CHAUVIN ARNOUX PA40W-2 Power Supply And Battery Charger User Manual

June 10, 2024
CHAUVIN ARNOUX

User’s manual
PA40W-2

CHAUVIN ARNOUX PA40W 2 Power Supply And Battery Charger -
cover

Power supply and battery charger

PA40W-2 Power Supply And Battery Charger

Thank you for purchasing a PA40W-2 power supply and battery charger. This accessory is designed to be used with the Qualistar2 C.A 8345, the Scopix IV and the C.A 6117.

For best results from your instrument:

  • read these operating instructions carefully,
  • comply with the precautions for use.

| WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol appears.
---|---
| Equipment protected by double insulation.
| Indoor use.
| Chauvin Arnoux has adopted an Eco-Design approach in order to design this appliance. Analysis of the complete lifecycle has enabled us to control and optimize the effects of the product on the environment. In particular this appliance exceeds regulation requirements with respect to recycling and reuse.
****| The CE marking indicates compliance with the European Low Voltage Directive (2014/35/EU), Electromagnetic
Compatibility Directive (2014/30/EU), and Restriction of Hazardous Substances Directive (RoHS, 2011/65/EU and 2015/863/EU).
| The UKCA marking certifies that the product is compliant with the requirements that apply in the United Kingdom, in particular as regards Low- Voltage Safety, Electromagnetic Compatibility, and the Restriction of Hazardous Substances.
| The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective disposal in compliance with Directive WEEE 2012/19/UE: This equipment must not be treated as household waste.

Definitions of overvoltage categories

  • Overvoltage category IV concerns equipment installed where the power supply enters a building, or nearby, between the point of entry and the main distribution frame. This equipment can include electricity meters and primary overvoltage protection devices.
  • Overvoltage category III concerns equipment that is part of the electrical installation of a building. This equipment includes sockets, fuse panels, and some network installation control devices.
  • Overvoltage category II concerns equipment designed to be supplied from the electrical installation of the building. It includes both equipment connected by plugs and equipment connected permanently.

PRECAUTIONS FOR USE

This instrument is compliant with safety standard IEC/EN 61010-1 or BS EN 61010-1 and the leads are compliant with IEC/EN 61010-031 or BS EN 61010-031, for voltages up to 300V in overvoltage category III. The protection provided by the instrument may be impaired if it is used other than as specified by the manufacturer.
Failure to observe the safety instructions may result in electric shock, fire, explosion, and destruction of the instrument and of the installations.

  • The operator and/or the responsible authority must carefully read and clearly understand the various precautions to be taken in use. Sound knowledge and a keen awareness of electrical hazards are essential when using this instrument.
  • Comply with the rated maximum voltage and current and the overvoltage category.
  • Never exceed the protection limits stated in the specifications.
  • Observe the conditions of use, namely the temperature, the relative humidity, the altitude, the degree of pollution, and the place of use.
  • Do not use the instrument if it is open, damaged, or incorrectly reassembled. Before each use, check the integrity of the housing, leads and accessories. Any item of which the insulation is deteriorated (even partially) must be set aside for repair or scrapping.
  • Use only the leads and accessories supplied. The use of leads (or accessories) of a lower voltage or category limits the voltage or category of the combined instrument and leads (or accessories) to that of the leads (or accessories).
  • Do not expose the housing to a source of heat or to direct sunlight. Let air flow freely around it to ensure sufficient cooling.
  • When handling the crocodile clips, keep your fingers behind the physical guard.
  • Use suitable personal protection equipment when parts at a dangerous voltage may be accessible in the installation where the measurement is made.
  • All troubleshooting and metrological checks must be done by competent, accredited personnel.

PRESENTATION

DELIVERY CONDITION

The PA40W-2 power supply and battery charger is delivered in a cardboard box with:

  • 1 Schake® -C5 receptacle to mains cord
  • 1 multilingual manual

For the accessories and spares, consult our web site: www.chauvin- arnoux.com

VIEW OF THE PA40W-2

CHAUVIN ARNOUX PA40W 2 Power Supply And Battery Charger -
PRESENTATION

USE

The PA40W-2 power supply and battery charger are used to power the instrument for long-term applications and thereby economize the instrument’s internal battery. It also serves to recharge the battery.

  • Connect the Schake ® -C5 mains cord to a mains socket.
  • Open the elastomer cap and connect the specific connector of the power supply to the instrument.

CHAUVIN ARNOUX PA40W 2 Power Supply And Battery Charger -
USE

The indicator lights:

  • green to indicate the power-on condition,
  • then orange to indicate that the battery is charging,
  • and finally green to indicate that the charge is complete.

If it blinks, the battery is missing and the instrument is powered by the external power supply alone.

TECHNICAL CHARACTERISTICS

REFERENCE CONDITIONS
Quantity of influence Reference values
Temperature 23 ± 3 °C
Relative humidity 45 to 55 %HR
Electric field < 1 V/m
Magnetic field < 40 A/m
ELECTRICAL CHARACTERISTICS

INPUT CHARACTERISTICS

  • Voltage range: 110 to 230 V at a frequency from 0 to 440 Hz.
  • Overload tolerance: ± 15% permanent.
  • Input current: 0,8 Arms max
  • Apparent power: 88 VA

OUTPUT CHARACTERISTICS

Characteristics Values
Permanent output power 40 W
Output voltage @ 40W 15 V ± 4%
Maximum output current 2.67 A without battery charging 1.67 A with battery

charging
Maximum no-load output voltage| 16 V
Ripple of the output voltage|  300 mars
Maximum short-circuit duration| Permanent
Starting-up time at 110V| < 1.5 s

EFFICIENCY
The efficiency is 85% at 40 W.

CHARGER
Charging current: 1A.
Charging voltage: 7.5 to 12.5 V

ENVIRONMENTAL CONDITIONS

Range of operation: from 0 to 50°C, from 30 to 95%RH without condensation.
Range of storage: from -25 to +85°C, from 10 to 90%RH without condensation.
Indoor use.
Altitude : < 2000 m
Degree of pollution: 3

MECHANICAL CHARACTERISTICS
Dimensions (L x D x H) 160 x 80 x 57 mm
Lead 1.80 m, terminated by a specific 4-point connector.
Mass approximately 630g.
Inrush protection IP 54 per IEC 60529.

IK 04 per IEC 62262.
Drop| 1 meter.

COMPLIANCE WITH INTERNATIONAL STANDARDS

The instrument is compliant with IEC/EN 61010-1 or BS EN 61010-1 and IEC/EN 61010-031 or BS EN 61010-031 for a voltage of 300V in overvoltage category III with degree of pollution 3.

ELECTROMAGNETIC COMPATIBILITY (CEM)

The instrument is compliant with standard IEC/EN 61326-1 or BS EN 61326-1.

MAINTENANCE

The instrument contains no parts that can be replaced by personnel who have not been specially trained and accredited.
Any unauthorized repair or replacement of a part by an “equivalent” may gravely impair safety.

CLEANING

Disconnect the unit completely.
Use a soft cloth, dampened with soapy water. Rinse with a damp cloth and dry rapidly with a dry cloth or forced air. Do not use alcohol, solvents, or hydrocarbons.

WARRANTY

Except as otherwise stated, our warranty is valid for 24 months starting from the date on which the equipment was sold. The extract from our General Conditions of Sale is available on our website.
www.group.chauvin-arnoux.com/en/general-terms-of-sale
The warranty does not apply in the following cases :

  • Inappropriate use of the equipment or use with incompatible equipment;
  • Modifications made to the equipment without the explicit permission of the manufacturer’s technical staff;
  • Work done on the device by a person not approved by the manufacturer;
  • Adaptation to a particular application not anticipated in the definition of the equipment or not indicated in the user’s manual;
  • Damage caused by shocks, falls, or floods.

FRANCE
Chauvin Arnaut
12-16 rue Sarah Bernhardt
92600 Aspires-sur-Seine
Tell : +33 1 44 85 44 85
Fax : +33 1 46 27 73 89
[email protected]
www.chauvin-arnoux.com| INTERNATIONAL
Chauvin Anoud
Tell : +33 1 44 85 44 38
Fax : +33 1 46 27 95 69
Our international contacts
www.chauvin-arnoux.com/contacts
---|---

696415A00 – Ed. 1 – 07/2022 © Chauvin Arnaut
All rights reserved and reproduction prohibited

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CHAUVIN ARNOUX User Manuals

Related Manuals