ATAG 3319471 NEOZ System Interface Installation Guide

June 10, 2024
ATAG

ATAG 3319471 NEOZ System Interface

ATAG 3319471 NEOZ System Interface

OVERVIEW

The ATAG NEOZ system interface offers simple and efficient room temperature adjustment and domestic hot water control.

SAFETY RULES

WARNING!

The following manual is an integral and essential part of the product and must always be kept with care and attached to the product, even if it is transferred to another owner or user, or when it is used with a different application.

Do not use the product for any purpose other than that specified in this manual. The manufacturer is not liable for damage resulting from improper use of the product or failure to install it as instructed herein. All maintenance on the product must be carried out exclusively by qualified staff using solely original spare parts. The manufacturer is not liable for damage resulting from failure to observe this instruction, which may compromise the safety of the installation.

WARNING!

The appliance can be used by children older than 8 years and by people with reduced physical, sensory or mental abilities, or who lack adequate experience and the necessary knowledge, provided that they are supervised or have been instructed on how to use the appliance safely and on understanding the attendant risks.
Children must not play with the appliance. Any cleaning and maintenance which should be performed by the user must not be done by unsupervised children.

SYMBOL LEGEND:

**** Failure to comply with this warning entails the risk of injury to persons, which in some circumstances may be fatal.

Failure to comply with this warning may result in serious damage to property and plants or injury to animals.

The manufacturer is not liable for damage resulting from improper use of the product or failure to install it as instructed herein.
Do not perform operations that involve removing the appliance from its installation location.

Damage to the device.

**** Do not climb onto chairs, stools, ladders or unstable supports to clean the device.
Personal injury caused by falling from a height or shearing (stepladders shutting accidentally).

Do not use any insecticides, solvents or aggressive detergents to clean the appliance.
Damage to plastic or painted parts.

**** Do not use the appliance for any purpose other than normal domestic use.
Damage to the device caused by operation overload.
Damage to objects caused by improper use.

Do not allow children or inexperienced people to operate the appliance.
Damage to the appliance due to improper use.

**** During the cleaning, maintenance and connection operations, it is necessary to isolate the appliance from the mains supply by removing the plug from the socket.
Personal injury due to electrocution.

PRODUCT IN COMPLIANCE WITH EU DIRECTIVE 2012/19/EU

The barred wheeled bin symbol appearing on the appliance or on its packaging indicates that the product must be collected separately from other waste at the end of its useful life.
The user must therefore deliver the decommissioned product to an appropriate local facility for separate collection of electrotechnical and electronic waste. Alternatively, the appliance to be scrapped can be delivered to the dealer when purchasing a new equivalent appliance. Electronic products for disposal measuring less than 25 cm can also be delivered free of charge to electronic equipment dealers having a surface area of at least 400 m2 , without having to purchase other products. Proper separated collection of the decommissioned appliance for its subsequent recycling, treatment and eco- compatible disposal helps to prevent negative effects on the environment and human health, besides encouraging reuse and/or recycling of its constituent materials.

PRODUCT DESCRIPTION

TECHNICAL DATA

Dimensions| 134 mm x 96 mm x 21 mm
Power supply| ATAG Zone BUS 8 to 24V max
Current draw| ≤35mA
Operating temperature| -0 ÷ 50°C
Storage temperature| -10 ÷ 45°C
Humidity| 20% RH ÷ 80% RH
Temperature reading precision| +/- 0,5°C
Buffer memory duration| min 2h
Bus cable length and cross-sectional area| max. 50 m    ø min. 0.5 mm²
NOTE: IN ORDER TO AVOID INTERFERENCE PROBLEMS, USE A SHIELDED CABLE OR TWISTED PAIR CABLE.
PRODUCT TECHNICAL SHEET

Supplier name| ATAG
Supplier identification model| ATAG NEOZ
Temperature control class| V
Energy efficiency contribution (%) for space heating| +3%
Addition of an ATAG External Sensor:
Temperature control class| VI
Energy efficiency contribution (%) for space heating| +4%
In a system with 3 zones with 2 ATAG Room Sensors:
Temperature control class| VIII
Energy efficiency contribution (%) for space heating| +5%

Dimensions

INSTALLING THE PRODUCT

The device detects the room temperature, therefore several factors should be taken into account when choosing an installation site. Position the device far from heat sources (radiators, sunlight, fireplaces, etc.) and from draughts, doorways and windows which could affect the temperature readings. It should be installed approximately 1.5 metres above the floor level.

WARNING!

Installation should be performed by a qualified technician. Before making any connections, shut off the electricity power supply to the heat generator via its external two-position switch. Install the product in a room with a normal level of pollution.

WALL INSTALLATION|
---|---
Connect the pair of wires to the terminal block to connect to the heat generator via BUS| Installing The Product
Fix the base plate contained in the installation kit to the wall| Installing
The Product
Position the ATAG NEOZ onto the base plate and push it delicately downwards.| Installing The Product
CONNECTION TO THE SYSTEM

The sending, receiving and decoding of signals occurs through the Bridge Net® BUS protocol, which puts the heat generator and the system interface into contact with each other

Connect a pair of wires to the BUS connector on the heat generator P.C.B.| Installing The Product
The electrical connection of the device is not polarized.

NOTE: IN ORDER TO AVOID INTERFERENCE PROBLEMS, USE A SHIELDED CABLE OR TWISTED PAIR CABLE.

NOTE 2: Connect only one system interface to the BUS network

INITIAL CONFIGURATION

WARNING!

To guarantee safety and correct operation of the system interface, it must be commissioned by a qualified technician in possession of the skills as required by law.

CONFIGURATION PROCEDURE

Initialization| Insert the system interface into the connection shoe by pushing it gently downwards and making sure that the products are powered; after a brief initialization, the device will be ready to be configured.
Selecting the language| The display screen shows “Language”. Select the language by rotating the knob. Press OK to confirm
Selecting date and time| The display shows the “Time & Date”. Turn the knob to select day, month and year. For each selection, press the knob to confirm.
Once the date is set, the selection moves to setting the time.

Turn the knob to set the correct time; for each selection, press the knob to confirm.

Selecting the mode daylight saving time| Once the date is set, the selection moves to the daylight saving time setting. Turn the knob to select TIME PROGRAM or MANUAL.

If you want the system to automatically update the period when daylight sav- ing time is in use, select TIME PROGRAM. Press the knob to confirm.

Selecting the zones “Zones” Menu| This screen is used to select the hydraulic zones to be displayed in the “Zones” user menu. Turn the knob to select the zones in the system and press the knob to confirm.
Setting the “Zone” parameters| For devices compatible with this function, you can set the following param- eters for the selected Zone:

  • Operating mode: Manual/Programmed/Off;
  • Zone Name (only for compatible devices);
  •  Room temperature Setpoint;
  • Heating Controller (only for compatible devices) set the type of device associated with the zone being heated:
  • none
  • room sensor
  • thermostat;
  • Cooling Controller (only for compatible devices) set the type of device associated with the zone being cooled:
  • none
  • room sensor
  • thermostat;

Selecting the zone| After, the display screen shows the selection of the zone to be assigned to the room temperature control device.

Turn the knob to select the desired zone. Press the knob to confirm. By as- signing zone no. 0 the device will exclusively carry out the function of system interface. After the zone selection, the system will repeat the initialization procedure

WARNING!
BUS ADDRESSING CONFLICT
After initialization, if the zone assigned to the device is already being used by another device on the BUS network, an addressing conflict error message will be displayed. Press the knob to access the configuration page of the BridgeNet Bus network. Proceed with the correct addressing of the devices according to the instructions in the respective manuals.

WARNING!
TIME SCHEDULING CONFLICT
A time scheduling conflict error is generated when one of the programmable devices on the network does not support multi-level programming.
In this case, the programming must be set on “2 levels” through the 0.4.3. parameter.

WARNING!
ROOM TEMPERATURE CORRECTION
In the event of installation on a wall-mounted Remote Modem (Light Gateway), the room temperature measurement may require a correction.

START SCREEN

Overview

A. Menu button
B. Knob (turn to select / press to confirm)
C. Esc button (back)
D. Function Icons
E. Weather and Outdoor temperature
F. Room temperature
G. Desired temperature
H. Date and Time
I. Operation icons
L. Pressure indication

| Wi-Fi module update in progress
---|---
| Access Point Opening in progress
| Wi-Fi Off or not connected
| Wi-Fi connected but internet access failed
| Wi-Fi active
| Outdoor temperature
| Flame present
| Optimum boiler efficiency
| Solar heating module connected
| Photovoltaic contact enabled
| Photovoltaic contact active
| Smart Grid system enabled
| Supplementary heating elements not enabled
| Number of heating element stages active
| Heat pump active
| Room set-point extension active
| Heating
| Heating active
| Domestic hot water
| Domestic hot water active
| Cooling service enabled
| Cooling service active
| Relative humidity index
| Programmed
| Manual
| Temperature regulation function active

| Holiday function active
| Domestic hot water Boost function enabled
| Hot water comfort enabled in electricity reduced band rate

HC 40

| Hot water comfort enabled in electricity reduced band rate and domestic hot water set-point at 40°C in electricity full band rate
| Test mode active
| Thermal sanitation function active
| Anti-frost function active
| Dehumidification function active
| Silent mode active (only for heat pumps)
| Error in progress

BASIC FUNCTIONS

Basic Functions Interface

Room temperature regulation in Manual mode

The operating mode of the zone associated with the device is set to “ ” MANUAL.
Turn the knob to select the temperature value indicated on the display using the movable cursor close to the ring.
Press the knob to confirm.
The display shows the set temperature.

Room temperature adjustment in Programmed mode

Basic Functions Interface

The operating mode of the zone associated with the device is set to “ ” PROGRAMMED.
During operation in scheduled programming mode, the set room temperature can be changed temporarily. Turn the knob to select the temperature value indicated using the movable cursor close to the ring.
Press the knob to confirm.
The display shows the set temperature.
Turn the knob to set the time at which you want the change to end. Press the knob to confirm. The “ ” symbol appears on the display.
The system interface will maintain the temperature value until the set time, after which  the pre-set room temperature is restored.

Room temperature adjustment with SCI on.

If the heating (or cooling) hot water temperature does not match the desired value, it can be increased or decreased via the “Heating Settings” (or Cooling settings). The correction bar will appear on the display. Press the knob to confirm, or press the back button to return to the previous screen without saving.

USER MENU

Press the Menu button; the display will show the user menu consisting of two pages. To enter the second page, turn the knob and scroll down to the last icon of the first page

Zones
Allows you to check the main information on the operating status of the zones and to set the operating mode of the single zone.

Time scheduling
This allows you to set the time scheduling for heating, cooling, hot water and buffer (if present). Choose the operating type:

Energy Consumption
Shows the estimated energy consumption (gas and electricity) and their performance over time for the heating, cooling and domestic hot water modes.

Holiday function
The holiday function disables heating during the holiday period and activates the anti-frost protection for the room heating system and the DHW storage tank until the set date.

Operating mode
Selects the system operating mode

SUMMER
domestic hot water produced, heating of

WINTER
domestic hot water produced, heating on.

HEATING ONLY
excluding cylinder heating (if present).

COOLING AND DOMESTIC HOT
WATER (if present)

**** COOLING ONLY excluding cylinder heating (if present)

OFF
system off, anti-frost function enabled.

Domestic Hot Water settings
Allows you to select the desired temperature, the operating mode for hot water production and the thermal sanitization function of a DHW tank (if present).

Impostazioni Fireplace
When the function is activated, it regulates the request for heat in the zone associated with the device based on the external temperature until the selected time. When the function is active, the indoor temperature of the room does not affect the request for heat.
In order to enable the function, there needs to be an external temperature probe in the system or, if available, the internet weather report needs to be active (see Connectivity menu).

Connectivity
Allows you to enter the settings of the remote connection service when a WiFi device is connected to the bus and allows you to consult the main diagnostics information.

System Information
Allows you to consult the main diagnostics information (of the connected devices), and the energy efficiency performance of the system.

Screen Settings
Allows you to configure the main display settings.

Advanced Settings
Allows you to access the following functions:

  • Heating Temperature Regulation
  • Cooling Temperature Regulation
  • Buffer Settings
  • Advanced settings of the connected devices (boiler, heat pump, hybrid…)
  • Units of Measurement
  • Photovoltaic integration
  • Setting the units of measurement
  • Measured temperature correction
  • Selecting the zones to be displayed in the “Zone” menu

TECHNICAL AREA

WARNING!
To guarantee safety and correct operation of the system interface, it must be commissioned by a qualified technician in possession of the skills as required by law.

To enter the technical area simultaneously press the “Esc” and “Menu” buttons until “Enter code” appears on the display.
Turn the knob and insert the technical code (007) and press to confirm.

Technical area

Language| Language setting
Time & Date| Date & Time setting
Bridge Net Bus network setting| Show the connected devices and their features
Zone mode| Zone control advanced settings
Complete Menu| Access to all menus and technical parameters enabled according to the connected devices and available zones
Guided procedures| Dedicated menu for guided procedures for setting the devices included in the system
Service| Quick access to the service parameters for the technician
Faults| List of the last 10 detected errors

IMPORTANT!:
For more details on the setting of the parameters and procedures of the technical area please refer to the installation manual of the single products (boilers, heat pumps and hybrid systems, etc.).

| Compliance| EMC: 2014/30/EU RED: 2014/53/EU ROHS: 2015/863/EU
---|---|---
Standard| EMC: EN 55014-1:2017; EN 55014-2:2015; CISPR 14-1:2016; CISPR 14-2:2015

RED: ETSI EN 300 328: v2.2.2; ETSI EN 301 489-1: v2.2.3; ETSI EN 301 489-17: v3.2.2; EN 62311:2008; EN 62368-1:2014+A11:2017

ROHS: EN 50581

| Compliance| EEMC: Electromagnetic Compatibility Regulations 2016 RED: Radio Equipment Regulations 2017

ROHS: Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012

Standard| EMC: BS EN 55014-1:2017; BS EN 55014-2:2015; CISPR 14-1:2016; CISPR 14-2:2015

RED: ETSI EN 300 328: v2.2.2; ETSI EN 301 489-1: v2.2.3; ETSI EN 301 489-17: v3.2.2; BS EN 62311:2008; BS EN 62368-1:2014+A11:2017

ROHS: BS EN 50581

CUSTOMER SUPPORT

Postbus105 • 7130 AC Lichtenvoorde • www.atagheating.com

ATAG Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ATAG User Manuals

Related Manuals