Product Information

The AL011 is a wireless door sensor alarm kit that includes an external structure, internal structure, 110Db speaker, status light, alarm, battery compartment, remote control, and indicator light. It operates at a frequency of 433.92 MHz.

Product Usage Instructions

  1. Ensure that the external and internal structures are properly installed on the door.
  2. Insert batteries into the battery compartment.
  3. Press and hold the pairing button on the internal structure until the status light flashes.
  4. Press and hold the pairing button on the remote control until the status light on the internal structure turns on. Repeat this step for any additional remote controls that need to be paired.
  5. Once pairing is complete, replace the cover on the internal structure.
  6. Refer to the provided image for the naming of the four alarms (A, B, C, and D) and the two remote controls (a and b).
  7. Remote control a control alarms A, B, and C, while remote control b controls alarms C and D.
  8. Press the button on the remote control once to activate the door sensor alarm. Press it again to turn it off.
  9. If the battery power is low, an alert will be given. Replace the batteries as soon as possible.

Product presentation

ARREGUI-AL011-Magnetic-Door-Alarm-fig-1

Product kit

The magnetic door alarm system with vibration sensor consists of the following elements, all of which are included in the product kit:

  • 1 instruction manual
  • 1 door alarm
  • 1 magnetic sensor
  • 1 remote control
  • 2 AAA batteries
  • 1 CR2032 battery
  • 3M adhesive

Start-up

Pairing the alarm and remote control

ARREGUI-AL011-Magnetic-Door-Alarm-fig-2

  • Step 1: Press the SET button located inside the alarm body. The LED light will turn on.
  • Step 2: Press any button on the remote control to establish a connection.
    • The alarm will emit 2 beeps. This indicates that the alarm has been successfully paired with the remote control.
  • Step 3: Repeat the previous 2 steps to pair the remote controls as needed.

Unpairing the alarm and remote control: Press and hold the SET button for 8 seconds. The red light will flash intermittently and then switch off. This indicates that the alarm has been unpaired from the remote control.

  • Once all the devices have been paired, put the cover back on.

Refer to the image and note that the 4 alarms are named A, B, C and D, and the 2 remote controls are a, and b. The remote control only controls the door sensors that have been paired with it. Thus, you can connect alarms A, B and C with remote control “a”, and alarms C and D with remote control “b”. Remote controls “a” and “b” control alarm C without interfering with each other.

User manual

  • Activating the alarm: Press the button on your remote control, always with the door closed. Once activated, if the door opens, the alarm will sound for 30 seconds.
  • Deactivating the alarm: Press the button on the remote control. The SOS function will remain active even if disconnected.
  • SOS function: If the SOS button is pressed in any situation, the alarm will sound for 30 seconds.
  • Function button : With the alarm disconnected :
    • Function 1: Ding-dong (doorbell) )) Press once .To repeat this function: > To move to the next function, press again .
    • Function 2: High-pitched door opened alarm. If the door is opened, a high-pitched alarm will sound, which will cease when the door is closed. To repeat this function: > >. To move to the next function, press again .
    • Function 3: Beeping door opened alarm. If the door is opened, 2 tones (3 beeps per tone) will sound, which will cease when the door is closed. To repeat this function: > . To go back to function 1, press again .

Troubleshooting

  • If the alarm does not detect the magnetic sensor when is pressed to activate the alarm, it will emit around 10 beeps.
  • Adjust the distance between the sensor and the alarm to fix the problem.

Installation

ARREGUI-AL011-Magnetic-Door-Alarm-fig-8

  • Place the adhesive on the back of both the alarm and the magnetic sensor and attach them to the door, taking special care that the indicated triangles face each other at the same height, at a distance of no greater than 15 mm between them.

Low power warning

  • When the battery voltage is below 2.1 V, it will emit a beep. When this happens, replace the batteries as soon as possible.

Changing the batteries

  • Release the rear cover of the alarm, sliding it upwards until it is completely uncovered to access the electronic system:
  • Place 2 AAA batteries for the alarm operation.

Specifications

  • Frequency: 433,92 MHz
  • Ambient humidity: <90%
  • Operating temperature: -10ºC to 60ºC
  • Decibelios: 110 db
  • Battery type (alarm): 2 x AAA
  • Battery type (remote control): 1 x CR2032
  • Range of remote control B (without barriers): approx.15 mts
  • Alarm battery life at rest: 1 year
  • Remote control battery life at rest: 1 year
  • Alarm weight: 60g
  • Remote control weight: 15g
  • Alarm dimensions: 90x43x13mm
  • Magnetic sensor: 45x13x13mm
  • Remote control dimensions: 61x33x10mm

EU DECLARATION OF COMPLIANCE MADE SIMPLE ACCORDING TO DIRECTIVES 2014/53/EU (EMC) AND 2015/863/EU (ROHS)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals