFIED CONDITIONS OF USE
The Laser Thermometer can be used for non-contact temperature measurement.
Do not use this product in any other way as stated for normal use.

DISPLAY

SELECTING CELSIUS OR FAHRENHEIT
To set the temperature scale, pull the trigger and then press the SET button three times. Press the buttons above the up and down arrows to toggle between °C and °F. Wait 5 seconds for the setting to save and exit.

SETTING THE LASER LOCK
To turn the laser on and off , pull the trigger and then press the SET button four times. Press the buttons above the up and down arrows to toggle between ON and OFF. Wait 5 seconds for the setting to save and exit.

OPERATION

Scanning Object IR Temperature

  1. Pull and hold the trigger for at least 2 seconds and scan the surface temperature of an object. A laser pointer indicates the center of the circular area being scanned.
    NOTE : The object should be larger than the spot being scanned. If not, readings willbe aff ected. See Distance To Spot for necessary object size.

  2.  As you continue to hold the trigger, the icon is displayed along with the surface temperature (primary measurement) and maximum temperature (secondary measurement) readings.

  3. Release the trigger. HOLD is displayed until the screen shuts off in about seven seconds.

NOTE : A quick change in temperature (>10°C) aff ects the meter’s readings. Allow the meter to reach ambient temperature before use (5 to 30 minutes, depending on temperature change).

Temperature Alarm
Press the ALARM button to turn on the alarm function. The bell icon is displayed. If the temperature reading is outside the preset range, the temperature reading will fl ash.

Setting Preset Range for the Alarm

  1. To set the alarm range, pull the trigger and then press the SET button. Repeat to toggle between HI and LO settings.
  2. Press the up or down arrow soft keys to toggle between temperatures. Wait 5 seconds for the ranges to save and exit.

Low Battery
When the Low Battery icon is displayed, change the batteries.

milwaukee-2267-40-Infrared-Temp-Gun-8

MODE INDICATOR

MAX : Displays maximum temperature measured during a continuous reading
MIN : Displays minimum temperature measured during a continuous reading
AVG : Displays average temperature of last 20 measurements during a continuous reading4
DIF : Displays the diff erence between MAX and MIN during a continuous reading

MAINTENANCE

Clean the laser windows with a soft, moist cloth to keep them clean and clear. Remove battery before cleaning.
Warning!

  •  To reduce the risk of personal injury and damage, never immerse your tool in liquid or allow a liquid to fow inside it.
  • Clean dust and debris from tool. Keep tool handles clean, dry and free of oil or grease. Use only mild soap and a damp cloth to clean the tool since certain cleaning agents and solvents are harmful to plastics and other insulated parts. Never use fl ammable or combustible solvents around tools
  • Use only Milwaukee accessories and Milwaukee spare parts. Should components need to be replaced which have not been described, please contact one of our Milwaukee service agents (see our list of guarantee/service addresses).
  • If needed, an exploded view of the tool can be ordered. Please state the Article No. as well as the machine type printed on the label and order the drawing at your local service agents or directly at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.

SYMBOLS

milwaukee-2267-40-Infrared-Temp-Gun-9

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals