POWER SOLID PS-PGU1500VA2B9A Line Interactive Gaming UPS User Manual
- June 10, 2024
- POWER SOLID
Table of Contents
1500VA
GAMING UPS
PS-PGUT500VA#2B9IA
USER MANUAL
WWW.POWERSOLID.VN
INSTALLATION & OPERATION
① Package Contents
Before installation, please read and understand the following items are inside
the box:
- UPS unit
- User manual
- Communication cable
- Software for UPS
② Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to charge
inside battery. For best result, charge the battery for 24 hours prior to
initial use.
③ Plug in Equipment
Plug your equipment to Battery Backup Outlets on the rear panel of the UPS.
NOTE: Make sure that the UPS is powered on to protect all important
devices from data loss during power failure.
CAUTION: NEVER connect a laser printer or scanner to the battery backup
outlets of UPS.
This way cause the damage of the unit.
④ Connect Communication Cable
To allow for unattended UPS shutdown/start-up and status monitoring, connect
the communication cable one end to the USB port and the other to the
communication port of your PC. With the monitoring software installed, you can
schedule UPS shutdown/start-up and monitor UPS status through PC.
⑤ Turn On/Off the UPS
Turn on the UPS unit by pressing the power switch. Then, the LCD will display
UPS status.
Turn off the UPS unit by pressing again the power switch. Then, LCD display
will shut off.
⑥ Turn On/Off the LCD screen
When the UPS in AC mode. Press on the power switch once, the LCD screen will
shut off.
Press on the power switch once again, the LCD screen will be on.
⑦ Mute function
In battery mode, press on the power switch once, the buzzer will be off. But
when the UPS is low battery or overloaded, the buzzer will be on to remind the
UPS will be shut down immediately.
⑧ RGB Lights.
All RGB lights will be lighting when the UPS in AC mode. The RGB light on
above will be lighting when the UPS in battery mode. Press on the power switch
twice, the RGB lights will be off. Press on the power switch twice again, the
RGB lights will be on.
PLACEMENT & STORAGE
① Placement
Install the UPS in a protected area that is free of excessive dust and has
adequate air flow.
Place the UPS away from other units at least 20 cm to avoid interference. For
best performance, keep the indoor temperature between 0° C and 40° C.
② Storage
All connected equipment should be turned off, then disconnect from the UPS to
avoid battery drain. Unplug the UPS from the wall outlet. Then turn off the
UPS for storage. Store the UPS unit covered and upright in environments where
the ambient temperature is -20° C to 50° C with its battery fully charged.
PRODUCT OVERVIEW
FRONT PANEL
1)LCD display
2)RGB lights| 3)Power switch
4)5V USB port
---|---
REAR PANEL
1)Output socket
2)USB port| 3)Circuit breaker
4)AC input
---|---
LCD DISPLAY
Operation Display
UPS Mode | LCD | Description |
---|---|---|
UPS Power on | UPS is powered on. | |
AC Mode | LCD information will be displayed in the following order when LCD |
is touched.
1)Output voltage
2)Input voltage
3)Load level
4)Battery capacity
Overload in AC mode| | When overload occurs, alarm will beep every 0.5 second.
Battery Mode| | Alarm will beep every 10 seconds and LCD information will be
displayed in the following order when LCD is touched.
1)Output voltage
2)Input voltage
3)Load level
4)Battery capacity
Overload in Battery mode| | When overload occurs, alarm will beep every 0.5
second.
SAFETY CAUTION
SAVE THESE INSTRUCTION-This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
-
This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. Only factory service personnel may perform repairs.
-
This pluggable type a equipment with battery already installed by the supplier is operator installable and may be operated by laymen.
-
The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.
-
During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA.
-
Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes.
-
In the event of an emergency, press the “OFF” button and disconnect the power cord from the AC power supply to properly disable the UPS.
-
Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
-
This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.
-
Do not plug the UPS input into its own output.
-
Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
-
Do not dispose of batteries in a fire as they may explode.
-
A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
①Remove watches, rings, or other metal objects from the hands.
②Use tools with insulated handles.
③Wear rubber gloves and boots.
④Do not lay tools or metal parts on top of batteries.
⑤Disconnect charging source prior to connecting or disconnecting batteries terminal. -
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
-
When replacing batteries, replace with the same number and type of sealed lead-acid battery.
-
Do not open or mutilate the battery or batteries. Release electrolyte is harmful to the skin and eyes. It may be toxic.
-
Attention, hazardous through electric shock. Also with dis- connection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary.
-
To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces.
-
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Specification
Model | PS-PGU1500VA#2B9A |
---|---|
Capacity(VA) | 1500VA/900W |
Input Voltage range(V) | 145Vac-290Vac |
Input Frequency(Hz) | 50Hz±1% OR 60Hz±1% |
Output Voltage range(V) | 220V±10% |
Transfer time | Typical 4-6ms |
Waveform | Simulated Sine Wave |
Battery Type | 12V9AH*2 |
Typical recharge time | 8 hours recover to 90% capacity |
Dimension(mm) | 330115265 |
Weight(Kg) | 20kg |
Humidity | 0-90%RH @ 0-40℃(non-condensing) |
Noise Level | Less than 50dB |
USB Communication Port | YES |
5V USB | 2pcs |
RGB light | 2pcs |
TROUBLESHOOTING
Problem | Possible Cause | Solutions |
---|
Nothing is
displayed on LCD
panel.| The UPS is not on.| Press the power switch again to turn on the UPS.
Battery voltage is too low.| Charge the battery at least 6 hours.
Battery fault.| Replace the battery.
The UPS always
on battery mode.| Power cord loose.| Re-plug the power cord.
Backup time too
short.| Battery voltage is too low.| Charge the battery at least 6 hours.
Overload.| Remove some unnecessary loads. Before reconnecting equipment,
please verify that the load matches the UPS capability specified in the specs.
Battery defect.| Replace the battery.
If any abnormal situations occur that are not listed above, please call for service immediately.