AS62L Lightronics Lighting Control Portable Dimmers Owner’s Manual

June 12, 2024
LIGHTRONICS

AS62L Lightronics Lighting Control Portable Dimmers Owner’s Manual
AS62L Lightronics Lighting Control Portable Dimmers

DESCRIPTION

The AS62L is a compact six channel light dimmer. It has a maximum capacity of 1200 Watts per channel and maximum total load capacity of 4800 Watts. It is supplied with two input power cord stubs which may be connected to two different 120 VAC power phases. The AS62L is intended for INDOOR USE ONLY. The unit operates using the industry standard three wire multiplex protocol. The AS62L may be operated in a relay (non-dim) mode. The unit will also function as a chaser and has several preset chase patterns which may be used.

INSTALLATION

LOCATION: Locate the unit vertically with control signal connectors on bottom in a well ventilated area away from moisture and heat. Two ½” holes are provided on the dimmer top cover to install a lighting bar pipe clamp and a suitable safety cable.

POWER CONNECTIONS: Extending from the chassis are two 20 amp line cords for connection to two separate 120 VAC, 20 Amp, grounded services in any phase combination. Total capacity of the AS62L is 4800 Watts.

LOAD CONNECTIONS: There are six numbered duplex outlets on the top of the unit. Each provides two connections for one of the output channels. You can connect up to 1200 Watts of lighting to a single channel. The total load capacity of the AS62L channels 1, 3, and 5 combined is limited to 2400 Watts. The total load capacity of the AS62L channels 2, 4, and 6 combined is also limited to 2400 Watts.

CONTROL SIGNAL CONNECTIONS

The male three pin XLR connector on the unit end panel connects to the control console. The female connector is for connection to additional dimmers. The AS62L dimmer LMX-128 protocol is compatible with the Lightronics and NSI/Sunn three wire multiplexed protocol. If you have older Lightronics dimmers which run in the obsolete Lightronics mode only, contact Lightronics for information on changing the mode. When using multiple dimmers, ALL dimmers MUST be in the SAME mode.

CONTROL SIGNAL WIRING:

Connector Pin # Signal Name
1 LMX Common
2 Console Power
3 Multiplex Signal

AS62L END VIEW
Control Signal

OPERATION

NORMAL MODE (non-chaser)

A green LED in the end panel will indicate that a valid control signal is applied to the unit. A DIP switch block on the end panel selects the starting channel number of the dimmer. The eight right hand switches control this function. For example, if all switch positions are down – the dimmer will respond to channels 1-6. Moving the switch position on the far right up will set the dimmer to respond to channels 3-8. A complete table of channel assignments is provided at the end of this manual.

RELAY MODE Pairs of channels (1/2 and/or 3/4 and/or 5/6) may be switched into the relay mode. In this mode the output of these channels will be either off or full on depending on the control console channel setting. The trip point for turn on is approx. 50%. The three left hand switches on the DIP switch block control relay mode channel selection.

CHASER MODE

When operating in the chaser mode the AS62L becomes independent of the control console and other dimmers. The green LED indicator is OUT when in the chaser mode. Chaser mode is turned on and off by one of the DIP switches on the end of the unit. A diagram on the unit cover shows the switch settings for controlling chaser operation.

Eight different chaser patterns are available. A “bounce” condition may be imposed on several of the chase patterns by setting one of the DIP switches. The bounce condition causes the chase pattern to run in alternating directions.

The chase step time may be controlled for up to 128 seconds per step. Step fade time is proportional to the step time. If a channel is in the relay mode during chaser operation – it will “snap” on and off (zero fade time). The following tables show the details of chaser settings.

ADDRESS AND CONTROL SWITCH SETTINGS

NORMAL MODE SWITCH FUNCTIONS
Switch Setting

CHASER MODE SWITCH FUNCTIONS
Switch Setting

CHASER PATTERN SELECTION
SWITCHES PATTERN
6 channel sequence
6 channel build
6 channel build/unbuild
6 channel random
3 channel sequence
3 channel build
3 channel build/unbuild
2 channel alternating
CHASER TIMING SELECTION
SWITCHES STEP TIME
0.5 seconds
1.0 seconds
2 seconds
4 seconds
6 seconds
8 seconds
12 seconds
16 seconds
24 seconds
32 seconds
40 seconds
48 seconds
56 seconds
64 seconds
96 seconds
128 seconds

MAINTENANCE AND REPAIR

TROUBLESHOOTING
  • Check that power is applied to the dimmer.
  • Check that all light fixtures are functional.
  • Check the fuses.
  • Check the multiplex cable.
  • Check the settings of the dimmer DIP switches.
  • Check the console setup for correct patching
REPAIR

The only user serviceable parts are externally accessible fuses. Replace fuses ONLY with 10 Amp, 250VAC, fast blow fuses. Internal service on the unit by other than Lightronics authorized agents will void the warranty. If service is required, contact the dealer from whom you purchased the dimmer, or Lightronics, Service Department, 509 Central Drive, Virginia Beach, VA 23454. Tel: 757 486 3588.

WARRANTY INFORMATION AND REGISTRATION – CLICK LINK BELOW
www.lightronics.com/warranty.htmlv

CHANNEL ASSIGNMENT SETTINGS

The DIP Switch Setting column shows the positions of the DIP switches on the AS-62L dimmer. The Start Channel column shows the resulting channel assignment for channel 1 of the dimmer. The remaining dimmer channels will automatically be assigned the next 5 consecutive control channels.

EXAMPLE: If the dimmer’s DIP switches are set to then the first channel of the dimmer will respond to console channel 87. The remaining dimmer channels will respond to console channels 88, 89, 90, etc

DIP Switch # and Setting Start Channel

5 6 7 8 9 10 11 12
| 1
| 3
| 5
| 7
| 9
| 11
| 13
| 15
| 17
| 19
| 21
| 23
| 25
| 27
| 29
| 31
| 33
| 35
| 37
| 39
| 41
| 43
| 45
| 47
| 49
| 51
| 53
| 55
| 57
| 59
| 61
| 63
| 65
| 67
| 69
| 71
| 73
| 75
| 77
| 79
| 81
| 83
| 85
| 87
| 89
| 91
| 93
| 95
| 97
| 99
| 101
| 103
| 105
| 107
| 109
| 111
| 113
| 115
| 117
| 119
| 121
| 123
| 125
| 127

Lightronics Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

LIGHTRONICS User Manuals

Related Manuals