Dwyer L6EPB-B-S-3-O FLOTECT Liquid Level Switch Installation Guide
- June 10, 2024
- Dwyer
Table of Contents
FLOTECT® LIQUID LEVEL SWITCHES
Easy In-wall or External Installation, Up to
2000 psig (138 bar), Compact Size
SERIES L6
L6EPB-B-S-3-O FLOTECT Liquid Level Switch
The Series L6 Flotect ® Liquid Level Switches are rugged and reliable float switches which operates automatically to indicate tank level. It is offered with a 303 SS or brass body with spherical or cylindrical float options.
BENEFITS/FEATURES
- Trouble-free service due to compact design
- Simple and dependable operation with no mechanical linkage
- Leak-proof lower body machined from bar stock
- Flexible application use with side wall or direct tee mounting options available to act as an external float chamber
- Ideal for demanding outdoor applications with weatherproof and explosion-proof body
- Save on maintenance costs with electrical assembly that can be easily replaced without removing the unit from the installation so that the process does not have to be shut down
- High accuracy with sensitivity to level changes of less than 1/2˝ (12 mm)
APPLICATIONS
- Direct pump control for maintaining level
- Automatic tank dump operations
- Level control
- Valve control
- Level alarm in sumps, scrubber systems, hydro-pneumatic tanks, boilers, and water/wastewater treatment processes
OPTIONS
To order add suffix: | Description |
---|
-AT
-CSA
-IEC
-MT
-MV| ATEX compliant construction includes, weatherproof and explosion-proof, junction box
CSA and UL approved construction, includes weatherproof and explosion-proof
junction box
IECEx certified construction, weatherproof and explosionproof, junction box
High temperature rated 400°F (204°C) (see electrical rating in specifications,
no listings or approvals, only available on
models with stainless steel floats)
Gold plated contacts for dry circuits (see electrical rating in
specifications)
Note: M25 is not available with the CSA housing.
DPDT Contacts
Note: To order, change seventh character in model number to “D”.
Example: L6EPB-B-D-3-O
Options Not Shown: 1-1/2˝ and 2˝ (38.10 and 50.80 mm) male NPT or 1-1/2˝ and
2˝ (38.10 and 50.80 mm) male BSPT process connection, 2˝ female NPT or 2˝
female BSPT.
SPECIFICATIONS
Service: Liquids compatible with wetted materials.
Wetted Materials: Float: Solid polypropylene or 304 SS; Lower body: Brass
or 303 SS; Magnet: Ceramic; External float chamber (tee): Matches lower body
choice of brass or 303 SS; Other: Lever arm, spring, pin, etc.: 301 SS.
Temperature Limit: -4 to 220°F (-20 to 105°C) Standard, MT high
temperature option 400°F (205°C)(MT not UL, CSA, ATEX, IECEx and KC). ATEX
compliant AT, IECEx IEC and KC option ambient temperature -4 to 167°F (-20 to
75°C) process temperature: -4 to 220°F (-20 to 105°C).
Pressure Limits: See model chart.
Enclosure Rating: Weatherproof and explosion-proof. Listed with UL and
CSA for Class I, Groups A, B, C and D; Class II, Groups E, F, and G. (Group A
on SS body models only).
ATEX 2813 II 2 G Ex db IIC T6 Gb Process Temp≤75°C.
EU-Type Certificate No.: KEMA 04ATEX2128.
ATEX Standards: EN 60079-0:2012+A11:2013; EN 60079-1:2014.
IECEx Certified: For Ex d IIC T6 Gb Process Temp≤ 75°C.
IECEx Certificate of Conformity: IECEx DEK II.0039.
IECEx Standards: IEC 60079-0:2011; IEC 60079-1:2014.
Korean Certified (KC) for Ex db IIC T6 Gb Process Temp≤75°C.
KTL Certificate Number: 12-KB4BO-0091.
Switch Type: SPDT snap switch standard, DPDT snap switch optional.
Electrical Rating: UL models: 5 A @ 125/250 VAC (V~). CSA, ATEX and
IECEx models: 5 A @ 125/250 VAC (V~); 5 A res., 3 A ind. @ 30 VDC (V ). MV
option: .1 A @ 125 VAC (V~). MT option: 5 A @125/250 VAC (V~). [MT option not
UL, CSA, ATEX or IECEx].
Electrical Connections: UL models: 12-KB4BO-0091 18 AWG, 18˝ (457.20 mm)
long. ATEX/CSA/IECEx models: Terminal block.
Upper Body: Brass or 303 SS.
Conduit Connection: 3/4˝ (19.05 mm) male NPT standard, 3/4˝ (19.05)
female NPT or M25 with BSPT option on junction box models.
Process Connection: 1˝ (25.40 mm) male NPT or 1˝ (25.40 mm) male BSPT on
models without external float chamber, 1˝ (25.40 mm) female NPT or 1˝ (25.40
mm) female BSPT on models with external float chamber.
Mounting Orientation: Horizontal with index arrow pointing down.
Specific Gravity: See chart.
Weight: Approximately 1 lb (.5 kg) without external float chamber, 1.75
lb (.8 kg) with external float chamber.
Compliance: ATEX, CE, CSA, IECEx, KTL, UL.
MODEL CHART
Model| Body| Installation| Float Material| Process
Connection| Max. Pressure psig (bar)| Min. S.G.
---|---|---|---|---|---|---
L6EPB-B-S-3-O
L6EPB-B-S-3-A
L6EPB-B-S-3-C
L6EPB-B-S-3-B
L6EPB-B-S-3-H
L6EPS-S-S-3-O
L6EPS-S-S-3-A
L6EPS-S-S-3-C
L6EPS-S-S-3-S
L6EPS-S-S-3-L| Brass
Brass
Brass
Brass
Brass
303 SS
303 SS
303 SS
303 SS
303 SS| Side wall mounting
Side wall mounting
Side wall mounting
Brass external float chamber (tee)
Brass external float chamber (tee)
Side wall mounting
Side wall mounting
Side wall mounting
304 SS external float chamber (tee)
304 SS external float chamber (tee)| Polypropylene spherical
304 SS cylindrical
304 SS spherical
Polypropylene spherical
304 SS spherical
Polypropylene spherical
304 SS cylindrical
304 SS spherical
Polypropylene spherical
304 SS spherical| NPT
NPT
NPT
NPT
NPT
NPT
NPT
NPT| 1000 (69)
200 (13.8)
350 (24.1)
250 (17.2)
250 (17.2)
2000 (138)
200 (13.8)
350 (24.1)
2000 (138)
350 (24.1)| 0.9
0.5
0.7
0.9
0.7
0.9
0.5
0.7
0.9
0.7
USA: California Proposition 65
WARNING: This product can expose you to chemicals including Lead, which
is known to the State of California to cause cancer and birth defects or other
reproductive harm. For more information go to
www.P65Warnings.ca.gov.
DWYER INSTRUMENTS, LLC
dwyer-inst.com
Documents / Resources
|
Dwyer L6EPB-B-S-3-O FLOTECT Liquid Level
Switch
[pdf] Installation Guide
L6EPB-B-S-3-O FLOTECT Liquid Level Switch, L6EPB-B-S-3-O, FLOTECT Liquid Level
Switch, Liquid Level Switch, Level Switch
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>