INSTALLATION MANUAL
NATURAL GAS MODELS: BL36NTEA-1 / BL46NTEA
Ascent™ Linear Series (BL46 illustrated)
FOR INDOOR USE ONLY
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
**WARNING
FIRE OR EXPLOSION HAZARD**
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
– Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
– Installation and service must be performed by a qualified installer, service agency, or the supplier.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller
Drive, Crittenden, Kentucky, USA, 41030
Phone 1 866-820-8686 •
www.napoleon.com • hearth@napoleon.
PLACE SERIAL NUMBER LABEL ON THE OWNER’S MANUAL
**WARNING**
-
This appliance is hot when operated and can cause severe burns if contacted.
-
Any changes or alterations to this appliance or its controls can be dangerous and is prohibited.
-
Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fire or injury.
-
Ensure the glass door is opened or removed when lighting the pilot for the first time and when the gas supply has run out.
-
Risk of fi re or asphyxiation, do not operate appliance with fixed glass removed and never obstruct the front opening of the appliance.
-
Do not connect 110 volts to the control valve, with the excetion of models; GSST8 and GT8.
-
Risk of burns. ! AVERTISSEMENT
-
Do not install damaged, incomplete or substitute components.
-
Risk of cuts and abrasions. Wear protective gloves, protective footwear, and safety glasses during installation. Sheet metal edges may be sharp.
-
Do not burn wood or other materials in this appliance.
-
Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the appliance.
-
High pressure will damage valve. Disconnect gas supply piping before pressure testing gas line at test pressures above 1/2 psig. Close the manual shut-off valve before pressure testing gas line at test pressures equal to or less than 1/2 psig (35mb).
-
The appliance must not be operated at temperatures below freezing (32°F / 0°C). Allow the appliance to warm to above freezing prior to operation, with the exception of models; GSS36, GSS42; these appliances are suitable for 0°F / -18°C.
-
Children and adults should be alerted to hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
-
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to an appliance or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
-
Clothing or other flammable material should not be placed on or near the appliance.
-
Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
-
Furniture or other objects must be kept a minimum of 4 feet (1.22m) away from the front of the appliance.
-
Ensure you have incorporated adequate safety measures to protect infants/toddlers from touching hot surfaces.
-
Even after the appliance is off, it will remain hot for an extended period of time.
-
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the
floor. -
Any safety screen, guard or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
-
It is imperative that the control compartments, burners and circulating blower and its passageway in the appliance and venting system are kept clean. The appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids. If the appliance shuts off, do not re-light until you provide fresh air. If appliance keeps shutting off, have it serviced. Keep burner and control compartment clean.
-
Under no circumstances should this appliance be modified.
-
Do not allow wind or fans to blow directly into the appliance. Avoid any drafts that alter burner flame patterns.
**DANGER
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is
provided with this appliance and must be installed for the protection of
children and other at-risk
individuals.
WARNING**
-
Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this appliance.
-
This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.
-
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
-
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualifi ed service person, if equipped.
-
Do not strike or slam shut the appliance glass door, if equipped. Electric
-
Only doors / optional fronts certified with the appliance are to be installed on the appliance.
-
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all plastic bags, these are not toys and should be kept away from children and infants.
-
Carbon or soot should not occur in a vent free appliance as it can distribute into the living area of you home. If you notice any signs of carbon or soot, immediately turn off your appliance and arrange to have it serviced by a qualified technician before operating it again.
-
If equipped, the screen must be in place (closed) when the appliance is in operation.
-
When equipped with pressure relief doors, they must be kept closed while the appliance is operating to prevent exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of the exhaust escaping through these openings can also cause the surrounding combustible materials to overheat and catch fire.
-
Carbon monoxide poisoning may lead to death; early signs of carbon monoxide poisoning resemble the fl u, with headache, dizziness and/or nausea. If you have these signs, the appliance may not be working properly. Get fresh air at once! Have appliance serviced. Some people; pregnant women, persons with heart or lung disease, anemia, those under the influence of alcohol, those at high altitudes are more affected by carbon monoxide than others. Failure to keep the primary air opening(s) of the burner(s) clean
may result in sooting and property damage. -
As with any combustion appliance, we recommend having your appliance regularly inspected and serviced as well as having a Carbon Monoxide Detector installed in the same area to defend you and your family against Carbon Monoxide (not applicable for outdoor appliances).
-
Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting, discoloration or damage to decorations, a TV or other electronic components.
-
For appliances equipped with a safety barrier; if the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
-
Installation and repair should be done by a qualified service person. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
-
For outdoor products only: this appliance must not be installed indoors or within any structure that prevents or inhibits the exhaust gases from dissipating in the outside atmosphere.
-
If applicable, the millivolt version of this appliance uses and requires a fast acting thermonuclear. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
**WARNING:
This product can expose you to chemicals including lead and lead compounds,
which are known to the State of California to cause cancer, and chemicals
including BBP and
DEHP,** which are known to the State of California to cause birth defects
or other reproductive harm. For more information, go to
www.P65Warnings.ca.gov.
WARNING
FIRE RISK HAZARD / DELAYED IGNITION
High supply pressure will damage the valve / controls.
Disconnect the appliance main gas valve/control from the supply piping when
pressure testing that system at pressures in excess of 1/2 psi (3.5 kPa).
General information
When the appliance is installed at elevations above 4,500ft (1372m), and in
the absence of specific recommendations from the local authority having
jurisdiction, the certified high altitude input rating shall be reduced at the
rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises
during heating up and cooling down cycles are normal
and are to be expected. Change in flame appearance from “HI” to “LO” is more
evident in natural gas than in propane.
This appliance is approved for bathroom, bedroom and bed-sitting room
installations and is certified for mobile home installation.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a
certified
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is
provided with the appliance and must be installed. The protective wrap on
plated parts is best removed when the assembly is at room temperature but this
can be improved if the assembly is warmed, using a hair dryer or similar heat
source.
This appliance is a decorative product. It is not a source of heat and not
intended to burn solid fuel.
Batteries must be disposed of according to the local laws and regulations.
Some batteries may be recycled, and may be accepted for disposal at your local
recycling center. Check with your municipality for recycling instructions.
1.1 rates and efficiencies
| BL36-1| BLAB
---|---|---
Fuel Type| Natural Gas| I Propane| Natural Gas| I Propane
Altitude (FT)| 0-4,500| 4,500
Max. Input (BTU/hr)| 17,500| 16,000| 24.000
Min. Input (BTU/hr)| 12.000| 12,500| 17,000
Min. Inlet Gas Supply Pressure| 4.5″ w.c. (11mb)| 11″ w.c. (27mb)| 4.5″ w.c.
(11mb)| 11″ w.c. (27mb)
Max. Inlet Gas Supply Pressure| 7″ w.c. (17mb)’| 13″ w.c. (32mb)| 7″ w.c.
(17mb)”| 13″ w.c. (32mb)
Manifold Pressure (Under Flow Confictions)| 3.5″ w.c. (9mb)| 10″ w.c. (25mb)|
3.5″ w.c. (9mb)| 10″ w.c. (25mb)
- Maximum inlet pressure not to exceed 13” w.c. (32mb).
1.2 installation checklist
GAS FIREPLACE INSTALLATION CHECKLIST
Customer:
Address:
Model:
Serial #| Date Installed:
Installer:
Dealer:
Dealer Phone #:
---|---
Fireplace Installation
Is the fireplace level and secured?
Are the factory supplied non-combustible materials installed?
Is the exterior wall insulated and dry-walled?
Are the clearances to combustibles maintained?
Are the logs/media installed as instructed?
Are the accessories installed as instructed?
Is the glass door properly sealed and unobstructed?
Is the safety barrier installed and secure?
Are all required accessories installed (i.e. door trims)?
Fireplace Installation | YES | IF NOT, PLEASE EXPLAIN WHY? |
---|---|---|
Is the fireplace level and secured? | **** | |
Are the factory supplied non-combustible materials installed? | **** | |
Is the exterior wall insulated and dry-walled? | **** | |
Are the clearances to combustibles maintained? | **** | |
Are the logs/media installed as instructed? | **** | |
Are the accessories installed as instructed? | **** | |
Is the glass door properly sealed and unobstructed? | **** | |
Is the safety barrier installed and secure? | **** | |
Are all required accessories installed (i.e. door trims)? | **** |
Venting Installation
Is the venting configuration within the parameters?| |
---|---|---
Has the venting been sealed with the appropriate sealant?| |
Is the venting supported and secured?| |
Are all clearances to combustibles maintained?| |
Are the appropriate firestops and shields properly installed?| |
Is the terminal, level, secured and sealed?| |
Gas and Electrica
Was the fireplace converted to propane?| |
---|---|---
Was the appropriate supply pressure verified?| |
Were all gas connections leak tested?| |
Is the 110 VAC supply connection to the fireplace compliant?| |
Are all electrical wires protected from damage?| ****|
Finishing
Non-combustible materials used as per instructions?| |
---|---|---
Enclosure instructions forwarded to builder/finisher?| |
Minimum enclosure dimensions compliant?| |
Combustible Mantle Clearances compliant?| |
Commissioning
Was the fireplace test fired and all operation verified?| |
---|---|---
Safety and lighting instructions reviewed with the Customer?| |
Operating Instruction Manual left with the Customer?| ****|
Wolf Steel Ltd. recommends photographs of the various stages of construction
be filed along with a copy of this completed form.
W415-3091 / C / 05.11.22
1.3 installation overview
Recommended installation steps:
-
Determine venting requirements before deciding the final location of the appliance.
-
Install rough framing (refer to “rough framing” section).
note:
For Universal Heat Management installation steps, refer to the leaflet provided with the Universal Heat
Management kit. Start Universal Heat Management installation before placing appliance in its final position. -
Place the appliance in its final position.
-
Install nailing tabs (refer to “nailing tab installation” section).
-
Install appliance venting (refer to “venting installation” section).
-
Install all electrical wirings (refer to “electrical information” section).
-
Install gas lines (refer to “gas installation” section).
-
Test appliance.
-
Complete framing (refer to “finish framing” section).
-
Finishing (refer to “finishing” section).
WARNING
- Always light the pilot whether for the first time or if the gas supply has run out, with the glass door opened or removed.
- Provide adequate clearance for servicing and operating the appliance.
- Provide adequate ventilation.
- Never obstruct the front opening of the appliance.
- Objects placed in front of the appliance must be kept a minimum of 48” (121.9cm) from the front face of the appliance.
- Surfaces round and especially above the appliance can become hot. Avoid contact when appliance is perating.
- Fire risk. Explosion hazard.
- High pressure will damage valve. Disconnect gas supply piping before pressure testing gas line at test pressures above 1/2 PISG (35mb). Close the manual shut-off valve before pressure testing gas line at test pressures equal to or less than 1/2 PISG (35mb).
- Use only Wolf Steel approved optional accessories and replacement parts with this appliance using nonlisted accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could resultin a safetyhazard and will void the warranty andcertification.
- The appliance must not be operated at temperatures below freezing (32ºF/0ºC). Allow the appliance to warm to above freezing prior to operation.
THIS GAS APPLIANCE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example in the state of Massachusetts:
- This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts.
- The appliance damper must be removed or welded in the open position prior to installation of an appliance insert or gas log.
- The appliance off valve must be a “T” handle gas cock.
- The fl exible connector must not be longer than 36 inches (0.9m).
- A carbon monoxide detector is required in all rooms containing gas fi red appliances.
- The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.
The installation must conform with local codes or, in absence of local codes,
the National Gas and Propane Installation Code CSA B149.1 in Canada, or the
National Fuel Gas ode, ANSI Z223.1 / NFPA 54 in the United States. Suitable
for mobile home installation if installed in accordance with the current
standard CAN/CSA Z240MH Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
The appliance and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 psig (35 mb).
The appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas
supply piping system at test ressures equal to or less than 1/2 psig (35 mb).
When installed with a blower or fan, the junction box must be electrically
connected and grounded in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the
ANSI / NFPA 70 National Electric Code in the United States. In the case where
the blower is equipped with a power cord, it must be connected into a properly
grounded receptacle. The grounding prong must not be removed from the cord
plug.
The following does not apply to inserts; as long as the required clearance to
combustibles is maintained, the most desirable and beneficial location for an
appliance is in the center of a building, thereby allowing the most effi cient
use of the heat created. The location of windows, doors and, the traffic flow
in the room where the appliance is to be located should be considered. If
possible, you should choose a location where the vent will pass through the
house without cutting a floor or roof joist. If the appliance is installed
directly on carpeting, vinyl tile or other combustible material other than
wood fl ooring, the appliance shall be installed on a metal or wood panel
extending the full width and depth, unless otherwise tested.
We suggest that our gas hearth products be installed and serviced by
professionals who are certied in the U.S. by the National Fireplace Institute®
(NFI) as NFI Gas Specialists
1.4 rating plate information
This illustration is for reference only. Refer to the rating plate on the
appliance for accurate information.
note:
The rating plate must remain with the appliance at all times. It must not be
removed.
1.5 mobile home installation
This appliance must be installed in accordance with the manufacturer’s
instructions and the Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280, in he United States or the Mobile Home Standard, CAN/CSA
Z240 MH Series, in Canada. This appliance is only for use with the type(s) of
gas indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a
means to secure the appliance. Built in appliances are equipped with 1/4”
(6.4mm) diameter holes located in the front left and right corners of the
base. Use appropriate fasteners, inserted through the holes in the base to
secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For
mobile home installations, the appliance must be fastened in place. It is
recommended that the appliance be secured in all installations. Always turn
off the pilot and the fuel supply at the source, prior to moving the mobile
home. After moving the mobile home and prior to lighting the appliance, ensure
that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently
located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertibl for use with other gases, unless a
certified kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized
dealer/distributor.
note:
Conversion kits are not available for Vent Free appliances.
1.6 hardware list
Ref. # | Description | Quantity |
---|---|---|
BL36-1 | BL46 | |
1 | Self-drilling screw | 6 |
2 | Sheet metal screw | 18 |
3 | Sheet metal screw | 4 |
4 | Quad drive sheet metal screw | 4 |
5 | Sheet metal screw | 4 |
note:
Only fasteners supplied with the appliance will be illustrated.
1.7 optional heat management system
The Universal Heat Management system is an optional gravity vent kit that
allows you to manage the heat produced by the appliance at and around the
fireplace.
We recommend installing the Universal Heat Management system kit during the
installation of the appliance BEFORE the gas is installed.
For more information, contact your local authorized dealer.general information
*Finishing flange depth (the finishing flange defines the perimeter of the fireplace opening; framing or finishing materials must NEVER encroach inside the finishing flange).
Dimensions
2.1 BL36-1
*Finishing flange depth (the finishing flange defines the perimeter of the fireplace opening; framing or finishing materials must NEVER encroach inside the finishing flange).
2.2 BL46
*Finishing flange depth (the finishing flange defines the perimeter of the fireplace opening; framing or finishing materials must NEVER encroach inside the finishing flange).
Venting requirements
note:
The minimum clearances from the top of the horizontal vent pipe to combustible
materials may be reduced from 3” (76mm) to 1” (25mm) in those installations
with a minimum 38” (96.5cm) vertical vent rise made immediately off the
fireplace collar.
WARNING
- Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance.
- The vent system must be supported every 3’(0.9m) for both vertical and horizontal runs. Use support ring assembly W0100067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs. Spacers are attached to the inner pipe at predetermined intervals to maintain an even air gap to the outer pipe. This gap is required for safe operation. A spacer is required at the start, middle, and end of each elbow to ensure this gap is maintained. These spaces must not be removed.
This appliance uses a 4” (102mm) exhaust / 7” (178mm) air intake vent pipe
system. Refer to the section applicable to your installation.
For safe and proper operation of the appliance, follow the venting
instructions exactly. Deviation from the minimum vertical vent length can
create difficulty in burner start-up and/or carboning. Under extreme vent
confi gurations, allow several minutes (5-15) for the fl ame to stabilize
after ignition. Although not a requirement, it is recommended for vent lengths
that pass through unheated spaces (attics, garages, crawl spaces) be insulated
with the insulation wrapped in a protective sleeve to minimize condensation.
Provide a means for visually checking the vent connection to the appliance
after the appliance is installed. Use a fi restop, vent pipe shield or attic
insulation shield when penetrating interior walls, floor or ceiling.
The vent terminal may be painted with a high temperature paint to match
exterior colours. Use an outdoor paint suitable for 400°F (200°C). Application
and performance of paint is the consumer’s responsibility. Spot testing is
recommended.
note:
If for any reason the vent air intake system is disassembled, re-install per
the instructions provided for the initial installation.
This appliance must be installed with a continuous connection of exhaust and
air intake vent pipes. Utilizing alternate constructions such as a chimney as
part of the vent system is not permitted.
Use only Wolf Steel, Metal-Fab, BDM, Simpson Dura-Vent, or Selkirk Direct Temp
venting components. Minimum and maximum vent lengths, for both horizontal and
vertical installations, clearances from vent pipes to combustibles and air
terminal locations as set out in this manual apply to all vent systems and
must be adhered to. For Metal-Fab, BDM, Simpson Dura-Vent, or Selkirk Direct
Temp, follow the installation procedure provided with the venting components
or on the website for your venting supplier.
A starter adaptor must be used with the following vent systems and may be
purchased through Wolf Steel or from the corresponding supplier listed below:
Venting System| Manufacturer| Starter dapter Part Number|
Supplier| Website
---|---|---|---|---
SureSeal| MeIa.-Fab| »DNA| WO Steel| simv.mtlfab.com
Direct Vent Pro| Simpson DuraVent| W175-0053| Wolf Steel|
www.durayent.com
Pro-Form| BDM| DVR6-STA7| BDM| www.dalsinmfg.com
Direct Temp| Selkirk| 4DT-MN| Selkirk|
yrivw.selkirkcorp.com
Vents| Olympia Chimney and Venting| VDV-NA04-47F
and Venting| Oympia Chimney a|
siterw.olympiachimney.com
Connections made by means of an adaptor at the appliance, as well as the
connection at the vent terminal must be sealed. RTV sealant may be used on
both the inner exhaust and outer intake vent pipe joints of all other approved
vent systems, except for the exhaust vent pipe connection to the appliance
flue collar which must be sealed using the black high temperature sealant Mill
Pac.
For all vent systems is strongly recommend for all installations but required
when power venting the appliance, that the outer air intake joints are sealed
using either high temperature silicone (RTV) or a suitable aluminum tape that
covers each joint in the vent system entirely around its circumference. This
will ensure the best performance in every application and avoids performance
or condensation concerns that may occur in “tightly” constructed homes,
particularly those in cold climates.
This template must be used in conjunction with templates 7.1.1 or 7.1.2,
depending on termination shape (i.e. round, or round and square). See
appropriate templates folder.
When using Wolf Steel venting components, use only approved Wolf Steel rigid /
flexible components with the following termination kits: wall terminal kit
GD-222, GD-222R, ST47U or 1/12 to 7/12 pitch roof terminal kit GD-110, 8/12 to
12/12 roof terminal kit GD-111, fl at roof terminal kit GD-112 or periscope
kit GD-201 (for wall penetration below grade). With fl exible venting, in
conjunction with the various terminations, use either the 5 foot (1.5m) vent
kit GD-220 or the 10 foot (3.1m) vent kit GD-330. For stoves only: wall
terminal kit GD-175 (venting included). 415-3091 / C / 05.11.22 iate
templates folder.
For optimum flame appearance and appliance performance, keep the vent length
and number of elbows to a minimum.
The air terminal must remain unobstructed at all times. Examine the air
terminal at least once a year to verify that it is unobstructed and undamaged.
These vent kits allow for either horizontal or vertical venting of the
appliance. The maximum allowable horizontal run is 20 feet (6.1m). The maximum
allowable vertical vent length is 40 feet (12.2m). The maximum number of vent
connections is two horizontally or three vertically (excluding the appliance
and the air terminal connections) when using flexible venting.
Horizontal runs may have a 0” rise per foot or 0mm rise per meter however for
optimum performance it is recommended that all horizontal runs have a minimum
1/4” rise per foot or 21mm rise per meter using fl exible venting. For safe
and proper operation of the appliance, follow the venting instructions
exactly.
A terminal shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings. Local codes or regulations may require different clearances.
Do not allow the inside liner to bunch up on horizontal or vertical runs and
elbows. Keep it pulled tight. A 1¼” (31.8mm) air gap
all around between the inner liner and outer liner is requir
3.1 typical venting installation
special vent installation (periscope termination)
Use the periscope kit to locate the air termination above grade. The periscope
must be installed so that when final grading is completed, the bottom air slot
is located a minimum 12” (30.5cm) above grade. The maximum allowable vent
length is 10’ (3m) for a fireplace and 8’ (2m) for a stove.
3.2 minimum air terminal location clearances
QMIN = 3 feet (0.9m) | R MAX = 2 x QACTUAL | MAXR ≤ 15 feet (4.6m) |
---|---|---|
INSTALLATIONS | note: | |
--- | --- | --- |
CANADA | U.S.A. | Wall terminals are for illustration purposes only. Size and |
shapes may vary. Wall terminal
measurements taken from the exhaust outlet, not the mounting plate.
A| 12″ (30.5cm)| 12″ (30.5cm)| Clearance above grade. veranda porch, deck or
balcony.
B| 12″ (30.5cm) Δ| T (229mm) Δ| Clearance to windows or doors that open.
C| 12″ (30.5cm)| 12″ (30.5cm)| Clearance to permanently closed windows.
D| 18″ (45.7cm| 18″ (45.7cm)| Vertical clearance to ventilated soffits
located above the terminal within a horizontal distance of 2′ (0.6m) from the
center line of the terminal.
E| ‘ 2″ (30.5cm)| 12″ (30.5cm)| Clearance to unventilated soffit.
F| 0″ (0mm)| 0″ (0mm)| Clearance to an outside corner wall.
G| 0″ (0mm)| 0″ (Omm)| Clearance to an inSde non-combustible corner wall
or protruding non-combustible obstructions (chimney. etc.).
2′ (51 mm)| 2″ (51 mm)| Clearance to an inside combustible corner wall
or protruding combustible obstructions (vent chase. etc.).
H| 3′(0.9m)| 3fr(0.9m)| Clearance to each side of the center line extended
above the meter / regulator assembly to a maximum vertical distance of 15′
(4.6m).
I| 3′ (0.9m)| 3′ (0.9m)†| Clearance to a service regulator vent outlet.
J| 12″ (30.5cm)| 9″ (229mm)| Clearance to a non-mechanical air supply
inlet to the bilking or a combustion air inlet to any other appliance.
K| 6′ (1.8m)| 3′ (0.9m)†| Clearance to a mechanical air supply inlet.
L| 7′ (2.1m) ‡| 7′ (2.1m) | Clearance above a paved sidewalk or paved
driveway located on public property.
M| 12″ (30.5cm)††| 12″ (30.5cm)| Clearance under a veranda, porch, deck or
overhang.
N| 16″ (40.6cm)| 16″ (40.6cm)| Clearance above the roof.
0| 2′ (0.6m)†| 2′ (0.6m) †| Clearance from an adjacent wall including
neighbouring buildings.
P| 8′ (2.4m)| 8′ (2.4m)| Roof must be non-combustible without openings.
0| 3′ (0.9m)| 3′ (0.9m)| See chart for wider wall dimensions.
R| 6′ (1.8m)| 6′ (1.8m)| See chart for deeper wall dimensions. The terminal
shall not be installed on any wall that has an opening between the terminal
and the open side of the structure.
S| 12″ (30.5cm)| 12″ (30.5cm)| Clearance under a covered balcony
Δ The terminal shall not be located less than 6 feet under a window that opens on a horizontal plane in a structure with three walls and a roof.
- Recommended to prevent condensation on windows and thermal breakage
** It is recommended to use a heat shield and to maximize the distance to vinyl clad soffi ts.
* The periscope requires a minimum 18 inches clearance from an inside corner.
** This is a recommended distance. For additional requirements, check local codes.
† 3 feet above if within 10 feet horizontally.
‡ A vent shall not terminate where it may cause hazardous frost or ice accumulations on adjacent property surfaces.
†† Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the fl oor.
† Recommended to prevent recirculation of exhaust products. For additional requirements, check local codes.
†† Permitted only if the balcony is fully open on a minimum of one side.
note:
Clearances are to be in accordance with local installation codes and the
requirements of the gas supplier. In their absence, clearances are to be as
listed above and are based on national codes.
venting requirements
3.3 vent application flow chart
3.4 definitions
For the following symbols used in the venting calculations and examples are:
– greater than
– equal to or greater than
< – less than
< – equal to or less than
HT – total of both horizontal vent lengths (Hr) and offsets (Ho) in feet
HR – combined horizontal vent lengths in feet
HO – offset factor: .03 (total degrees of offset – 90°) in feet
HO – offset factor: .03 (total degrees of offset – 135°) in feet
VT – combined vertical vent lengths in feet
3.5 elbow vent length values
| Feet| Inches| Millimeters
---|---|---|---
1°| 0.03| 0.5| 12.7
15°| 0.45| 6.0| 152.4
30°| 0.9| 11.0| 279.4
45°| 1.35| 16.0| 406.4
90°*| 2.7| 32.0| 812.8
- The fi rst 90° offset has a zero value and is shown in the formula as – 90°
3.6 horizontal termination
For vent configurations requiring more than one 90° elbow, the following
formulas apply:
Formula 1: HT < VT
Formula 2: HT + VT < 40 feet (12.2m)
Example:
V1 = 3 ft (0.9m)
V2 = 8 ft (2.4m)
VT = V1 + V2 = 3 ft (0.9m) + 8 ft (2.4m) = 11 ft (3.4m)
H1 = 2.5 ft (0.8m)
H2 = 2 ft (0.6m)
HR = H1 + H2 = 2.5ft (0.8m) + 2 ft (0.6m) = 4.5 ft (1.4m)
HO = .03 (two 90° elbows – 90°) = .03 (180° – 90°) = 5.4 ft (1.7m)
HT = HR + HO = 4.5 ft (1.4m) + 5.4 ft (1.6m) = 9.9 ft (3m)
HT + VT = 9.9 ft (3m) + 11 ft (3.4m) = 20.9 ft (6.4m)
Formula 1: HT < VT
9.9 ft (3m) < 11 ft (3.4m)
Formula 2: HT + VT < 40 ft (12.2m)
20.9 ft (6.4m) < 40 ft (12.2m)
Since both formulas are met, this vent configuration is acceptable.
(HT) > (VT)
For vent configurations requiring more than one 90° elbow, the following
formulas apply:
Formula 1: HT < 4.2 VT
Formula 2: HT + VT < 24.75 feet (7.5m)
Example:
V1 = VT = 6 FT (1.8m)
H1 = 3 FT (0.9m)
H2 = 5 FT (1.5m)
HR = H1 + H2 = 3FT (0.9m) + 5FT (1.5m) = 8FT (2.4m) HO = .03 (two 90°
elbows – 90°) = .03 (180° – 90°) = 2.7FT (0.8m)
HT = HR + HO = 8FT (2.4m) + 2.7FT (0.8m) = 10.7FT (3.3m) HT + VT = 10.7FT
(3.3m) + 6FT (1.8m) = 16.7FT (5.1m)
Formula 1: HT < 4.2 VT 4.2 VT = 4.2FT (1.3m) x 6FT (1.8m) = 25.2FT (7.7m)
Formula 2: HT + VT < 24.75 FT (7.5m) 16.7 FT (5.1m) < 24.75 FT (7.5m)
Since both formulas are met, this vent configuration is acceptable.
Example:
V1 = 4 FT (1.2m)
V2 = 1.5 FT (0.5m)
VT = V1 + V2 = 4 FT (1.2m) + 1.5 FT (0.5m) = 5.5 FT (1.7m)
H1 = 2 FT (0.6m)
H2 = 1 FT (0.3m)
H3 = 1 FT (0.3m)
H4= 1.5 FT (0.5m)
HR = H1 + H2 + H3 + H4 = 2FT (0.6m) + 1FT (0.3m) + 1FT (0.3m) + 1.5FT
(0.5m) = 5.5 FT (1.7m)
HO = .03 (four 90° elbows – 90°) = .03 (360° – 90°) = 8.1 FT (2.5m)
HT = HR + HO = 5.5 FT (1.7m) + 8.1 FT (2.5m) = 13.6 FT (4.2m)
HT+ VT= 13.6 FT (4.2m) + 5.5 FT (1.7m) = 19.1 FT (5.8m)
Formula 1: HT < 4.2 VT 4.2 VT = 4.2 FT (1.3m) x 5.5 FT (1.7m) = 23.1 FT (7m)
13.6 FT (4.2m) < 23.1 FT (7m)
Formula 2: HT + VT < 24.75 FT (7.5m) 19.1 FT (5.8m) < 24.75 FT (7.5m)
Since both formulas are met, this vent configuration is acceptable.
3.7 vertical termination
(HT) < (VT)
For vent configurations requiring one or more 90° elbows the following formulas
apply:
Formula 1: HT < VT
Formula 2: HT + VT < 40 feet (12.2m)
Example:
V1 = 5 ft (1.5m)
V2 = 6 ft (1.8m)
V3 = 10 ft (3.1m)
VT = V1 + V2 + V3 = 5 ft (1.5m) + 6 ft (1.8m) + 10 ft (3.1m) = 21 ft (6.4m)
H1 = 8 ft (2.4m)
H2 = 2.5 ft (0.8m)
HR = H1 + H2 = 8 ft (2.4m) + 2.5 ft (0.8m) = 10.5 ft (3.2m)
HO = .03 (four 90° elbows – 90°)
= .03 (360° – 90°) = 8.1 ft (2.5m)
HT = HR + HO = 10.5 ft (3.2m) + 8.1 ft (2.5m) = 18.6 ft (5.7m)
HT + VT = 18.6 ft (5.7m) + 21 ft (6.4m) = 39.6 ft (12.1m)
Formula 1: HT < VT 18.6 ft (5.7m) < 21 ft (6.4m)
Formula 2: HT + VT < 40 ft (12.19m) 39.6 ft (12.1m) < 40 ft (12.2m)
Since both formulas are met, this vent configuration is acceptable.
(HT) > (VT)
For vent configurations requiring more than two 90° elbows the following
formulas apply:
Formula 1: HT < 3VT
Formula 2: HT + VT < 40 feet (12.2m)
Example:
V1 = 2 ft (0.6m)
V2 = 1 ft (0.3m)
V3 = 1.5 ft (0.5m)
VT = V1+V2+V3= 2 ft (0.6m) + 1 ft (0.3m) + 1.5 ft (0.5m) = 4.5 ft (1.4m)
H1 = 6 ft (1.8m)
H2 = 2 ft (0.6m)
HR = H1 + H2 = 6 ft (1.8m) + 2 ft (0.6m) = 8 ft (2.4m)
HO = .03 (four 90° elbows – 90°)
= .03 (360° – 90°) = 8.1 ft (2.5m)
HT = HR + HO = 8 ft (2.4m) + 8.1 ft (2.5m) = 16.1 ft (4.9m)
HT + VT = 16.1ft (4.9m) + 4.5 ft (1.4m) = 20.6 ft (6.3m)
Formula 1: HT < 3VT 3VT = 3 ft (0.9m) x 4.5 ft
(1.4m) = 13.5 ft (4.1m) 16.1 ft (4.9m) > 13.5 ft (4.1m)
Since this formula is not met, this vent configuration is unacceptable.
Formula 2: HT + VT < 40 ft (12.2m) 20.6 ft (6.3m) < 40 ft (12.2m)
Since only formula 2 is met, this vent configuration is unacceptable and a new
appliance location or vent configuration will need to be established to satisfy
both formulas.
3.8 vent shield installation (BL46 only)
A. Form vent shield to a 90° angle (as illustrated in installation step
above).
B. Install the vent shield by securing it to top of appliance using 2 screws
(supplied).
C. Adjust vent shield top to suit horizontal run.
Rough framing
note:
When using optional fi nishing accessories, the framing dimensions and fi
nishing materials may differ from what is outlined in the section below; refer
to the leafl et instructions supplied in the accessory kit for specifi c
framing and fi nishing specifi cations.
WARNING
- Risk of fi re!
- In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the appliance body, it is recommended that the walls of the appliance enclosure be “finished” (i.e. drywall / sheetrock), as you would fi nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.
- Do not notch the framing around the appliance stand offs. Failure to maintain air space clearance may cause over heating and fire. Prevent contact with sagging or loose insulation or framing and other combustible materials. Block opening into the chase to prevent entry of blown-in insulation. Make sure insulation and other materials are secured.
- When constructing the enclosure, allow for finishing material thickness to maintain clearances. Framing or fi nishing material closer than the minimums listed must be constructed entirely of non-combustible materials. Materials consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof are suitable. Materials that are reported as passing ASTM E136, standard test method for behaviour of materials in a vertical tube furnace at 1382ºF (750ºC) and UL763 shall be considered non-combustible materials.
- Minimum clearance to combusibles must be maintained or a serious fi re hazard could result.
- The appliance requires a minimum enclosure height. Measure from the appliance base.
- If steel stud framing kits with cement board are provided, or specifi ed in the installation instructions, they must be installed.
- If specifi ed in the installation instruction, finishing must be done using a non-combustible board, ceramic tile, marble, etc. Do NOT use wood or drywall. Any fi re rated drywall is not acceptable.
It is not necessary to install a hearth extension with this appliance.
4.1 minimum framing dimensions
note:
The minimum clearances from the top of the horizontal vent pipe to combustible
materials may be reduced from 3” (76mm) to 1” (25mm) in those installations
with a minimum 38” (96.5cm) vertical vent rise made immediately off the
appliance collar.
| BL36-1| BL46
---|---|---
A| 16” (40.6cm)| 18 9/16” (47.1cm)
B| 36 1/2” (92.7cm)| 47 3/8” (120.3cm
C| 35” (89cm)| 44” (111.7cm)
D| 6 5/16” (16cm)
E| 49 9/16” (125.8cm)| 62 1/4” (158.1cm)
F| 6” (15.2cm)
rough framing
Before framing your appliance, determine vent requirements before deciding the
final location of the appliance.
After rough framing, place the appliance in its final position.
| BL36-1| BL46
---|---|---
A| 16” (40.6cm)| 18 9/16” (47.1cm)
B| 36 1/2” (92.7cm)| 47 3/8” (120.3cm)
venting installation
WARNING
- Ensure to unpack all loose materials from inside the fi rebox prior to connecting the gas and electrical supply
- If your appliance is supplied with a remote, ensure the remote receiver is in the “OFF” position prior to connecting the gas and electrical supply to the appliance.
- For safe and proper operation of the appliance, follow the venting instructions exactly.
- The appliance exhaust flue collar must be sealed using Mill Pac. All exhaust and intake vent pipe joints must be sealed using red RTV high temp silicone sealant W573-0002) (not supplied) or black high temp Mill Pac (W573-0007) (not supplied).
- If using pipe clamps to connect rigid vent components, a minimum of 3 screws must also be used to ensure the connection cannot slip off.
- Do not clamp the flexible vent pipe.
- Risk of fi re, explosion, or asphyxiation. Improper support of the entire venting system may allow vent to sag and separate. Use vent run supports and connect vent sections per installation instructions.
- Risk of fi re, do not allow loose materials or insulation to touch the vent pipe. Remove insulation to allow for the installation of the attic shield and to maintain clearances to combustibles.
- Do not fill the space between the vent pipe and enclosure with any type of material. Do not pack insulation or combustibles between ceiling firestops. Always maintain specifi ed clearances around venting and firestop systems. Install wall shields and firestops as specifi ed. Failure to keep insulation or other materials away from vent pipe may cause fire.
- For gas stoves only: If the appliance is installed directly on carpeting, vinyl tile, or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth, unless otherwise tested.
For optimum performance, it is recommended that all horizontal runs have a minimum of 1/4″ (6mm) rise per foot using flexible venting. For safe and proper operation of the appliance, follow the venting instructions exactly.
5.1 horizontal installation
WARNING
- The fi restop assembly must be installed with the vent shield to the top.
- Terminals must not be recessed into a wall or siding more than the depth of the return flange of the mounting plate.
- The vent shield must be fixed in place by fastening the extended vent shield to the bend tabs using the supplied fasteners.
This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal location, cut and frame a hole in the exterior wall, as illustrated, to accommodate the firestop assembly. Dry fit the fi restop assembly before proceeding to ensure the brackets on the rear surface fit to the inside surface of the horizontal framing. The vent shield must be installed to the full depth of the combustible wall. The length of the vent shield may cut shorter for combustible walls that less than 8 1/2” (216mm) thick.
note:
Bend the tabs for reduced side clearances or move the shield for reduced top
clearances (dependent on specific appliance clearances). Do not fill the air
space between the stop spacer and the exterior wall with any type of
insulating material (i.e. spray foam).
A. Fold the vent shield up so that it is perpendicular to the spacer plate.
B. Bend the tabs located on either side of the vent shield so that they are
just shy of 90º to the spacer plate.
C. On both sides of the firestop, fasten the (W570-0018) screws through the
clearance holes in the bend tabs and threaded into the holes in the vent
shield.
D. Apply a bead of caulking around the outer edge of the firestop assembly.
E. Screw the fi restop onto the wall/framing, using 4 screws.
F. Once the vent pipe is installed in its final position, appl red RTV
silicone (W573-0002) (not supplied) between the pipe and the firestop.
note:
Where the venting passes horizontally through a wall, you MUST use a Wolf
Steel firestop for all rigid and flex vent systems. The gap between the
outside diameter of the vent and the firestop MUST be completely sealed with
high temperature RTV. When using fl ex venting, use firestop assembly
W010-3440 (not supplied).
When using rigid venting, use firestop assembly 4DHFSN (not supplied).
5.2 vertical installation
This application occurs when venting through a roof. Installation kits for
various roof pitches are available from your authorized dealer / distributor.
See the “accessories” section to order specific kits required.
A. Determine the air terminal location, cut and frame a square opening, as
illustrated, in the ceiling and the roof to provide the minimum 1″ (25mm)
clearance between the vent pipe and any combustible material. Try to center
the vent pipe location midway between two joists to prevent having to cut
them. Use a plumb bob to line up the center of the openings. A vent pipe
shield will prevent any materials such as insulation, from filling up the 1″
(25mm) air space around the pipe. Nail headers between the joist for extra
support.
B. Apply a bead of caulking (not supplied) to the framework or to the Wolf
Steel vent pipe shield plate or equivalent (in the case of a fi nished
ceiling), and secure over the pening in the ceiling. A firestop must be
placed on the bottom of each framed opening in a roof or ceiling that the
venting system passes through. Apply a bead of caulking all around and place a
firestop spacer over the vent shield to restrict cold air from being drawn
into the room or around the fireplace. Ensure that both spacer and shield
maintain the required clearance to combustibles. Once the vent pipe is
installed in its fi nal position, apply red RTV silicone (W573-0002) (not
supplied) between the pipe and the firestop assembly.
C. In the attic, slide the vent pipe collar
down to cover up the open end of the shield and tighten. This will prevent any
materials, such as insulation, from filling up the 1″ (25mm) air space around
the pipe.
note:
Where the venting passes vertically through a ceiling you use MUST use a Wolf
Steel firestop for all rigid and flex vent systems. The gap between the
outside diameter of the vent and the firestop MUST be completely sealed with
high temperature RTV.
For 4”/7” appliances:
When using flex venting, use fi restop assembly W500-0292 (not supplied).
When using rigid venting, use firestop assembly 4DFS (not supplied).
For 5”/8” appliances:
When using flex venting, use firestop assembly W500-0028 (not supplied).
When using rigid venting, use firestop assembly 5DFS (not supplied).
5.3 using either flexible or rigid vent components
WARNING
- Do not allow the inner flex pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight.
- Spacers are attached to the inner flex pipe at predetermined intervals to maintain an even air gap to the outer flex pipe. This gap is required for safe operation. A spacer is required at the start, middle, and end of each elbow to ensure this gap is maintained. These spacers must not be removed.
For safe and proper operation of the appliance, follow the venting instructionsexactly.
The vent system must be supported approximately every 3 feet (0.9m) for both vertical and horizontal runs. Use Wolf Steel Ltd. support ring assembly or equivalent noncombustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs. All inner flex pipe and outer flex pipe joints may be sealed using high temperature red RTV silicone W573-0002 (not supplied) or the high temperature sealant W5730007 Mill Pac (not supplied). However, the high temperature sealant W573-0007 Mill Pac (not supplied) must be used on the joint connecting the inner flex pipe and the exhaust flue collar. Use only approved flexible vent pipe kits marked:
“Wolf Steel Approved Venting” or “E2” as identified by the stamp only on the
flex pipes.
When installing using rigid vent components, follow the manufacturer’s
installation and vent sealing requirements.
5.4 using flexible vent components
5.4.1 horizontal air terminal installation
A. Stretch the inner flex pipe to the required length taking into account the
additional length needed for the finished wall surface. Apply a heavy bead of
the red RTV silicone
(W573-0002) (not supplied) to the inner sleeve of the air terminal. Slip the
vent pipe a minimum of 2” (50.8mm) over the inner sleeve of the air terminal
and secure with a minimum of 3 screws.
B Using the outer flex pipe, slide over the outer combustion air sleeve of
the air terminal and secure with a minimum of 3 screws. Seal using red RTV
silicone (W573-0002) (not supplied).
C. Insert the vent pipes through the firestop maintaining the required
clearance to combustibles. Holding the air terminal (lettering in an upright,
readable position), secure to the exterior wall and make weather tight by
sealing with caulking (not supplied).
D. If more vent pipe needs to be used to reach the fi replace, couple them
together, as illustrated. The vent system must be supported approximately
every 3 feet (0.9m) for both vertical and horizontal runs. Use non-combustible
strapping to maintain the minimum clearance to combustibles.
E. Stove Appliances Only: From inside the house, using Red RTV Silicone
(W573-0002) (not supplied), seal between the vent pipe and the firestop. Then
slide the black trim collar over the vent pipe up to the fi restop. The air terminal mounting plate may be recessed into the
exterior wall or siding no greater than the depth of its return flange.
5.4.2 vertical air terminal installation
**ARNING**
- Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar.
note:
Fastening hardware provided with appropriate roof terminal and liner kits.
A. Fasten the roof support to the roof using 6 screws. The roof support is optional. In this case, the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
B. Stretch the inner flex pipe to the required length. Slip the inner flex
pipe a minimum of 2” (51mm) over the inner pipe of the air terminal connector
and secure with a minimum of three screws, when 4/7, 5/8 and 3/5 venting is
used and a minimum of six screws when using 8/10 or 8/11 venting. Seal using a
heavy bead of red RTV silicone sealant (W573-0002) (not supplied).
C. Repeat using the outer flex pipe, using a heavy bead of red RTV silicone
sealant (W573-0002) (not supplied) and a minimum of three screws, when 4/7,
5/8 and 3/5 venting is used and a minimum of six screws when using 8/10 or
8/11 venting.
D. Thread the air terminal connector / vent pipe assembly down through the
roof. The air terminal must be positioned vertically and plumb. Attach the
air terminal connector to the roof support, ensuring that the top of the air
terminal is 16” (40.6cm) above the highest point that it penetrates the roof.
E. Remove nails from the shingles, above and to the sides of the air terminal
connector. Place the flashing over the air terminal connector leaving a min.
3/4” (19mm) of the air terminal connector showing above the top of the
flashing. Slide the flashing underneath the sides and upper edge of the
shingles. Ensure that the air terminal connector is properly centered within
the flashing, giving a 3/4” (19mm) margin all around. Fasten to the roof. Do
not nail through the lower portion of the fl ashing. Make weather-tight by
sealing with caulking. Where possible, cover the sides and top edges of the fl
ashing with roofi ng material.
F. Aligning the seams of the terminal and air terminal connector, place the
terminal over the air terminal connector making sure the vent pipe goes into
the hole in the terminal.
Secure with a minimum of three screws, when 4/7, 5/8 and 3/5 venting is used
and a minimum of six screws when using 8/10 or 8/11 venting.
G. Apply a heavy bead of weatherproof caulking 2” (51mm) above the fl ashing.
Install the storm collar around the air terminal and slide down to the
caulking. Tighten to ensure that a weather-tight seal between the air terminal
and the collar is achieved.
H. If more vent pipe needs to be used to reach the appliance, see “horizont
air terminal installation” section.
5.4.3 appliance vent connection
A. Install the inner flex pipe to the appliance. Secure with a minimum of
three screws when installing 3”/5”, 4”/7” or 5”/8” venting, or six scrwhen
installing 8”/10” or 8”/11” venting. Seal the joint and screw holes using Mill
Pac sealant (W573-0007) (not supplied). #8 X 1/2” Self Drilling Screws Mill
Pac Sealant
B. Install the outer flex pipe to the appliance. Secure with a minimum of
three screws when installing 3”/5”, 4”/7” or 5”/”8 venting, or six scrwhen
installing 8”/10” or 8”/11” venting. Seal the joints using high temperature
red RTV silicone (W573-0002) (not supplied). 1 1/2” (38.1mm)
5.5 using rigid vent components
5.5.1 horizontal air terminal installation
A. Move the appliance into position. Measure the vent length required between
terminal and ppliance taking into account the additional length needed for the
finished wall surface and any 2” (50.8mm) overlaps between venting components.
B. Apply a heavy bead of Mill Pac sealant (W573-0007) (not supplied) to the
outer edge of the inner collar of the appliance. Attach the first inner rigid
pipe component and secure using a minimum of three screws. Repeat using the
outer rigid pipe. Seal using Red RTV Silicone (W573-0002) (not supplied).
C. Insert the vent pipes through the firestop maintaining the
required clearance to combustibles. Apply a heavy bead of Red RTV Silicone
(W573-0002) (not supplied) to both the inner sleeve and outer sleeve of the
air terminal. Slide the terminal sleeves into the rigid pipes a minimum of 1
1/4”. Holding the air terminal (lettering in an upright, readable position),
secure to the exterior wall and make weather tight by sealing with caulking
(not supplied).
The air terminal mounting plate may be recessed into the exterior wall or
siding no greater than the depth of the return flange.
5.5.2 vertical air terminal installation
**WARNING**
- Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar.
note:
Fastening hardware provided with appropriate roof terminal and liner kits.
Before attaching elbows to the collars on the back of the appliance, 1 1/2”
(38.1mm) will need to be trimmed off the 4” (101.6mm) collar.
REAR VENT APPLICATIONS ONLY:
Attach 4” (101.6mm) and 7” (177.8mm) elbows to the appliance. Secure with 3
screws and seal the joints and screw heads using high temperature sealant.
Proceed to step A below.
TOP AND REAR VENT APPLICATIONS:
A. Move the appliance into position.
B. Fasten the roof support to the roof using the screws provided. The roof
support is optional. In this case the venting is to be adequately supported
using either an alternate method suitable to the authority having jurisdiction
or the optional roof support.
C. Apply high temperature sealant W573-0007 (not
supplied) to the outer edge of the inner sleeve of the air terminal. Slip the
inner coupler a minimum of 2” (51mm) over the sleeve and secure using 3
screws.
D. Apply high temperature sealant W573-0002 (not supplied) to the outer edge
of the of the outside sleeve of the air terminal connector. Slip the outer
coupler over the sleeve and secure as before. Trim the outer coupler even with
the inner coupler end.
E. Thread the air terminal connector / vent pipe assembly down through the
roof support and attach, ensuring that a minimum 16” (40.6cm)of air terminal
connector will penetrate the roof when fastened. If the attic space is tight,
we recommend threading the Wolf Steel vent pipe collar or equivalent loosely
onto the air terminal connector / vent pipe assembly as it is passed through
the attic. The air terminal connector must be positioned vertically and plumb.
F. Remove nails from the shingles, above and to the sides of the air terminal
connector. Place the flashing over the air terminal connector and slide it
underneath the sides and upper edge of the shingles. Ensure that the air
terminal connector is properly centered within the flashing, giving a 3/4”
(19.1mm) margin all around. Fasten to the roof. Do NOT nail through the lower
portion of the flashing. Make weather-tight by sealing with caulking. Where
possible, cover the sides and top edges of the fl ashing with roofing
material.
G. Apply a heavy bead of waterproof caulking 2” (51mm) above the flashing.
Install the storm collar around the air terminal and slide down to the
caulking. Tighten to ensure that a weather-tight seal between the air terminal
connector and the collar is achieved.
H. Continue adding rigid venting sections, sealing and securing as above.
Attach the inner collapsed telescopic sleeve to the last section of rigid
piping. Secure with screws and seal. Repeat using the outer telescopic sleeve.
I. Run a bead of high temperature sealant W573-0007 (not supplied) around the
outside of the inner elbow for rear vent applications or the inner collar for
top vent applications. Pull the telescopic sleeve a minimum of 2” (51mm) onto
the elbow. Secure with three screws. Repeat with the outer telescopic sleeve.
TOP VENT APPLICATIONS ONLY:
K. In the attic, slide the vent pipe collar down to cover up the open end
of the shield and tighten. This willprevent any materials, such as insulation,
from filling up the 1” (25mm) air space around the pipe.
5.5.3 restricting vertical vents
**WARNING**
- Turn off gas and electrical supply before servicing the appliance.
- Appliance may be hot, do not service until appliance is cool.
- For safe and proper operation of the appliance, follow the venting instruction exactly.
- To avoid danger of suffocation, keep the packaging bag away from babies and children. Do not use in cribs, beds, carriages or play pens. This bag is not a toy. Knot before throwing away.
Vertical installations may display a very active flame. If this appearance is
not desirable, the exhaust outlet may be restricted with a Wolf Steel approved
restrictor kit. This kit is not recommended for short vertical vent runs.
Depending on the model and/or year of your appliance, mounting holes may not
exist.
A. If mounting holes exist, remove the screws from the firebox top, align the
restrictor plate as illustrated and secure.
B. If mounting holes do not exist, align the restrictor plate as illustrated
and secure using the two #8×1/2 hex head sheet metal screws supplied.
C. Ensure the plate will pivot at the slot up into the exhaust outlet.
D. Depending on the amount of restriction desired, the restrictor plate can
be left flat for most restriction or bent up for varying degrees of
restriction.
5.6 vertical through existing chimney
WARNING
- Risk of fi re.
- Co-axial to co-linear venting confi gurations must only be used in a non-combustible chimney or enclosure. Installation in a combustible enclosure could result in a fire.
This appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum
flex vent system running the full length of a masonry chimney. The flex liners
accommodate any contours of a masonry chimney, however, it is necessary to
keep the flexible liners as straight as possible. The inlet air collar of the
termination cap must be connected to the air intake flex liner and the exhaust
collar must be connected to the exhaust fl exible liner.
Both Simpson Duravent and Selkirk co-linear to co-axial adaptors have been
approved on this appliance note: A vent adaptor will be required directly off
the appliance.
Follow vent manufacturer’s installation instructions.
Different manufacturer’s venting components must not be combined. Once the preferred manufacturer’s appliance adaptor has been attached, the remainder of the system must be that of the same manufacturer. The only exception to this rule is to use Wolf Steel’s approved 3” (76.2mm) fl ex liner and co-linear termination.
- Measured from appliance flue collar to termination flue collar
Electrical information
6.1 hard wiring connection
It is necessary to hard wire this appliance.
This appliance must be electrically connected and grounded in accordance with
local codes. In the absence of local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70-1996 National Electrical Code in
the United States.
6.2 receptacle wiring diagram
6.3
electronic wiring diagram
WARNING
- Do not use this appliance if any part has been under water. Call a qualified service technician immediately to have the appliance inspected for damage to the electrical circuit.
- Risk of electrical shock or explosion. Do not wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.
- All wiring should be done by a qualified electrician and shall be in compliance with local codes. In the absence of local codes, use the current CSA22.1 Canadian Electric Code in Canada or the current National Electric Code ANSI/NFPA NO. 70 in the United States.
- Always light the pilot whether for the first time or if the gas supply has run out, with the glass door opened or removed.
6.4 battery back-up installation
**WARNING**
- Ensure the gas and electrical power to the appliance is turned off.
- Appliance may be hot, do not service until the appliance has cooled.
note:
In the event of a power failure, your appliance can be operated using the
supplied battery back-up.
A. Remove the safety barrier to easily access the control compartment.
B. Turn off the gas and disconnect the electrical power supply from the
appliance.
C. Locate the battery housing inside the valve compartment.
D. Install 2 “D” alkaline batteries (not supplied) into the battery housing.
Ensure the positive and negative ends correspond with those identified on the
holder.
E. Turn the gas and electrical power back on to begin operating the
appliance.
F. Reinstall the safety barrier. The safety barrier must be installed at all
times during operation of the appliance.
6.5 wiring diagram
WARNING
- Do not wire 110 volts to the valve or wall switch.
note:
This appliance comes equipped with a battery back-up. If this back-up is used,
install 2 ‘D’ batteries (not supplied) into the holder. The backup is
controlled by a relay which will automatically switch to the back-up in the
event of a power failure. If the back-up is used, it must be connected to this
3 volt battery pack (supplied). Do not use any other type of battery pack.
Gas installation
WARNING
- Risk of fire, explosion, or asphyxiation. Ensure there are no ignition sources such as sparks or open flames.
- Support gas control when attaching gas supply pipe to prevent damaging gas line.
- Always light the pilot whether for the first time or if the gas supply has run out with the glass door opened or removed. Purging of the gas supply line should be performed by a qualified service technician. Ensure that a continuous gas flow is at the burner before closing the door. Ensure adequate ventilation. For gas and electrical locations, see “dimensions” section.
- All gas connections must be contained within the appliance when complete (gas fi replaces only).
- High pressure will damage valve. Disconnect gas supply piping before testing gas line at test pressures above 1/2 PSIG.
- Valve settings have been factory set, do not change.
Installation and servicing to be done by a qualifi ed installer.
- Move the appliance into position and secure.
- If equipped with a flex connector, the appliance is designed to accept a 1/2” (13mm) gas supply. Without the connector, it is designed to accept a 3/8” (9.5mm) gas supply. The appliance is equipped with a manual shut off valve to turn off the gas supply to the appliance.
- Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States.
- When flexing any gas line, support the gas valve so that the lines are not bent or kinked.
- The gas line flex-connector should be installed to provide sufficient movement for shifting the burner assembly on its side to aid with servicing components.
- Check for gas leaks by brushing on a soap and water solution. Do not use open flame.
After installing the electrical wiring and gas lines, ensure to test the appliance before finishing the framing and finishing the appliance.
Nailing tab installation
Use one screw to secure the short side of the nailing bracket to the
appliance.
note:
Adjust bracket to suit your desired finishing material.
note:
See “venting requirements”,, “venting installation”, “electrical information”
and “gas installation” sections prior to finish framing.
Operation
WARNING
- If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
- If applicable, always light the pilot whether for the first time or if the gas supply has run out with the glass door opened or removed.
When lit for the first time, the appliance will emit an odor for a few hours. This is a normal temporary condition caused by the “burn-in” of paints and lubricants used in the manufacturing process and will not occur again. After extended periods of non-operation, such as, following a vacation or warm weather season, the appliance may emit a slight odor for a few hours. This is caused by dust particules in the heat exchanger burning off. In both cases, open a window to suffi ciently ventilate the room.
FOR YOUR SAFETY READ BEFORE LIGHTING
- Do not turn on if children or other at risk individuals are near the appliance.
- This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
- Before operating, smell all around the appliance area for gas and next to the floor because some gas is heavier than air and will settle on the floor.
- Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control which has been underwater.
WHAT TO DO IF YOU SMELL GAS
• Turn off all gas to the appliance.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building
• Immediately call your gas supplier from a neighbour’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
LIGHTING INSTRUCTIONS
note:
This appliance is equipped with an ignition device which automatically lights
the pilot. Do not try to light the pilot by hand.
A. Stop! Read the above safety information on this label.
B. Remove batteries from the transmitter and set thermostat to lowest setting,
if equipped.
C. Turn off all electrical power to the appliance.
D. Open the glass door, if equipped.
E. Turn the manual shut-off valve clockwise to the “OFF” position. (Shut-off
valve is located on the flex connector).
F. Wait fi ve (5) minutes to clear out any gas. If you smell gas including
near the floor, STOP! Follow the instructions above in the “WHAT TO DO IF YOU
SMELL GAS” section. If you don’t smell gas; close the glass door and go to the
next step.
G. Turn the manual shut-off valve counter clockwise to the “ON” position.
H. Turn on all electrical power to the appliance and re-install the batteries
into the transmitter. Set thermostat to desired setting, if equipped.
I. Turn on the remote wall switch to the appliance.
J. If the appliance will not operate, follow instructions “TO TURN OFF GAS”
and call your service technician or gas supplier.
TO TURN OFF GAS
A. Set thermostat to lowest setting, if equipped.
B. Turn off the remote wall switch to the appliance.
C. Turn off all electric power to the appliance if service is to be performed.
D. Turn manual shutoff valve clockwise to the “OFF” positon. Do not force.
Finish framing
10.1 flush
WARNING
- Do not build into this area – it must be left clear to provide adequate clearance for the vent in this 14” (35.6cm) wide area centered along the front of the appliance. The appliance should be in its final location before framing.
|
BL36-1
|
BL46
---|---|---
B| 36 1/2″ (92.7cm)| 47 3/8″ (120.3cm)
G| 39 3/8″ (100cm)
A| 16″ (40.6cm)| I 18 9/16″ (47.1cm)
H| 56″ (142.2cm)
10.2 recessed
G | BL36-1 | BL46 |
---|---|---|
A | 39 3/8” (100cm) | |
B | 16” (40.6cm) | 18 9/16” (47.1cm) |
I | 36 1/2” (92.7cm) | 47 3/8” (120.3cm) |
J | 84” (213cm) | |
3 1/2” (89mm) |
- Allow for finished floor and hearth thickness when setting thesedimensions.
** 2” x 4” frame can be “backed” with 3/4” ply to support TV mounting hardware.
10.3 minimum clearance to combustible enclosures
note:
The vent shield is telescopic and must be adjusted to shield the full depth of
the combustible wall penetration.
- See “venting requirements” and “venting installation” sections.
** Clearances within the enclosure may be higher, see “minimum framing dimensions” section.
10.4 alcove enclosure
note:
Recesses or alcoves above the appliance must be made with non-combustible
material and regular minimum clearances, as defined for combustible materials,
must still be applied.
The recesses or alcoves can be made as deep as desired provided the minimum
clearances to combustibles are maintained.
The minimum enclosure volume must be increased by no less than the volume of
the recess. This adjustment can be made by increasing any or all of the
height, width and depth of the enclosure.
Finishing
WARNING
- Risk of fire!
- Never obstruct the front opening of the appliance.
- The front of the appliance must be finished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the pecified dimension, as illustrated.
- Do not strike, slam, or scratch. Do not operate appliance with glass removed, cracked, or scratched.
- Facing and/or finishing material must never overhang into the appliance opening.
- The glass door assembly is designed to pivot forward when relieving excess pressure that might occur. Finishing or other materials must not be located in the opening surrounding the door as this will interfere with the doors ability to relieve pressure.
11.1 control cover installation
Slide the back edge of the control cover down between the glass and the door frame. Insert downwards.
11.2 installing non-combustible board
WARNING
- Non-combustible facing material must not project more than 4” (102mm) from the face of the door (all three sides). If greater projections are desired, increase the clearance to the sides and top by 2” (51mm) for every additional 1” (25mm) of projection. If using an optional surround, the same rule applies, starting from the top of the surround.
Ensure clearances are maintained for surround removal, as it must lift off the appliance for maintenance.
| K
---|---
BL36-1| 37 1/16” (94.1cm)
BL46| 48” (121.9cm)
BL36-1| 31 9/16” (80.2cm)
BL46| 42 1/2” (107.9cm)
Joint Compound where required
Joint compounds such as Durabond 90 and tapes that are resilient to heat and
cracking should be used when taping and mudding seams.
Setting tiles and grouting
We recommend you use tiles with a dry butt joint to be installed using a two-
part mortar with an acrylic latex additive, such as Mapei Kerabond/Kerlastic,
to allow for slight movement in the normal operation of the appliance.
If grout is used between the tiles, a polymer-based grout, such as Mapei
Ultracolour plus, is recommended. Primer/Paint
For a painted surface, use a 100% acrylic latex primer and finish coat. Light
coloured paints may discolour.
11.3 minimum combustible mantel clearances
Combustible mantel clearance can vary according to the mantel depth. Use the
graph to help evaluate the clearance needed.
**WARNING**
-
Risk of fire! Reduced mantel clearances are ONLY acceptable for applications with UHM installed.
-
Mantel depth must be appropriately sized if placing any valuable items above the fireplace / mantel (see “clearances around appliance (TV and valuable objects)”).
11.4 clearances around appliance (TV and valuable objects)
- TV applications were tested with the minimum enclosure dimensions and the maximum recess permissible.
This data is provided in good faith and is not a guarantee for every application and television. Care and consideration should be taken when planning these installations to ensure the temperatures around the TV meet all manufacturer’s recommended operating temperatures. Increasing the height of the mantel and/or TV above the fireplace opening, the protrusion of mantel and the volume of the enclosure all have the effect of reducing the temperature above the fireplace. It is always recommended to use the optional heat management kit when considering mounting a television above the fireplace.
11.5 safety barrier & glass door installation / removal
WARNING
- Glass may be hot. Do not touch glass until cooled.
- If equipped with door latches that are part of a safety system, they must be properly engaged. Do not operate the appliance with latches disengaged.
- Facing and/or finishing materials must not interfere with air fl ow through air openings, louvre openings, operation of louvres, or doors/access for service. Observe all clearances when applying combustible materials.
- Before door is removed, turn the appliance off and wait until appliance is cool to the touch. Doors are heavy and fragile so handle with care.
A barrier designed to reduce the risk of burns from the hot viewing glass is
provided with the appliance and must be installed.
Before the glass door can be removed, the safety barrier must be removed. Lift
the safety barrier off the four shoulder screws and remove from the appliance.
Leave a hand on the glass door during entire door removal. The glass door is secured to the firebox with four (BL36-1) or six (BL46) spring latches. Pull the handles of the latches forward, then lift/lower the latches out from the door frame to release the door. Next, lift the door up until the bottom edge clears the bottom shoulder screws of the appliance. Carefully grip the top and bottom of the door lifting it off the appliance.
note:
These spring latches make up the spring relief system for the appliance.
Ensure the door opens freely and closes sealed.
note:
When mounting the door, ensure there is equal space on both the left and the
right side. This allows for easy installation of the front.
Reverse these steps to re-install the door and safety barrier. Ensure safety barrier is installed correctly.
11.6 glass media installation
WARNING
- Clean the glass media prior to installation. Before applying the cleaned glass, ensure that it is dry.
- Do not change or substitute the glass media material provided with this appliance. If replacing, use only the replacement glass media available from your local authorized dealer / distributor.
- Glass media over the burner must not be more than one layer high. More than one layer over the burner will cause flame lifting and sooting problems.
- Do not place any media (glass or vermiculite) in or around the pilot opening and/or on the burner ports. This will interfere with the pilot operation.
Evenly spread the glass media onto the media tray, covering the burner tube
and tray. Ensure no glass media falls into the pilot opening. If this happens,
insert a clean bag into your vacuum cleaner and vacuum out the glass media.
Replacement glass can be purchased from your local dealer / distributor.
note:
Do not use more media than what was certifi ed with the appliance.
Cleaning Glass Media
Glass media may have a fi ne oil residue that needs to be cleaned prior to
installation. Clean the glass with mild dish soap, drain, rinse thoroughly and
dry before placing over the burner.
note:
Care must be taken to ensure glass media are kept clear of the pilot area
on the media tray and are not interfering with the pilot operation.
11.7 optional blower installation
WARNING
- Ensure the appliance is completely cool before starting installation.
- To avoid danger of suffocation, keep the packaging bag away from babies and children. Do not use in cribs, beds, carriages or play pens. This bag is not a toy. Knot before throwing away.
A. Remove the safety barrier by lifting it up and off of the appliance.
B. Remove the door from the appliance by releasing the door latches.
C. It may be necessary to move the control module aside during blower
installation.
D. Attach the two 1/4” connectors (black and white) from the wire harness to
the thermodisc.
E. Attach the two 1/4” connectors (black and red) from the wire harness to
the blower.
F. Install the clear bumpers supplied onto the bottom of the blower to avoid
the blower rubbing against the floor of the appliance.
G. Pivot the blower into the bottom of the appliance, ensuring the gasket
remains in place between the blower and outer shell while sliding the blower
against the back side of outer shell into the blower mounting tab. Secure in
place using one screw, see Figures 1 & 2.
NOTE: WITH THE ZIP TIE SUPPLIED, ENSURE ALL WIRES REMAIN CLEAR OF THE
BLOWER.
note: The valve illustrated is for reference only.
H. Place the control module back into its original position. Ensure the
transformer is plugged into the rear outlet of the electrical box.
I. The variable speed switch (VSS) will need to be disassembled to secure to
the VSS bracket for installation.
Place the VSS through the mounting bracket using the lock washer to secure it
in place. Take the variable speed switch knob and install into position.
(Refer to Figure 3.)
J. To install the variable speed switch, the mounting bracket will first need
to be installed. Remove the two screws securing the piezo ignitor switch
bracket in place, install the VSS mounting bracket into position then
reinstall the two previously removed screws, refer to Figure 3. K. Plug the
connector from the variable speed switch to the matching connection on the
wire harness.
L. Ensure that the thermal disc is in contact with the firebox base and that
the wire harness is properly attached.
M. Plug the power cord from the blower into the electrical box.
NOTE: The blower is thermally activated, so when it is turned on, it will
automatically start approximately 15 minutes after lighting the appliance and
will run for approximately 30 minutes after the appliance has been turned off.
11.8 restricting vertical vents
Vertical installations may display a very active fl ame. If this appearance is
not desirable, the vent exit must be restricted using a restrictor vent kit.
Refer to the “replacement parts” section of the owner’s manual for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing
down the fl ame pattern and creating a more traditional gentle fl ame
appearance. Specifi c instructions are included with the kit.
11.9 venturi adjustment
note:
An air shutter access plate has been provided for initial flame appearance
setup. It becomes more difficult to adjust once the appliance has been
finished.
This appliance has an air shutter that has been factory set open according to
the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carbonization. Opening the air shutter will
cause a more blue flame, but can cause flame lifting from the burner ports.
The flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INSTALLER!
note:
It is important that the orifice is securely inserted into the
venturi. 11.10 check pressure readings
Inlet pressure can be checked by turning screw (A) counter clockwise 2 or 3
turns and then placing pressure gauge tubing over the test point. Gauge should
read as described on the chart below. Check pressure with main burner
operating on “HI”.
Outlet pressure can be checked the same as above using screw (B). Gauge should
read as described on the chart below. Check pressure with main burner
operating on “HI”.
After taking pressure readings, be sure to turn screws clockwise fi rmly to
reseal. Do not overtorque.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly has not been
painted. If overspray or painting of the pilot assembly has occurred remove
the paint from the pilot assembly, or replace. Fine emery cloth or a synthetic
scrub pad (such as Scotch-Brite™) can be used to remove the paint from the
pilot hood, electrode and flame sensor.
Pressure| Natural Gas (inches)| Natural Gas (millibars)| Propane (inches)|
Propane (millibars)
---|---|---|---|---
Inlet| *7″ (minimum 4.5″)| 17.4mb (minimum 11.2mb)| 13″ (minimum 11″)| 32.4mb
(minimum 27.4mb)
Outlet| 3.5″| 8.7mb| 10″| 24.9mb
*Maximum inlet pressure not to exceed 13”
11.11 flame characteristics
It’s important to periodically perform a visual check of the pilot and burner
flames. Compare them to the illustration provided. If any flames appear
abnormal, call a service person.
Maintenance
WARNING
- Turn off the gas and electrical power before servicing the appliance.
- Appliance may be hot. Do not service until appliance has cooled.
- Do not use abrasive cleaners on glass.
- Do not paint the pilot assembly.
This appliance and its venting system should be inspected before use and at
least annually by a qualified service person. The following suggested checks
should be performed by a qualifi ed technician. The appliance area must be
kept clear and free of combustible materials, gasoline, or other fl ammable
vapors and liquids. The flow of combustion and ventilation air must not be
obstructed.
note:
Caution: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.
- In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to expose both assemblies.
- Keep the control compartment, media, burner, air shutter opening and the area surrounding the appliance clean by vacuuming or brushing, at least once a year.
- Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.
- Check to see that the pilot flame is large enough to engulf the fl ame sensor and/or thermocouple / thermopile as well as it reaches the burner.
- If your appliance is equipped with a safety barrier, cleaning may be necessary due to excessive lint / dust from carpeting, pets, etc. simply vacuum using the brush attachment.
- If your appliance is equipped with relief doors, ensure the system performs effectively. Check that the gasket is not worn or damaged. Replace if necessary.
- Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carboning which can be distributed in the surrounding living area, inside the firebox and on exterior surfaces surrounding vent termination.
- Check to see that the main burner ignites completely on all ports when turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your local authorized dealer / distributor.
- Visually inspect the appliance for carbon build up. Using a small whisk or brush, brush off the carbon and vacuum up or sweep into garbage.
- This step is not applicable for Vent Free appliances: Check to see that the appliance is venting correctly. Ensure chimney system is safe and unobstructed. (If for any reason the vent air intakesystem is disassembled,re-install andre-seal per the instructionsprovided for the initial installation).
12.1 care of glass
WARNING
Do not clean glass when hot! Do not use abrasive cleaners to clean glass.
Buff lightly with a clean dry soft cloth to remove accumulated dust or fi
ngerprints. Clean both sides of the glass after the first 10 hours of
operation with an ammonia-free glass cleaner.
note:
Vinegar-based glass cleaners have demonstrated an ability to provide a clean,
streak free glass surface.
Thereafter, clean as required. If the glass is not kept clean permanent
discoloration and / or blemishes may result. Contact you local authorized
dealer / distributor for complete cleaning instructions.
Razor blades, steel wool, or other metallic objects must not be used on both
surfaces of the glass. Doing so can remove a thin layer of metal from the
razor blades, steel wool, or other metallic objects that may then be deposited
onto the coating. This can result in a discoloured stain or scratch-like mark.
More importantly, this can scratch the glass surface, thereby reducing its
strength.
Do not operate the appliance with broken glass, as leakage of flue gases may
result.
Contact your local authorized dealer / distributor for complete cleaning
instructions.
If the glass should ever crack or break while the fire is burning, do not open
the door until the fire is out. Do not operate the appliance until the glass
has been replaced. Contact you local authorized dealer / distributor for
replacement parts. DO NOT SUBSTITUTE MATERIALS.
This appliance is factory equipped with 4mm tempered glass. Use only
replacement parts as supplied by the appliance manufacturer. DO NOT SUBSTITUTE
MATERIALS.
12.2 annual maintenance
WARNING
- Annual maintenance should be performed by a qualified service technician
- The firebox becomes very hot during operation. Let the appliance cool completely or wear heat resistant gloves before conducting service.
- Never vacuum hot embers.
- Do not paint the pilot assembly
- This appliance will require maintenance which should be planned on an annual basis.
- Service should include cleaning, battery replacement, venting inspection and inspection of the burner, media, and firebox. Refer to the door removal section and remove the door as instructed.
- Carefully remove media if necessary (logs, glass, brick panels, etc.).
- Using a vacuum with soft brush attachment, gently remove any dirt, debris, or carbon build up from the logs, firebox, and burner. For glass media, follow the installation instructions for pre-cleaning.
- Gently remove any build-up on the pilot assembly including thermopile, thermocouple, flame sensor, and igniter (if equipped).
note:
Clean flame sensor using a fine emery cloth or a synthetic scrub pad (such as
Scotch-Brite™) to remove any oxides. Clean the pilot assembly using a vacuum
with a soft brush attachment. It is important that the pilot assembly is not
painted.
- Inspect all accessible gaskets and replace as required.
- If equipped with a blower, access the blower and clean using a soft brush and vacuum.
- Re-assemble the various components in reverse order.
- Inspect the relief system. The appliance relieves through the main glass door or through the flaps on the firebox top. Ensure they open freely, and close sealed.
- Check the gas control valve pilot and Hi / Lo knobs move freely, if equipped. Replace if any stiffness in movement is experienced.
- Check for gas leaks on all gas connections up and downstream from the gas valve including pilot tube connections.
12.3 glass / door replacement
WARNING
- Do not use substitute materials.
- Glass may be hot. Do not touch glass until cooled.
- Care must be taken when removing and disposing of any broken door glass or damaged components. Be sure to vacuum up any broken glass from inside appliance before operation.
- Do not strike, slam, or scratch. Do not operate appliance with glass removed, cracked, broken, or scratched.
Replacement glass/frame assembly shall be replaced as a complete unit as supplied by the appliance manufacturer.
replacement parts
WARNING
- Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury.
Contact your dealer for questions concerning prices and policies on
replacement parts. Normally, all parts can be ordered through your Authorized
dealer / distributor.
For warranty replacement parts, a photocopy of the original invoice will be
required to honour the claim.
When ordering replacement parts always give the following information:
- Model & Serial Number of appliance
- Installation date of appliance
- Part number
- Description of part
- Finish
Parts, part numbers, and availability are subject to change without notice.
Parts identified as stocked will be delivered within 2 to 5 business days for
most delivery destinations.
Parts not identified as stocked will be delivered within a 2 to 4 week period,
for most cases.
Parts identified as ‘SO’ are special order and can take up to 90 days for
delivery.
13.1 BL36-1 overview
Items may not appear exacl as illustrated
Ref. No | Part Number | Description | Stocked |
---|---|---|---|
1 | W565-0828-SER | Safety Screen | YES |
2 | W010-4159-SER | Safety Barrier Assembly | YES |
3 | W010-3631-SER | Door Assembly Kit | |
4 | W562-009 | Door Gasket Kit | YES |
5 | W570-0192 | Shoulder Screw (x2) | |
6 | W010-3554 | Door Lach (x4) | |
7 | RP4 | 4” Restrictor Plate | YES |
8 | W200-0675-SER | Control Cover | |
9 | W300-0231 | Topaz Glass Media | |
10 | W385-2010 | Napoleon Logo | YES |
11 | W060-0019 | Terminal Block | YES |
13.2 BL36-1 valve train assembly
Items may not appear exactly as illustrated.
Ref. No. | Part Number | Description | Stocked |
---|---|---|---|
11 | W432-0103 | Manifold flex pipe | |
12 | W456-0048 | Burner orifice #48 (NG) | Yes |
12 | W456-0056 | Burner orifice #56 (P) | Yes |
13 | W100-0227 | Burner assembly | |
14 | W290-0157 | Manifold gasket | |
15 | W335-0039 | Pilot hood | Yes |
16 | W455-0070 | Pilot orifice #62 (NG) | Yes |
16 | W455-0068 | Pilot orifice #35 (P) | Yes |
17 | W720-0062 | Pilot tube (w/ fittings) | Yes |
18 | W240-0016 | Electrode (w/ wire) | Yes |
19 | W245-0037 | Thermosensor | |
20 | W290-0364 | Valve train gasket | |
21 | W350-0342 | Battery housing | Yes |
22 | W190-0135 | Control board | Yes |
23 | W750-0463 | Wire harness | |
24 | W010-2863 | Pilot assembly (NG) | |
24 | W010-2900 | Pilot assembly (P) | |
25 | W750-0193 | Wire switch | |
26 | W175-0217 | Flex connector w/ valve | Yes |
27 | W725-0104 | Valve (NG) | Yes |
27 | W725-0105 | Valve (P) | Yes |
28 | W707-0002 | Transformer | |
29 | W190-0044 | Control relay |
13.3 BL46 overview
Items may not appear exactly as illustrated.
Ref. No. | Part Number | Description | Stocked |
---|---|---|---|
1 | W565-0274-SER | Safety screen | Yes |
2 | W010-4117-SER | Safety barrier assembly | Yes |
3 | W010-4100-SER | Door assembly | |
4 | W562-0060 | Door gasket kit | Yes |
5 | W570-0192 | Shoulder screw | |
6 | W200-0663-SER | Control cover | |
7 | RP4 | 4” Restrictor plate | Yes |
8 | W010-3554 | Door latch | |
9 | W300-0135 | T opaz glass media | Yes |
10 | W385-2010 | Napoleon logo | Yes |
13.4 BL46 valve train assembly
Items may not
appear exactly as illustrated.
Ref. No. | Part Number | Description | Stocked |
---|---|---|---|
11 | W432-0103 | Manifold flex pipe | |
12 | W456-0043 | Burner orifice #43 (NG) | Yes |
12 | W456-0053 | Burner Orifice #53 (P) | Yes |
13 | W290-0157 | Manifold gasket | |
14 | W100-0223-SER | Burner assembly | |
15 | W335-0039 | Pilot hood | Yes |
16 | W455-0070 | Pilot orifice #62 (NG) | Yes |
16 | W455-0068 | Pilot orifice #35 (P) | Yes |
17 | W720-0062 | Pilot tube (w/ fittings) | Yes |
18 | W240-0016 | Electrode (w/ wire) | Yes |
19 | W245-0037 | Thermosensor | |
20 | W290-0355 | Valve train gasket | |
21 | W350-0342 | Battery housing | Yes |
22 | W190-0135 | Control board | Yes |
23 | W750-0463 | Wire harness (control) | |
24 | W010-2863 | Pilot assembly (NG) | |
24 | W010-2900 | Pilot assembly (P) | |
25 | W750-0193 | Wire switch | |
26 | W175-0217 | Flex connector w/ valve | Yes |
26 | W725-0104 | Valve (NG) | Yes |
27 | W725-0105 | Valve(P) | Yes |
28 | W707-0002 | Power cord wire (18”) | |
29 | W190-0044 | Control relay |
troubleshooting
WARNING
- Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed.
- Turn off gas and electrical power before servicing the appliance.
- Appliance may be hot. Do not service until appliance has cooled.
- Do not use abrasive cleaners
symptom | problem | test solution |
---|
Main burner flame is a
blue, lazy, transparent
flame.
(This is not applicable
in outdoor appliances)| Blockage in vent.| – Remove blockage. In really cold
conditions, ice buildup may occur
on the terminal and should be removed as required. (To minimize this from
reoccuring, the vent lengths that pass through unheated spaces (attics,
garages, crawl spaces) should be wrapped with an insulated mylar sleeve).
Incorrect installation.| – Refer to “venting” section to ensure correct
installation.
Flames are consistently
too large or too small.
Carboning occurs.| Appliance is over-fired or underfired.| – Check pressure
readings: Inlet pressure can be checked by turning screw (A) counter-clockwise
2 or 3 turns and then placing
pressure gauge tubing over the test point. Gauge should
read as described on the chart below. Check that main burner is operating on
‘HI’. Outlet pressure can be checked the same as bove using screw (B). Gauge
should read as described on the chart below. Check that main burner is
operating on ‘HI’. After taking pressure
readings, be sure to turn screws clockwise firmly to reseal. DO NOT OVER
TORQUE. Leak test with a soap and water solution.| Pressure| Natural Gas
(inches)| Natural Gas (millibars)| Propane (inches)| Propane (millibars)
---|---|---|---|---
Inlet| *7″ (minimum 4.5″)| 17.4mb (minimum 11.2mb)| 13″ (minimum 11″)| 32.4mb
(minimum 27.4mb)
Outlet| 3.5″| 8.7mb| 10″| 24.9mb
*Maximum inlet pressure not to exceed 13” w.c.
Air shutter improperly adjusted.| – Return air shutter to specifi ed opening,
see “venturi adjustments” section in the installation manual.
Carbon is being
deposited on glass, logs, rocks, media, or combustion chamber surfaces.| Air
shutter is blocked.| – Ensure air shutter opening is free of lint or other
obstructions.
Flame is impinging on the glass, logs, rocks, media or combustion
chamber.| – Ensure the media is positioned correctly in the appliance.
– Open air shutter to increase the primary air.
– Check the input rate: check the manifold pressure and orifi ce size as
specified by the rating plate.
– Ensure door gaskets are not broken or missing and the seal is tight.
– Ensure vent liners are free of holes and well sealed at all joints.
– Check that minimum rise per foot (meters) has been adhered to for any
horizontal venting.
White / grey film forms.| Sulphur from fuel is being deposited on glass, logs,
or combustion chamber
surfaces.| – Clean the glass with a recommended gas fi replace glass cleaner.
DO NOT CLEAN GLASS WHEN HOT.
– If deposits are not cleaned off regularly, the glass may become permanently
marked.
Exhaust fumes smelled in room, headaches.| Appliance is spilling.
(This is not applicable in outdoor appliances).| – Check door seal.
– Check for exhaust damage.
– Check that venting is installed correctly.
– Room is in negative pressure; increase fresh air supply.
Pilot will not light. Makes
noise with no spark at
pilot burner.| Wiring: short, loose, or damaged connections (poor flame
rectification).| – Verify the thermocouple/sensor is clean and the wiring is
undamaged.
– Verify the interrupter block is not damaged or too tight. Verify connections
from pilot assembly are tight; also verify the connections are not grounding
out to any metal. (Remember, the flame carries the rectifi cation current, not
the gas. If flame lifts from pilot hood, the circuit is broken. A wrong
orifice or too high of an inlet pressure can cause the pilot flame to lift)*.
The sensor rod may need cleaning.
No signal from remote with no
pilot ignition.| – Reprogram receiver code.
– Replace receiver.
Poor grounding.| – Verify the valve / pilot assembly are properly grounded
Improper switch wiring.| – Troubleshoot the system with the simplest on/off
switch.
Dirty, painted, or damaged pilot and/or dirty sensor rod.| – Clean sensor rod
with a green Scotch-Brite™ pad to remove any contamination that may have
accumulated. Verify continuity with multimeter with ohms set at the lowest
range.
Pilot sparks but will
not light.| Gas supply.| – Verify that the incoming gas line ball valve is
“open”.
– Verify that the inlet pressure reading is within acceptable limits, inlet
pressures must not exceed 13” W.C. (32.4mb).
Out of propane gas.| – Fill the tank.
Pilot supply line may contain air.| – Repeat ignition process several times or
purge the pilot supply line.
Incorrect wiring / grounding.| – Ensure correct polarity of wiring of
thermocouple (if equipped).
– Verify pilot assembly / valve are properly grounded.
Receiver (if equipped).| – Reset program: hold reset button on receiver and
wait for 2 beeps. Release after second beep. Press small fl ame button on
remote within 20 seconds, you will hear an additional beep (this signals a
successful reset).
– Replace receiver.
Valve.| – Check valve and replace if necessary (Do not to overtighten
thermocouple).
Burner continues to spark and pilot lights but main burner
does not light.| Short or loose connection in
sensor rod.| – Verify all connections. Verify the connections from the pilot
assembly are tight. Also, verify these connections are not grounding out to
any metal.
Dirty, painted, or damaged
pilot assembly components.| – Clean using a green Scotch-Brite™ pad to remove
any contamination that may have accumulated on the sensor rod, pilot hood,
ignitor, or fl ame sensor. Verify continuity with multimeter with ohms set at
the lowest range.
Remote wall switch is in “off” position; burner comes on.
Remote and / or
receiver is not
functioning properly.| Wall switch mounted upside down.| – Reverse.
Remote wall switch and/or wire is grounding.| – Replace.
– Check for ground (short); repair ground or replace wire.
Faulty wire| – Replace.
Remote controls lights but no spark or flame. (Remote is locked out).| – Reset
by turning power source off then on.
note:
If back up batteries are installed, they must also be removed to re-program
Receiver or remote has low battery.
Appliance functions but does not respond to receiver / remote| – Replace
batteries.
– Ensure appliance is being operated by the same device that turned it on.
Remote controls function if appliance was turned on by remote. Receiver
controls function if appliance was turned on by receiver.
Error with synchronizing.
Remote too far away from receiver.| – Reset receiver and remote.
– Refer to “wiring diagram” section.
Wire connector pins are bent.
Valve wiring is damaged.| – Straighten pins.
– Replace valve.
Lights or blower
won’t function (if
equipped).| Control module switch in wrong position.| – Verify ON/OFF switch
is in the “I” position which denotes on.
COM switch is unplugged.| – Verify “COM” switch is plugged into the front of
the control module.
Flames are very
aggressive.| Door is ajar.| – Ensure door is secured properly.
Venting action is too great.| – Check to ensure venting is properly sealed or
restrict vent exit with restrictor plate. (Not available in all appliances).
Appliance won’t perform any
functions.| No power to the system.| – Check breaker to verify it’s in the
“on” position.
Receiver switch in wrong position (if equipped).| – Verify that the 3 position
switch on the receiver is in the remote position (middle).
Transmitter isn’t operational.| – Check battery power and battery orientation.
warranty
Napoleon products are manufactured under the strict Standard of the world
recognized ISO 9001 : 2015 Quality Management System.
Napoleon products are designed with superior components and materials
assembled by trained craftsmen who take great pride in their work. The burner
and valve assembly are leak and test-fi red at a quality test station. The
complete appliance is again thoroughly inspected by a qualifi ed technician
before packaging to ensure that you, the customer, receive the quality product
that you expect from Napoleon.
Napoleon Gas Appliance President’s Lifetime Limited Warranty
The following materials and workmanship in your new Napoleon gas appliance are
warranted against defects for as long as you own the appliance. This covers:
combustion chamber, heat exchanger, stainless / steel burner, Phazer™ logs and
embers, rocks, ceramic glass (thermal breakage only), gold plated parts
against tarnishing, porcelainized enameled components and aluminum extrusion
trims.
Electrical (110V and millivolt) components and wearable parts are covered and
Napoleon will provide replacement parts free of charge during the fi rst year
of the limited warranty. This covers: blowers, gas valves, thermal switches,
switches, wiring, remote controls, ignitors, gaskets and pilot assemblies.
Labour related to warranty repair is covered free of charge during the fi rst
year (labour warranty is not applicable for the Gas Log Sets). Repair work,
however, requires the prior approval of an authorized company offi cial.
Labour costs to the account of Napoleon are based on a predetermined rate
schedule and any repair work must be done through an authorized Napoleon
dealer.
- Construction of models vary. Warranty applies only to components included with your specifi c appliance.
Conditions and Limitations
Napoleon warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not necessary. Simply provide your proof of purchase along with the model and serial number to make a warranty claim.
Napoleon reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim. Provided that the purchase was made through an authorized Napoleon dealer your appliance is subject to the following conditions and limitations:
Warranty coverage begins on the date of original installation. This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives. The gas appliance must be installed by a licensed, authorized service technician or contractor qualifi ed and authorized installer, service agency or supplier. Installation must be done in
accordance with the installation instructions included with the product and all local and national building and fi re codes. This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect, and parts installed from other manufacturers will nullify this warranty. This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of Phazer™ logs and embers. This warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions. After the fi rst year, with respect to this President’s Lifetime Limited Warranty, Napoleon may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
After the fi rst year, Napoleon will not be responsible for installation, labour, or any other expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty. Notwithstanding any provisions contained in the President’s Lifetime Limited Warranty, Napoleon’s responsibility under this warranty is defi ned as above and it shall not in any event extend to any incidental, consequential or indirect damages. This warranty defi nes the obligations and liability of Napoleon with respect to the Napoleon gas appliance and any other warranties expressed or implied with respect to this product, its components or accessories are excluded. Napoleon neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Napoleon will not be responsible for: overfiring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc. Any damages to the appliance, combustion chamber, heat exchanger, plated trim or other components due to water, weather damage, long periods of dampness, condensation, damaging chemicals or leaners will not be the responsibility of Napoleon.
During the fi rst 10 years Napoleon will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, Napoleon will provide replacement parts at 50% of the current retail price.
The manufacturer may require that defective parts or products be returned or that digital pictures be provided to support the claim. Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will repair or replace such defect. Before shipping your appliance or defective components, your dealer must obtain an authorization number. Any merchandise shipped without authorization will be refused and returned to sender. Shipping costs are not covered under this warranty. Additional service fees may apply if you are seeking warranty service from a dealer. Warranty labour allowance is only for the replacement of the warranted part. Travel, diagnostic tests, shipping and other related charges are not covered by this warranty.
All specifications and designed are subject to change without prior notice due to on-going product improvements. Napoleon is a registered trademark of Wolf Steel Ltd.
NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS
7200, Route Transcanadienne, Montréal, Québec H4T 1A3
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8
214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
103 Miller Drive, Crittenden, Kentucky, USA 41030
De Riemsdijk 22, 4004 LC Tiel, The Netherlands
Phone: 1-866-820-8686
napoleon.com
References
- Napoleon® Canada | Barbecue Grills, Fireplaces, Heating & Cooling
- Manufacturer & Distributor of Chimney & Venting | Bernard Dalsin Manufacturing
- Duravent
- Metal-Fab Residential Commercial Venting Products
- Napoleon® Canada | Barbecue Grills, Fireplaces, Heating & Cooling
- National Fireplace Institute (NFI) – The national certification division of the Hearth, Patio & Barbecue Education Foundation (HPBEF)
- Olympia Chimney – Distributed through Copperfield
- P65Warnings.ca.gov
- Selkirk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>