POWER SOLID PSi400VA#12VPVT Inverter 400VA User Manual

June 10, 2024
POWER SOLID

POWER SOLID PSi400VA#12VPVT Inverter 400VA

Product Information

The product is a PSi400VA#12VPVT inverter that can convert DC power from a battery or solar panel into AC power for household or commercial use. It has an input capacity of 400VA/250W and a nominal DC voltage of 12V. The inverter can automatically sense the input voltage range and frequency of 154-265VAC and 50-60Hz. The output power is 250W with a pure sinewave frequency of 50/60Hz and a transfer time of 50%. The inverter has LED indicators that show the power source and charging status. It also has function keys for setting and configuration.

Product Usage Instructions

  • Function Setting
    To enter setting mode, press the ENTER button for 10 seconds. To exit setting mode, press the ESC button repeatedly. Use the UP or DOWN button to choose the parameter and then press ENTER to select it. When the parameter is flashing, use UP or DOWN to change it and then press ENTER to confirm. The setting icon will flash when setting, the left-sided frame of the parameter will flash when the setting succeeds, and the ERROR light will turn on when the setting fails.

  • Care and Maintenance
    Refer to the user manual for instructions on the care and maintenance of the product.

  • Rapid Troubleshooting and Maintenance
    Refer to the user manual for instructions on rapid troubleshooting and maintenance of the product.

  • Technical Datasheet
     The technical datasheet provides information on the product specifications, including input and output capacity, voltage range and frequency, waveform, transfer time, low voltage shutdown and recovery, high voltage alarm and recovery, and optional PV array power. The datasheet also provides information on the product’s environmental conditions, including temperature, humidity, and acoustic noise.

  • Appendix
    The appendix provides information on how to choose and configure PV panels for use with the inverter. It lists the parameters that can be found in the specifications of each PV panel, including maximum output power, open circuit voltage, short circuit current, rated voltage, and rated current. It also provides instructions on how to connect PV panels in series or parallel to obtain the required output voltage and current.

Operating Instruction

0pen-package inspection

  1. After opening the package, please check the attached parts and components, including the operation manual and checking whether the the inverter is in good condition? If found any inverter is broken or components missing, do not turn on the machine, feedback to the carrier or supplier.
  2. Note: Please keep the box and packing materials in case the use in the future.

Installation notice:

  1. The products should be well-ventilated, away from water and corrosive and combustible gases.
  2. Do not set it in a corner, ensure the bottom of the front panel, the rear panel fan outlet and the side of the machine are well-ventilated.
  3. The environment temperature should remain 0-10°C.
  4. If the machine operates under a low-temperature environment, it would cause water condense, only in an absolutely dry condition can the machine would work normally, otherwise, there will be an electric shock.
  5. Install the inverter near the mains input socket or nearby the switch, to draw out plugs then cut off the mains supply once there is an emergency.

Attention:

  1. The load should be turned off before connecting to the inverter and turned on one by one after connecting is completed.
  2. The inverter should be connected to a socket with a corresponding current protection.
  3. All power sockets should link with ground protection.
  4. No matter input power cable inserts to the main socket or not, the inverter will also continue outputting possibly, turning off the inverter can not guarantee there is no current inside the machine. In order to make sure to cut off the output of the inverter, you should turn off all the switches and then turn off the main supply.
  5. To load inductive appliances such as electromotor, displayed, and laser printer, the inverter capacity should be twice as loading machine’s rated power at least.

Description Of Front Board

  1. 1. Power ON/OFF switch
  2. LCD display
  3. ED indicators
  4. Function keys
  5. Input seat
  6. Output seat
  7. Solar panels connect terminals
  8. Battery connect terminals
  9. Wire holes
  10. Input seat fuse
  11. Saver Mode
  12. Off Mode
  13. On Mode

LED INDICATOR

Function Kevs

Function Key Description
ESC To exit setting mode
UP To go to previous selection
DOWN To go to next selection
ENTER To confirm the selection in setting mode or enter setting mode

Function setting

Enter setting mode, Press “ENTER” button for 10 seconds.
Exit setting mode, Press “ESC” button repeatedly.

  1. Press up or down button to choose the parameter and then press “ENTER” button.
  2. When parameter is flashing, press up or down to change it and then press “ENTER” button to confirm.
    • When setting: Setting icon is flashing
    • Setting succeed: Left-sided frame of the parameter will flash Setting
    • failed: ERROR light on

Settings| Display

(Left)

| Display (Mid)| Display (Right)| Setting range
---|---|---|---|---
Boost charging voltage| cu| 06| 14.2V| 13.5~15.0V
Float charging voltage| FLU| 07| 13.6V| 12.5~14.0V
Battery lockdown voltage| cou| 08| 10. 2V| 9. 5v~n. 5V
Charging voltage of mains recovery| OTA| 09| 12.ov| 11. 5~12. 5V
Charging voltage of mains off| ATD| 10| 13. 5V| 13.ov~14.ov
Inv. output voltage| OU| 11| 220V| 200~24ov

Mains detection speed

|

CST

|

12

| HI| High speed
IDE| Mid. speed
LO| Low speed
Inv. output frequency| OF| 13| 50Hz|
60Hz|
Fault restart switch| RA| 14| TE| On
TD| Off

Backlight control

|

BLC

|

15

| LON| Always on
LOF| Always off
LOD| Delay off
Buzzer control switch| BEC| 16| AON| On
AOF| Off
Low battery alarm switch| BOL| 17| OFF| Off
ON| On
Load limit| LL| 18| OFF| Off
ON| On
Load alarm limit| LEL| 19| OFF| Off
ON| On

Baud rate

|

BAU

|

20

| 0| 2400
1| 4800
2| 9600
Factory| RS| | OFF| Off
ON| On

Error codes for reference

Display (Left) Display (Right) Details
ALA 021 Inverter communication connection failure alarm
ALA 233 Abnormal mains output alarm
ALA 236 Abnormal machine load alarm
ALA 237 Inverter overload alarm
ALA 231 Abnormal output alarm
ALA 234 High battery voltage alarm
ALA 235 Low battery voltage alarm
ALA 241 Memory chip read and write error alarm
ALA 232 Memory chip connection failure alarm
ALA 238 Inverter over temperature alarm
ALA 239 Load-causing over temperature alarm
ALA 242 Host computer software planned shutdown alarm
FAL 102 Inverter overload shutdown fault
FAL 104 Abnormal output fault
FAL 105 Abnormal load fault
FAL 106 Inverter over temperature fault
FAL 135 High battery voltage fault
FAL 134 Low battery voltage fault
FAL 123 Load-causing over-temperature fault
FAL 169 Current detection signal failure
FAL 161 Abnormal mains output fault
FAL 152 Temperature sensor connection failure
FAL 162 Host computer software planned shutdown failure

Care and maintenance

  1. This inverter is low in repair rate. The battery of the standard model is valve adjusting, low maintenance, ensuring better life onlyby charging often. When connecting to mains supply, no matter inverter on or off, it still keeps charging for battery, and provide overcharge, over-discharge protection.
  2. If there has been long time no using, please discharge then charge the inverter each 4-6 months.
  3. Usually, the life span of the battery is 3-5 years. If any wrong with it, please ask professionals for changing. And do not change it by yourself.
  4. Don’t change the single battery, changing the battery should according to the suppliers instructions.
  5. Normally, the battery should discharge then recharge every four or six months, charging for it more than 12 hours after discharging.
  6. At high-temperature area, the battery should be discharged and charging every 2 months and the standard charging time is 12 hours at least each time.

Note:

  1. Before changing battery, must turn off inverter and disconnect the mains supply.
  2. Remove metal object like ring, watch etc.
  3. Please don’t put the metal objects on the battery.
  4. This is the normal phenomenon, when connecting the battery wire, the wiring will appear at a small spark.
  5. Be attentive to connecting between anode and cathode.

Rapid troubleshooting and maintenance

Fault Cause Solution
No city power input Recoverable fuse broken Change the fuse
Terminal heating Fault or lose connection Fasten again
No Output Battery no energy or overload Charge the battery or reduce the

loads


Switch on failure

| Fault connection with city power or battery| Check connection with battery or connect again
Alarm when switching on| Battery no energy or overload| Charge the battery or reduce the loads
Buzzer screams every second| Over temperature alarm or low battery alarm| Check if the fan heat dissipation hole jammed
Fan sometimes twirls or sometimes stop| Fan twirls when inside temperature reaches 45’C, stop when 37’C| The normal phenomenon, the fan is under intelligent control

Technical Datasheet

MODEL PSi400VA#12VPVT
Input
Capacity(VA) 400VA/250W
Voltage(DC) 12V
Nominal Voltage 220VAC
Voltage Range 154-265VAC
Frequency 50-60Hz Auto-sensing
Output
Watt 250W
Voltage 220VAC
Frequency 50/60Hz
Waveform Pure sinewave
Transfer time(ACto DC) <8ms
Transfer time( DC to AC) <8ms
Output voltage regulation 10% rms
Bypass Mode Yes
Saver Mode Yes
Efficiency >98%
Battery
Battery Type AGM-Deep Cycle, GEL

Up to 500Ah
Charging current| 9A
Low Level disconnect

(Selectable)

| 10V or 10. 5V



LCD Indicator status

| Input AC, Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency


LED Indicator status

| AC Line In: Green
Inverter: Green
Charging: Yellow
Alarm: Red
Battery low alarm| battery light discharge 11. 5VN: battery load discharge 11.5VN@load<20% ; 11VN@load>50%/10.5VN@load>50%;
Battery low recovery| battery light discharge 12VN; battery load discharge 12VN@load<20%;

11.5VN@load>50%/11VN@load>50%;

DC low voltage shutdown| battery light discharge 11VN: battery load discharge 11VN@load<20%

10.5VN@load>50%/10VN@load>50%

DC high voltage alarm

and fault

| 16VN
DC high voltage recovery| 15V
N
Optional|
Maximum PV array power| 800W
MPPT input voltage range| 15-150VDC
Maximum PV array open

circuit voltage

| 150VDC
Maximum solar charging

current

| 60A
Alarm|
Low battery alarm| The buzzer beeps once a second and stops after one minute
Overload alarm| The buzzer keeps beeping and stops after one minute
Fault| The buzzer keeps beeping and stops after one minute
Environment|
Temperature| 0-40
Humidity| C0-95% , Non condensing
Accoustic Noise(db)| >55dB

Appendix

How to choose and configure PV panels
The following parameters can be found in the specifications of each PV panel:

  • Pmax: Maximum output power (W)
  • Voc: Open circuit voltage (V)
  • Isc: Short circuit current (A)
  • Vpm: Rated voltage (V)
  • Ipm: Rated current (A)

PV panels can be connected in series or in parallel to obtain the required output voltage and current to meet the allowable range of the solar controller. When connecting PV panels in series, the total maximum voltage and current is:

When the PV panels that have been connected in series are connected in parallel, the total maximum voltage and current are:![POWER-SOLID-PSi400VA

12VPVT-Inverter-400VA-fig-6](https://manuals.plus/wp-content/uploads/2023/05

/POWER-SOLID-PSi400VA12VPVT-Inverter-400VA-fig-6.jpg)

  • In either case, the total output power is the power of a single PV panel X the total number of PV panels. The criteria for configuring PV panels is that the total power should be equal to or slightly greater than the maximum allowable PV power of the solar controller (please refer to the technical parameter table ). The excess capacity of PV panels does not contribute to the capacity of solar chargers and will only lead to higher installation costs.

  • The total Ipm of the PV panels should be less than the maximum charging current of the inverter (60A)

  • The total Voc of the PV panel should be less than the maximum PV input voltage of the inverter (please refer to the technical parameter table).
    Example 1: Take a 12-inverter as an example to select suitable PV modules.

  • Considering that the total Voc of the PV panel cannot exceed the maximum 150VDC. The total power should be equal to or slightly greater than 800W, we can choose the following specifications of PV panels.

Maximum power (Pmax)| 80 W| The number of PV panels connected in series for each group:

MPPT→2 PCS(2*21.6V<60V)

Total number of PV panels: 10PCS→800W/80W=10(PCS)

A number of groups that can be connected in parallel:

MPPT →5 groups (10/2 = 5 groups)

---|---|---
Rated voltage Vpm(V)| 18 V
Rated current Ipm(A)| 4 . 46 A
Open circuit voltage Voc(V)| 21 . 6 V
Short circuit current Isc(A)| 4 . 8 A

The configuration scheme of the 12 V inverter is:
Every 2 PV panels are connected in series to form a group, and connected to 5 groups of PV panels.

10 PV panels are connected in parallel to the inverter.

WWW.POWERSOLID.VN.