WellWorks FDIR-V4 Infrared Thermometer Forehead & Ear User Manual

June 6, 2024
WellWorks

WellWorks - logoInfrared Thermometer Forehead & Ear
Model #: FDIR-V4 User Manual
version: V1
Please read this instruction manual thoroughly before operating and retain for future use.

Safety Precautions

Warning

  • Use of this thermometer is not intended as a substitute for consultation with your physician. It is dangerous for a user to perform a self-evaluation and self-treatment based on the measured result. Be sure to follow doctor’s instructions.
  • Keep the thermometer out of reach of children. In case batteries or other components are swallowed, please consult your doctor immediately.
  • Don’t throw the battery into fire.

Notice

  • The device is a precision instrument; don’t drop, trample or impose any vibration or impact on the thermometer.
  • Do not touch the lens of the probe with your fingers and do not disassemble the device by yourself.
  • Before measuring temperature, make sure to remove hair and ensure the measuring surface is clean and dry.
  • Do not use within 30 minutes of exercise, eating, or bathing. Allow 30 minutes to pass before taking temperature.
  • To ensure accuracy, if the ambient temperature varies, keep the device in a stable temperature setting for 30 minutes before use.
  • For accuracy, do not take more than 3 consecutive temperature readings. Allow at least 1-minute before subsequent temperature taking.
  • Avoid measuring skin areas with scarred tissue or skin disorders of any kind.
  • Do not measure a person’s forehead if they have suffered trauma on the forehead.
  • Do not measure if the patient is treated with certain drug therapies.
  • Do not measure when the measuring sites (forehead) are exposed to direct sunlight, fireplace heat, cold compress therapies, or air conditioner flow. Please wait for 30 minutes to measure.
  • Do not immerse the device in water or expose it to direct sunlight.
  • Make sure the measuring distance is between 1-6cm.
  • Do not use a mobile device or cordless phone near the thermometer when measuring.

Package Contents

Quantity Parts
1pc Thermometer
1pc User Manual

Installing/Replacing Battery

  • Remove the battery cover by sliding it toward the bottom of the thermometer.
  • Insert or replace 2 x 1.5 AAA batteries into the battery compartment, ensuring to match the indicating polarity symbols. (always use new batteries).
  • Place the battery cover on the thermometer back in place so it snaps closed.

WellWorks FDIR-V4 Infrared Thermometer Forehead amp Ear - snaps
closed

Product Specification

LCD Display Description

WellWorks FDIR-V4 Infrared Thermometer Forehead amp Ear - registered
2

Features

Modern & Sleek Design

  • State of the art design with high-quality sensor

High Accuracy

  • This product has passed performance standards and has a variance of no more than ±0.5°F (0.3°C)

Power Saving Function

  • Automatic shut-off mode in approximately 8s

Large LED Screen

  • Illuminates for an easy to see display

Fever Alarm “Beeping”

  • Normal: 32.0℃ (89.6 ℉) ≤ T ≤ 37.4℃ (99.3 ℉) – will hear 1 “beep”
  • High: 37.5℃ (99.5 ℉) ≤ T ≤ 38.5℃ (101.3 ℉) – will hear 2 “beeps”
  • Very High: 38.6℃ (101.5 ℉) ≤ T ≤ 42.9℃ (109.2 ℉) – will hear  4 “beeps”

Instructions for Use

6.1 Power on – insert batteries into the battery compartment. Press the power/scan button to turn it on. The product will start self-inspection.
6.2 Measurement unit selection – When the product is powered off, press and hold the scan button for 8 seconds. The measurement system (°C or °F) automatically appears on the display.

WellWorks FDIR-V4 Infrared Thermometer Forehead amp Ear -
displayTo toggle between °C or °F, continue holding the scan button for 2 seconds. Release the button when your desired unit is showing.

WellWorks FDIR-V4 Infrared Thermometer Forehead amp Ear - toggle
between6.3 Measure site select – Put the probe cover on for forehead mode or remove it for ear mode.WellWorks FDIR-V4 Infrared Thermometer Forehead amp Ear - Measure
site select Tip: A clean, dry forehead is important. Remove makeup, dry sweat, and move hair to ensure an accurate measurement. Do not use outdoors.

6.4 Forehead temperature measure – Ensure the probe cover is on. Hold the device steadily from 1-6cm / 0.4” – 2.4” from the forehead.
Press the scan button lightly. When you hear the “beep”, the measurement has registered and you can check the result.

WellWorks FDIR-V4 Infrared Thermometer Forehead amp Ear -
beep6.5 Ear temperature measure – Ensure the probe cover is off. Gently insert the probe into the ear. Press the scan button lightly. When you hear the “beep”, the measurement has registered and you can check the result.WellWorks FDIR-V4 Infrared
Thermometer Forehead amp Ear - registered

Tip: For accuracy, ensure you take the temperature in the same ear each time. Other factors may influence measurements, such as:

  • Obstructions or ear wax build-up
  • Having just had ears covered (with hats, earmuffs, etc…)
  • Exposure to hot or cold outdoor or indoor temperatures
  • Having recently gone swimming or taken a bath
  • For accuracy, ensure the user has been in ambient temperate for at least 30 minutes prior to taking temperature.

Temperature Test Information

  • If the temperature range is 32.0℃ (89.6 ℉) ≤ T ≤ 37.4℃ (99.3 ℉), you will hear 1 “beep” to signal a normal temperature.
  • If the temperature range is 37.5℃ (99.5 ℉) ≤ T ≤ 38.5℃ (101.3 ℉), you will hear 2 “beeps” to signal a high temperature.
  • If the temperature range is 38.6℃ (101.5 ℉) ≤ T ≤ 42.9℃ (109.2 ℉), you will hear 4 “beeps” to signal a very high temperature.

Care & Cleaning

  • Sensor Lens – Keep the lens sensor clean to ensure accuracy. To clean, very gently wipe the surface with a cotton swab or soft cloth moistened with isopropyl alcohol (75%) and dry.
  • Unit Body & Display – Use a soft, dry cloth to clean the thermometer display and unit body. If very dirty, use a soft cloth moistened with alcohol and dry.
  • Do not use abrasive cleaners. Do not use other methods to disinfect. Do not immerse in water.

Maintenance

  • We do not authorize any institution or individual to maintain or repair the product.
  • Do not attempt any repairs to the device on your own.}
  • Any such non-authorized repair efforts by unauthorized agencies will nullify and terminate any claim made under warranty.

Specifications

D evice Name Infrared Thermometer
Model FDIR-V4
Measurement Site Forehead & Ear
Measurement Time About 1 second
Power Supply d.c.3V, 2×1.5V AAA batteries
Measuring Range 89.6°F -109.2°F (32.0-42.9°C)
Measuring Accuracy 35.0°C – 42.0°C ± 0.2°C (95.0°F – 107.6°F ± 0.4°F) Outside

this range: ± 0.3°C (±0.5°F)
Clinical Repeatability| Within ±0.5°F/0.3°C
Resolution of Display| 0.1°C/0.1°F
Operation Condition Temperature| Temperature: 50.0 °F – 104.0 °F (10.0 °C – 40.0 °C)
Relative humidity: 15 – 95% Atmospheric pressure: 70 kPa – 106 kPa
Storage Condition & Size| 143 x 38 x 44 mm
Weight| 85g
Weight with Batteries| 96g
Transport/Storage Condition Temperature| Temperature: -13.0 °F – 131.0 °F (-25.0 °C – 55.0 °C)
Relative humidity: 15 – 95% Atmospheric pressure: 70 kPa – 106 kPa
High Body Temperature Alert| ≥99.6°F (≥37.6°C)

Troubleshooting

Trouble or Error Message| Station|

Solution

---|---|---
No response| Batteres are dead| Replace with new batteries
Battery in wrong polarity or type| Remove batteries and replace them with new cries et remove batteries and re-insert them
Poor battery contact
| Ambient temperature is beyond the range of measurement| Keep the Verrone: et for at lea     33 mates Ina room there the temperature e 50C-104T or Kit-40’0
The SECISOt or hardware is damaged| The device needs rep
| Temperature is accurate due to extreme
changes in the room setting| Leave the device in ambient temperature for at
least 30 minutes and re-measure
In forehead mode
Temperature readings are too close together
Temperature reading is above log if 142 9’0| Mow 30 rrvnutes to pass and re-measure. For lii or to temperatures `re
” the is device used properly as per the manual. please seek medical attention
| Hal a sweat has obstructed the measurement reading
In forehead mode
Measurement distance was too far Temperature reading is below 8g 61132 00
| Low battery. but stiff OK to use.| Continue use but prepare to replace the batteries
| Low battery not OK to continue use.| Replace the batteries
| Hardware is damaged.| Reasecortact distributor for support

Warranty

Leda Health Innovations Inc. warrants its products to be free from defects in material and workmanship for a period of (1 Year) from the date of purchase. Should the product prove to be defective at any time during the warranty period, we would either replace or repair the product at our option without charge. After the warranty period, a service charge will apply for the replacement of parts and labor costs. To obtain warranty service, you must return the product complete with its original parts & accessories along with a copy of the original purchase, gift, or registry receipt to us. This warranty does not cover damage caused by any tampering, accident, misuse, abuse, improper maintenance, unauthorized modification, or connection to an improper power supply. This warranty excludes all incidental or consequential damages and any liability other than stated above.
Imported & Distributed by:
Leda Health Innovations Inc.
Address: 401 Norfinch Drive, Toronto, Ontario, M3N 1Y7, Canada
Tel: 905-856-1144
• Fax: 416-739-9090
• Website: www.bywellworks.com
Made in China
Famidoc Technology Co., Ltd.
Address: No. 212 Yilong Road, Hexi Industrial Zone, Jinxia, Changan Town, Dongguan 523853, Guangdong Province, P.R. China.

Name: Shanghai International Holding Corp. GmbH (Europe)
Dimdi No.: DE/0000040627
Address: Eiffestrasse 80, 20537 Hamburg, Germany

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals