Dwyer E-111-A-QS Pressure Transmitters User Guide

June 1, 2024
Dwyer

Dwyer E-111-A-QS Pressure Transmitters

Dwyer-E-111-A-QS-Pressure-Transmitters-prodcut

Product Specifications

  • Model: Series 626 & 628 Pressure Transmitters
  • Output : Current output (mA) and Voltage output (V)
  • Power Supply: 13-30 VDC
  • Mounting Position: Pressure connection facing downward for best accuracy
  • Maintenance: Not field repairable; repair or recalibration through Dwyer Calibration Services
  • Caution: Do not exceed specified supply voltage ratings; not for 120 or 240 VAC operation

Product Usage Instructions

Dwyer E-111-A-QS Pressure Transmitters
For best accuracy, mount the pressure transmitter with the pressure connection facing downward. Use suitable sealants to prevent leaks when making pressure connections.

Maintenance

Series 626 and 628 transmitters are not field repairable but can be repaired or recalibrated through Dwyer Calibration Services.

Dwyer E-111-A-QS Pressure Transmitters

  • RED: Pressure Transmitter
  • BLACK: Pressure Transmitter
  • [NC]: Not Connected
  • SILVER: Power Supply Receiver (Shield Wire not case grounded)

Dwyer E-111-A-QS Pressure Transmitters

  • RED: Pressure Transmitter
  • BLACK: Common
  • WHITE: +V Out
  • SILVER: Power Supply Receiver (Shield Wire not case grounded)

Dwyer E-111-A-QS Pressure Transmitters
Do not exceed specified supply voltage ratings. Permanent damage not covered by warranty will result. This device is not designed for 120 or 240 VAC operations.

QUICK START

  • Position: For best accuracy, mount with the pressure connection facing downward and use suitable sealants to prevent leaks when making pressure connections.
  • Maintenance: Series 626 and 628 transmitters are not field repairable but can be repaired or recalibrated through Dwyer Calibration Services.

Current output

Dwyer-E-111-A-QS-Pressure-Transmitters-fig-1

Voltage output

Dwyer-E-111-A-QS-Pressure-Transmitters-fig-2

CAUTION Do not exceed specified supply voltage ratings. Permanent damage not covered by warranty will result. This device is not designed for 120 or 240 VAC operation.
For more information, refer to the user’s manual.

Scanner

Dwyer-E-111-A-QS-Pressure-Transmitters-fig-3

Full Manual Printed in U.S.A. 11/23 FR# 443271-55
©Copyright 2023 Dwyer Instruments, LLC

FAQ

  • Q: Can I repair the Series 626 & 628 Pressure Transmitters on my own?
    • A: No, these transmitters are not field repairable. Contact Dwyer Calibration Services for repair or recalibration.
  • Q: What is the recommended power supply voltage for the transmitters?
    • A: The recommended power supply voltage range is 13-30 VDC. Do not exceed this range to prevent damage.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>