PROLED L37430x2G Flex Tube Side View 3w Mono 2g

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-1

Product Information

The Flex Tube Side View 3W Mono 2G is a flexible LED light strip that emits white or warm white light. It is manufactured by MBN GmbH and has dimensions of 17 x 16 mm. The product has a minimum bend diameter of 300 mm and a protection rate of IP67, which means it is dust tight and can withstand immersion in water up to a depth of 1 meter. The product can be cut to any length and has 7 LEDs per segment with a power output of 13 W/m.

Technical Data

  • Dimensions: 17 x 16 mm
  • Min. bend diameter: 300 mm
  • Protection rate: IP67
  • Light color: White / Warm White
  • Cuttable: Yes
  • LEDs per segment: 7
  • LED power: 13 W/m

Cautions

  1. Disconnect the mains before making any cuts, installation, maintenance or connection.
  2. All connector joints must be connected correctly to achieve IP67 rating.
  3. Operate the flex light by instructions and confirm the work voltage matches the product requirements.
  4. Confirm the polarity of connector before insertion front connection cable.
  5. Connect and cut the product correctly. Any wrong operation will damage the product.
  6. Use qualified DC power supply.
  7. Use and bend the flex tube correctly as shown in the figures on the right.
  8. Do not operate light when the ambient temperature exceeds the range of specified temperature in User Manual.
  9. Do not energize the light over 30 minutes in coil packaging.

Product Usage Instructions

  • Unpacking
    If the product was purchased in reel packaging, two people are needed to uncoil the light. If purchased in box packaging, simply remove the product from the box.

  • Cutting
    The Flex Tube Side View 3W Mono 2G is cuttable, and a cutting line is provided in the user manual. Cut the product to the desired length along the cutting line.

  • IP67 Connector and End Cap
    The user manual provides instructions for installing the IP67 connector and end cap. Follow these instructions carefully to ensure proper installation and achieve IP67 rating.

  • Mounting
    The Flex Tube Side View 3W Mono 2G can be mounted using mounting profile options provided in the user manual. Follow the instructions to mount the product correctly

Troubleshooting

If you encounter any issues with the product, refer to the troubleshooting section in the user manual for assistance.

Unpacking

Note: Two people are needed to uncoil the light.

Avoid doing this:PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-
2g-2

What’s In the box

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-3 PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-4

Box Packaging

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-5

Technical Data

  1. Dimensions
  2. Min. bend diameter: 300 mm
  3. Protection rate: IP67
  4. The product IP rate is ultimately in line with properly applied IP rated connectors.
  5. Working ambient temperature: -20°C – 45°C.
  6. Environmental Installation Temperature: 0°C – 45°C.
  7. This product contains a light source of Energy class F (L3743062G) or Energy class E (L3743042G).
  8. The light source in the containing product can not be replaced.

Note: Max. length per power input: Indoor (constant temperature) singel end max. 15 m, double end max. 30 m.
Outdoor (because of temperature fluctuations and different thermal expansion coefficients of the materials) max. 7m

Light colour Cuttable all LEDs per segment LED power
White 5,56 cm 7 13 W/m
Warm White 5,56 cm 7 13 W/m

Cautions

  1. Before making any cuts, installation, maintenance or connection, be sure the mains is disconnected!
  2. Note: all connector joints must be connected correctly to achieve IP67 rating.
  3. Please operate this flex light by instructions, and confirm the work voltage, it must match with product requirements.
  4. Please confirm the polarity of connector before insertion front connection cable.
  5. Connect and cut this product correctly. Any wrong operation will damage this product.
  6. Use qualified DC power supply.
  7. Please use and bend this flex tube correctly. See the figures on the right.
  8. Do not operate light when ambient temperature exceeds the range of specified temperature in User Manual.
  9. Do not energize the light over 30 minutes in coil packaging.

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-8

WARNING : The above wrong approaches will damage the light.

Cutting instructions

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-9 PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-10

Note

  1. Place the tube horizontally when cutting it.
  2. Use only factory-recommended cutter.
  3. Cut the tube according to the following instructions. The incorrect operation will damage the tube.

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-11

IP67 connector

Please ignore these steps, if the front connector has been assembled before delivery.
Note

  1. Never wet the assembly units or assemble with wet hands.
  2. Please use the tools correctly.
  3. Please pay attention to personal security when using tools.

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-12

Components of Front Connector

Note: The tube ends are marked with either an 01 or an 02. Always make sure to use an identically labeled connector for the appropriate direction .PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-13

Tools

Installation Steps

  1. Placing PC CoverPROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-16
  2. Inducing a Cavity for Feed ConnectorPROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-17
  3. Inserting the Feed Connector PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-18
  4. Treatment of Anti-skidding Clip PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-19
  5. Installation of Anti-Skidding ClipPROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-20
  6. Installation of U Steel Plate and PC Cover

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-21 PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-
2g-21Please energize the tube to check its functionality and do waterproof reliability testing after connector assembly.
Slide back the PC cover till it snaps in the feed connector.

IP67 End cap

Please ignore these steps, if the End Cap has been assembled before delivery .PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-24

  1. Components of End CapPROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-25
  2. Tools

Installation Steps

  1. Placing PC CoverPROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-16
  2. Inducing a Cavity for Feed ConnectorPROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-17
  3. Inserting the Feed Connector PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-18
  4. Treatment of Anti-skidding Clip PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-19
  5. Installation of Anti-Skidding ClipPROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-20
  6. Installation of U Steel Plate and PC Cover

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-21 PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-
2g-21

Diagram of Tube Wiring

Monochrome Tube Wiring

Note

  1. This Flex Tube must be used in conjunction with 24 VDC power supply
  2. Always observe proper polarity
  3. Ensure to add 20% buffer when sizing power supply
  4. Ensure that the power cable carried current is no greater than 80% of it‘s capacity
  5. To minimize voltage drop and keep light consistency, position power supply nearest to the power feed end of Flex Tube and keep the power line as short as possible.

PROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-2g-34

Note: Max. length per power input: Indoor (constant temperature) singel end max. 15 m, double end max. 30 m.
Outdoor (because of temperature fluctuations and different thermal expansion coefficients of the materials) max. 7m

Mounting Profiles

Self-locking Aluminum Profile with clipPROLED-L37430x2G Flex-Tube-Side-
View-3w-Mono-2g-35

Model| W x H(mm)| Length(mm)| L1(mm)| L2(mm)| L3(mm)| L4(mm)| Screw Hole(mm)| Hole Number| Clip Number
---|---|---|---|---|---|---|---|---|---
L374A17| 20.5×22.0| 2000| 25| 200| 125| 350| Ø 3.5| 10| 6

Installation Guide

Prepare for InstallationPROLED-L37430x2G Flex-Tube-Side-View-3w-Mono-
2g-36

Correct Installation of Standard Aluminum ProfilePROLED-L37430x2G Flex-
Tube-Side-View-3w-Mono-2g-37PROLED-L37430x2G
Flex-Tube-Side-View-3w-Mono-2g-38

Requirements and Cautions for Installation of Mounting Profile
For Tubes with IP67 connectorsInstall tube in one direction. Don’t let it choke anywhere.

  1. Bending in the Process of Installation

Troubleshooting

  • The whole tube doesn’t work.
    • Check power supply is plugged in, switched on and receiving power.
    • Check all tube, dimmer or controller connections, connection from the power supply to flex tube.
    • Check polarity of all wire connections.
    • Make sure power supply output voltage is 24V DC.
    • Check front connector is inserted into backside of PCB and properly assembled.
  • Light emitting appear dim or dull at one end.
    • Check whether the output voltage of the power supply is lower than that of tube.
    • Adjust the dimming level to the maximum.
    • Power from both ends or shorten tube length to prevent voltage drop.
  • Light emitting appear excessive brightness.
    • Check whether the output voltage of power supply is higher than that of tube.
    • Check whether the power grid is stable.
  • If the first segment doesn’t work.
    • Cut not in indicated cutting line or not in a straight line. Cut out and remove the first segment.
    • Damage was caused to the first LED when inserting the front connector to the right side of PCB. Cut out the first segment and properly assemble the connector.
    • Water ingress due to poor connector assembly could cause a short circuit of first segment. Replace length with a new one. External impact damage inside LEDs. Only use your hands to install flex tube into aluminum profile.
  • Flex tube is flashing on and off.
    • Check the power supply to ensure it supports the length you are using. Select the appropriate strength or install an additional power supply to
    • support your installation.
    • Check power supply output voltage is stable.
    • Check front connector is properly installed with good contact with the copper PCB.
    • Check proper controller is connected for tube working.