What is the TS710 Timer

The TS710 is used to switch your gas boiler either directly or via a motorized valve. The TS710 has made setting your on/off times easier than ever before.

Setting time and Date

  • Press and hold the OK button for 3 seconds, and the screen will change to show the current year.
  • Adjust using or setting the correct year. Press OK to accept. Repeat step b to set month and time settings.

Timer Schedule Setup

  • The Advanced Programmable Timer Function allows setting a timer-con-trolled program for automatically scheduled event changes.
  • The example below for 5/2 day setup
  • a. Press the button to access schedule setup.
  • b. Set CH flashes, and press OK to confirm.
  • c. Mo. Tu. We. Th. Fr. will flash on the display.
  • d. You can select weekdays (Mo. Tu. We. Th. Fr.) or weekends (Sa. Su.) with buttons.
  • e. Press the OK button to confirm the days selected (e.g. Mon-Fri) The chosen day and 1st ON time are displayed.
  • f. Use or select ON hour, and press OK to confirm.
  • g. Use or select ON minute, and press OK to confirm.
  • h. Now the display changes to show the “OFF” time
  • I. Use or select OFF hour, and press OK to confirm.
  • j. Use or select OFF minute, and press OK to confirm.
  • k. Repeat steps f. to j. above to set 2nd ON, 2nd OFF, 3rd ON & 3rd OFF events. Note: the number of events is changed in the user settings menu P2 (see table)
  • l. After the last event time is set, if you were setting Mo. to Fr. the display will display Sa. Su.
  • m. Repeat steps f. to k. to set Sa. Su times.
  • n. After accepting Sa. Su. final event your TS710 will return to normal operation.
  • If your TS710 is set for a 7-day operation, the option will be given to select each day separately.
  • In 24-hour mode, the option will only be given to select Mo. to Su. together.
  • To change this setting. See user settings P1 in the User Settings table.
  • Where the TS710 is set for 3 periods, options will be given to select the period 3 times.
  • In 1 Period mode, the option will be only given for one ON/OFF time. See User Settings P2.

Display and Navigation Details

Display & Navigations

Danfoss-TS710-Single-Channel-Timer-
fig-2

  • To access additional features press and hold the button for 3 seconds.
  • To reset the timer, press and hold the PR and OK buttons for 10 seconds.
  • The reset is complete after ConFtext appears on the display.
  • (Note: This does not reset service due to timer or date and time settings.)
Holiday Mode
  • Holiday Mode temporarily disables the timing functions when away or out for a period of time.
  • a. Press the PR button for 3 seconds to enter Holiday mode. icon will be shown on the display.
  • b. Press the PR button again to resume normal timings.
Channel Override
  • You can override the timing between AUTO, AUTO+1HR, ON, and OFF.
  • a. Press the PR button. CH will flash and current timer function, e.g. CH – AUTO.
  • b. With channel flashing press buttons to change between AUTO, AUTO+1HR, ON, and OFF
  • c. AUTO = The system will follow programmed schedule settings.
  • d. ON = The system will remain constant ON until the user changes the setting.
  • e. OFF = the system will remain constant OFF until the user changes the setting.
  • f. a. AUTO+1HR = To boost the system for 1 hour press and hold the button for 3 seconds.
  • f. b. With this selected, the system will remain ON for an extra hour.
  • If it is selected while the program is OFF, the system will switch ON immediately for 1 hour and then resume programmed times(AUTO mode) again.

User Settings

  • a. Press the button for 3 seconds to enter the parameter setting mode. set the parameter range via or and press OK.
  • b. To exit parameter setup press, or after 20 seconds if no button is pressed unit will return to the main screen.
No. Parameter settings Settings range Default
P1 Working mode 01: Schedule timer 7 day 02: Schedule timer 5/2 day 03:
Schedule timer 24hr 02
P2 Schedule periods 01: 1 period (2 events)

02: 2 periods (4 events)

03: 3 periods (6 events)

| 02
P4| Timer display| 01: 24hr

02: 12hr

| 01
P5| Auto daylight saving| 01: On

02: Off

| 01
P7| Service due setup| Installer setting only|

  • Danfoss A/S
  • Heating Segment
  • danfoss.com
  • +45 7488 2222
  • E-mail: heating@danfoss.com
  • Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material.
  • Danfoss reserves the right to alter its products without notice.
  • This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
  • All trademarks in this material are the property of the respective companies.
  • Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
  • www.danfoss.com

Documents / Resources

| Danfoss TS710 Single Channel Timer [pdf] User Guide
TS710 Single Channel Timer, TS710, Single Channel Timer, Channel Timer, Timer
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals