POWER SOLID PS-PGU1000V2B7T Line Interactive Gaming UPS User Manual
- June 10, 2024
- POWER SOLID
Table of Contents
PS-PGU1000V2B7T Line Interactive Gaming UPS
User Manual
PS-PGU1000V2B7T Line Interactive Gaming UPS
LCD DISPLAYS ON NORMAL MODE
Display interface is one page only, digital tube shows the input voltage and
output voltage on the left and right sides It will show the input voltage and
output voltage all the time in normal. If the ups fault, voltage parameters
are displayed for 7s, then alarm information is displayed for 3s.
Left digital tube | Alarm Cause | Right digital tube |
---|---|---|
ALA | Battery Voltage Too Low | 27 |
Battery Voltage Too High | 28 | |
Overload | 31 | |
Load time is enough to shut down | 32 | |
Standard Model UPS With Loading 2 hours or Countdown of plan Shutdown time |
33
In the event of UPS failure, please check the following and then contact your sales representatives:
- Whether the UPS power cord i properly connected
- Whether the output fuse is blown.
- Make sure the input voltage is compatible with this UPS system
When you call for services, please provide the following information
- The UPS type, series no.of UPS.
- The date of problem appearance.
- Explanation of the problem.
SPECIFICATIONS
MODEL | PS-PGU1000V#2B7T |
---|---|
Input | Voltage |
Frequency | 50Hz or 60Hz +6% |
Output | Frequency |
Voltage | 220Vac ( ±5% Adjustable) |
Transfer time | <10msec (10 msec on system check) |
Wave form | Sine wave under municipal supply, square wave under battery |
operation
Protection| Load input| Fuse for overload & short circuit protection
Short circuit| Fuse & current Limited & cut off
Battery| Backup time| 15-35 mins depend on the load
Type| Sealed Lead-Acid battery
Protection| Auto-inspection, discharge protection and battery fault caution
Battery| Normally battery is charge once three months; it isn’t less than 6
hours once a time.
Audible Alarm| Battery supply power| Sufficient battery capacity, buzzer rings
every 6 seconds red light flash
Insufficient battery capacity, buzzer rings every 1 second, red light flashing
Battery low Voltage or Overload/short circuit| Buzzer keep rings, red light on
Continuously
INTRODUCTION
A UPS is an advanced line interactive uninterruptible power system that is designed to protect your equipment like computers and telecommunication systems blackout when power oft. Under normal power condition, the UPS fi ters out all small fluctuations. During electrical power failure the unit immediately switches to it’s internal battery for continued power feed to the equipment it is linked to, thus allowing the system to be shutdown correctly which, for example on a computer would prevent files from being left open and resulting corruption.
EASY OPERATION GUIDELINES
-
Plug the power cord from the UPS into a wall outlet. Paying attention to satisfy that the voltage, frequency of the input power that must be suitable for the UPS.
CAUTION
Charge the battery for at least 8 hours before using the UPS. Battery wil self-charge if only the UPS s connected 2. Tum the main switch on (press & hold for 2 seconds.) -
Plug the power cord of the system to be protected (e.g. computer, monitor.etc.) into the outlet of back panel and turn on the power.
Do not connect laser printer to the UPS. This is because the laser printers voltage load from these devices is very high and may cause a higher drain from the UPS than expected! -
Ensure that the UPS is neither exposed to extremes of temperatures noris placed in direct sunlight when in operation
INSTALLATION
IMPORTANT
The new UPS must be charged for at least 8 hours before use
- Please make sure the UPS has no visible damage. Your UPS should include the following within the shipping box The UPS/User’s manual/AC fuses (for replacement)
- Plug the computer power cord into UPS outlet
OPERATION
- Turn on the UPS from the front panel at least 2 seconds
- After the UPS has been switched on, the green light on.
- If you wish to test UPS, you may tum offthe input voltage to the UPS system. With the devices attached, the buzzer alarm on the UPS red light will on—the UPS is now on reserve power from its internal battery.
- After completing the above test, please plug back the power cord of UPS into the wall socket!
LED INDICATOR AND BUZZER WARNING
-
The LCD display
-
ups nf off button
-
USB port
a. Output DC5V 2.4A Max
b. Configuration port -
LED color-changing breathing light
TROUBLES SHOOTING
The following table provides list of trouble shooting tips
PROBLEMS | POSSIBLE CAUSES | SOLUTIONS |
---|---|---|
LED not glowing | Input power fault | Check input power |
Fuse on the board and rear panel | Change the fuse and reset | |
Time pressing key to open UPS is too short | Pressing “OPEN” must be over 3 |
seconds
Without utility power indicator, alarm beeps every 6 seconds| Power failed|
Check input power
Fuse on board and rear panel| Change the fuse and reset
Red LED light is on, beeping constantly| Overload/battery voltage is too low|
Reduced load/charge UPS/call for service
Battery discharge is less than the standard| Battery charge not enough| After
recharging 8 hours continuously, then test discharge time. If the trouble
can’t be solved yet, call for service
Battery fault
Charge fault
LCD panel
LCD FAULT DISPLAY
Error Code Shows After UPS Power Off
Err | Phenomena | Code |
---|---|---|
Short Circuit or Wrong Phase Setting | 134 | |
Battery Low | 105 | |
Overload | 102 | |
Full load running time is approaching, UPS is about to shut down | 123 | |
Inverter Output Low | 104 |
Read User Manual Online (PDF format)