Qlima PGC 3009 Gas Heater Instruction Manual

June 11, 2024
Qlima

Qlima PGC 3009 Gas Heater

Part No. Part name QTY
A  Mesh 1
B Heating Body 1
C  Cylinder Housing 1
D   Base 1
E Wheel 1
Part No. Part name QTY
--- --- ---
AA Bolt M8 x 16 2
BB Nut M8 2
CC Screw M5 x 8 8
DD  M6 Nut 1
EE Philips screwdriver 1
FF  Wrench 1
GG  AA battery (1.5V) 1
Model name PGC 3009
--- ---
Gas patio heater Hs / Qn = 11 kW
 Gas category I3B/P(30) propane, butane or their mixtures at 28-30 mbar,

G30/G31: 30 mbar* // I3+ bu- tane at 28-30 mbar / Propane at 37 mbar, G30: 28-30 mbar,

G31: 37 mbar**

Consumption (max. )| (G30:800g/h; G31:786g/h)
| Countries of Destination

FOR OUTDOOR USE ONLY. Close the valve of the gas cylinder or the regulator after use. The use of this appliance in enclosed areas is DANGEROUS and is PROHIBITED. Read the instructions before using this appliance. The appliance must GB – FOR OUTDOOR USE ONLY. Close the valve of the gas cylinder or the regulator after use. The use of this appliance in enclosed areas is DANGEROUS and is PROHIBITED. Read the instructions before using this appliance. The appliance must appliance requires a hose and regulator, always use a suitable and approved low pressure regulator. In case of doubt contact your local gas supplier.

PVG Holding B. V., Kanaalstraat 12 C, 5347
KM, Oss, the Netherlands
PO. Box 96, 5340 AB OSS, The Netherlands
Qlima.com | Made in PRC
PIN 0063BU7882

DIRECTIONS FOR USE

This heater is for outdoor use only. Indoor use is dangerous and strictly forbidden. Always use in amply ventilated areas. An amply ventilated area must have a minimum of 25% of the surface area open. The surface area is the sum of the walls surface.

  • Read this user manual carefully before using the appliance and keep it for future reference. Install this device only when it complies with local/national legislation, ordinances and standards.
  • The gas fired patio heater is designed for outdoor use only, it will provide radi- ant heat which warms people and objects rather than the air in between.
  • This product is intended to be used as patio heater around residential houses in normal household conditions and environment.
  • After unpacking, check the appliance for any damages. When in doubt, do not use the appliance, but contact customer service at your local dealer’s. Keep the packaging materials (plastic bags, etc.) away from children, as they may cause hazardous situations to children.
  • No modifications to the safety system are allowed.
  • Do not remove the injector. This product cannot be converted from one gas to another. Removing or changing the injector is strictly forbidden. When the injector is marked with 1,9 this indicates that the size of the injector is 1.9 mm.
  • This heater is constructed in conformity with relevant texts in the EN14543:2017 standard and with Gas Appliance Regulation EU/2016/426.
  • Keep the instructions for future reference.

Warnings

  • Read the instructions before installation and use. This appliance must be installed and the gas cylinder stored in accordance with the regulations In force.

  • Only use the device for its intended purpose. Other usage may lead to burns, fire, explosion, crash, etc.

  • Install the heater only if it complies with local regulations, laws and standards;

  • Check if the information indicated on  the type plate corresponds your situationbefore you connect the appliance.

  • Install the heater according to the instructions as described in the installation section of the directions for use;

  • This heater is manufactured according to CE safety standards. Nevertheless, as with any other heating device, care must be taken;

  • RISK OF FIRE Never use the heater in places where inflammable and/or harmful Gases, products or fumes may be present (e.g. exhaust gases, paint fumes, curtains, paper, clothes);

  • If the heater is positioned too close to inflammable materials you may risk fire;

  • For safety reasons take care when children or animals are in the proximity of the heat-er, as with any other heating device, and make sure that children are always aware of the presence of a hot heater;

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  • If the heater is damaged, it shall be repaired by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  • Children should be supervised to ensure that they do not play with the appliance.

  • In order to avoid overheating, do not cover the device.

  • The guard of this heater is intended to prevent direct access to heating elements and must be in place when the heater is in use.

  • Do not insert objects into the openings of the device.

  • The guard does not give full protection for young children and infirm persons.

  • This appliance can be used by children aged from 12 years and above and persons with reduced physical, sensory or men – tal capabilities or lack of experience and knowledge if they have been given super vision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

  • Cleaning and user maintenance shall not be made by children without supervision.

  • Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the  appliance in a safe way and understandthe hazards involved.

  • Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.

  • CAUTION – some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.

  • During operation and just after operation the appliance will be extremely hot. NEVER touch it during operation or just operation. NEVER move the appliance during this time.

  • Switch off the appliance when it is unattended.

  • Do not cover or obstruct the heater when in use. If you fail to consult and/or follow up the rules, instructions and explanation, the warranty will no longer be valid, and the manufacturer will no longer deal with any damage to the appliance and/or your environment under the warranty.

  • Read the instructions before installation and use.

  • This appliance must be installed and the 66 4 gas cylinder stored in accordance with the regulations in force.

  • Do not obstruct the ventilation holes of the cylinder housing.

  • Do not move the appliance when in operation.

  • Shut off the valve at the gas cylinder and/ or the regulator:
    a. before moving the appliance
    b. after use

  • The tubing or the flexible hose must be changed within the prescribed intervals

  • Use only the type of gas and the type of cylinder specified by the manufacturer

  • In case of violent wind particular attention must be taken against tilting of the appliance

  • Have any repairs and/or maintenance carried out by a recognized service engineer only

  • Make sure that the correct gas is used and that the gas containers are not exposed to heat or extreme temperature changes. Always store the gas containers in a cool, dry and dark place.

  • Always use a suitable and approved low-pressure regulator. In case of any doubt contact your local dealer.

  • Use only the type of gas and the type of cylinder specified by the manufacturer.

  • In case of violent wind particular attention must be taken against tilting of the appliance

  •  The tubing or the flexible hose must be changed within the prescribed intervals

  • Turn of the appliance immediately if smell of any gass is detected and extinguish any open flame.

ASSEMBLING THE HEATER

The manufacturer is not responsible for any harm or damage if attention is not paid to the points described above. The use of this product and the elements required for that purpose is entirely at the end user’s own risk.

HEATER LOCATION AND CLEARANCE

Always maintain: (Pic.1)

  • 120 cm clearance from combustible materials,
  • minimum 100 cm top clearance
  • minimum 100 cm side clearance
  • Heater must only be placed and used on a firm, level and stable underground.
    ASSEMBLING THE HEATER

WARNINGS

  • Never use the heater while it is raining.
  • Always turn off the heater while there is a rain.
  • Always ensure the heater stands firmly.
GAS REQUIREMENTS

Use propane, butane or LGP only. See rating label on the appliance.

  • Maximum size of cylinder suitable for the appliance is Ø 32 cm x 59 cm (high).

  • Gas supply to the appliance from the gas cylinder: the appliance requires
    approved gas hose in 60-80 cm length and a gas regulator. The hose and regulator assembly must conform to local standard codes.

  • Regulator maximum inlet pressure must not exceed 690 kPa.

  • Always use a fixed pressure regulator (without adjustment wheel) with a fixed outlet pressure of be 28 mbar (2.8 kPa) to 37 mbar (3.7 kPa), depending on countries.

  • The installation must conform to local codes, or in the absence of local codes, to the standard for the storage and handling of liquid petroleum gases.

  • A dented, rusted or damaged gas cylinder may be hazardous and should be checked by an authorized dedicated gas specialist.

  • Never use a gas cylinder with a damaged valve connection.

  • The gas cylinder must be arranged to provide for vapor withdrawal from the operating cylinder.

  • Never twist the flexible tubes and hoses.

  • Disconnect the gas cylinder when the heater is not use.

  •  Do not connect the gas cylinder directly to the appliance without regulator.

  •  Use only the type of gas and the type of cylinder specified in these instructions.

LEAK TESTING

Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness check must be performed at the installation site due to possible mishandling in shipment and/or installation or because of excessive pressure being applied to the heater. The heater must be checked with a full cylinder.

  1. Make sure the safety control valve is in the OFF position.

  2. Make a soapy water solution of one part liquid detergent and one part water. The soapy water solution can be applied with a spray bottle, brush or rag to all gas connections. Soap bubbles will appear in case of a Ieak.
    WARNING: Never leak test while smoking!
    WARNING: In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut off and the appliance shall be investigated and rectified before it is used again.

  3. Turn the gas supply ON. And check all the connections with the soapy water solution. No bubbles may appear!

  4. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply ON and recheck. Contact your dealer or gas supplier for assistance if bubbles continue to appear.

DIAGRAMMATICAL REPRESENTATIONS OF OUTDOOR AREAS

DIAGRAMMATICAL REPRESENTATIONS OF OUTDOOR AREAS

ASSEMBLY

Parts supplied

  • Pic. 3 & Pic. 4
    ASSEMBLY
    ASSEMBLY
    Step 1: Pic. 5

  • To protect heater from strong wind, anchor the base securely to the ground with screws. Use the 3 pieces ground fixer as shown in the picture.
    ASSEMBLY
    Step 2: Pic. 6
    ASSEMBLY
    Step 3: Pic. 7
    ASSEMBLY
    Step 4: Pic. 8
    ASSEMBLY
    Step 5: Pic. 9

Step 6: Pic. 10

  • Unscrew ignitor button, place battery, tighten button again.

OPERATION

  • Connect the gas hose to the gas connector.
    Please note:

    • The gas hose is NOT included with the heater. Hose must be purchased separately
    • Minimum / Maximum length gas hose: 60-80 cm
    • Gas connector suitable for:
    • Ø 8-12 mm hose (all EU countries except France)
    •  G1/2’’ (France only)
  • For gas hose with threaded connectors: bind 2 or more rounds of plumbing tape around the gas pipe before connecting the gas hose for security.

  • Bind 2 or more rounds of Teflon plumbing tape around the gas burner inlet connector and connect the gas pipe. Use a wrench to tighten the connection.

  • Connect the other end of your gas hose according to the mounting instruction as supplied with the gas hose and/or supplied with the gas regulator see picture 9.
    Note:

    • The gas hose is NOT included with the heater
    • The gas regulator is not included with the heater
  • Connect the regulator to the gas cylinder (not included) according to the mounting instruction as supplied together with the gas regulator and/or the gas cilinder

  • Put gas cylinder on the base.

WARNING! Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a fire. After the cylinder is placed inside the heater, secure the cylinder with block belt tightly. The heater must be fixed on a stable and strong table with a minimum height of 40cm from floor level.

TO TURN ON THE HEATER

Check that the regulator seal is correctly fitted and able to fulfil its function
Before starting, always do a leak test. See section “leak testing”.

  1. See picture 11

  2. Make sure the turnable knob at right hand side is in ‘off’ position

  3.  Fully open the gas cylinder – make sure that gas can flow unhindered towards heaters

  4. Press and turn knob B to “PILOT” position.

  5. Press down knob B and hold it pressed for 60 seconds. While keeping knob B pressed, press ignitor button A several times until the pilot flame inside the heater lights. Make sure to keep pressing knob B for 20-40 seconds after pilot flame is lit.

  6. 20-40 seconds after pilot flame is lit: release knob B and stop pressing ignitor button A

  7. Now turn the knob B to ‘HIGH” position and leave it there for 5 minutes or more before turning the knob to the desired temperature position.

Note:

  1. If a new tank has just been connected, please allow at least one minute or more for the air in the gas pipeline to purge out through the pilot hole,
  2. If the pilot light has not ignited, turn heater control knob to OFF position, fully close gas valve, wait 5 minutes, then repeat steps 1-7 of the Lighting Instructions.
    If the burner flame goes out accidentally or it is blown out by wind, turn off the heater and wait at Ieast 5 minutes or more to let the gas dissipate before re-lighting to avoid possible gas explosion. Repeat steps 1 to 7.

| ES| FR| GB| IT| NL| PT| SLO
---|---|---|---|---|---|---|---
| Apagado| Off| Off| Spenta| Uit| Off (Desligado)| Off
| Posición de encen- dido| Position d’allumage| Ignite posi- tion| Posizione di accen- sione| Ontstekings positie| Posição para acen- der| Vžgite položaj

LOW

| Capacidad baja| Capacité faible| Low capac- ity| Bassa capa- cità| Laag ver- mogen| Baixa capa- cidade| Nizka kapaciteta

HIGH

| Alta capa- cidad| Capacité élevée| High capacity| Alta capa- cità| Hoog ver- mogen| Elevada capacidade| Velika kapaciteta

Table 1

TO TURN OFF THE HEATER
a) Fully close the gas valve of the regulator or the gas valve at the gas bottle.
b) Turn control knob clockwise from “PILOT” to “OFF”: press knob B in oder to be able to turn to “OFF”.

WARNINGS

  • The whole gas system. hose, regulator, pilot and burner should be inspected for Ieak before use. But at least once a month and each time the gas cylinder is changed. Check the hose assembly for sign of extreme abrasion, cuts or wears. Suspected areas should be Ieak tested. If the hose Ieaks, it must be replaced with a new one that conforms to IocaI standard codes. ). If it shows signs of cracking, splitting or other deterioration it shall be exchanged for new hose of the same length and of the equivalent quality.
  • Make sure the ventilation opening of the cylinder enclosure, controI compartment, burner and circulation air passageways of the heater are free and clear of debris. If debris, spider or insect nests are found, clean the holes with heavyduty pipe cleaner or compressed air.
  • Always keep a dry chemical fire extinguisher readily available.
  • For safety, always allow a 5-minute complete shut off period before re-lighting a hot heater.
  • Replace the gas tube/hose within the interval described with the hose.
REPLACING THE GAS CYLINDER
  • Shut off heater.
  • Fully close the gas valve of the regulator or the gas valve at the gas bottle.
  • Disconnect the regulator from the cylinder following the instructions that came with your regulator.
  • Replace the cylinder.
  • Make sure there is no flame. Only when no flame: remove the plug or seal 4 cap from the cylinder valve.
  • Check for the presence and good state of the gasket before connecting the regulator to the new cylinder
  • Check that the regulator seal is correctly fitted and able to fulfil its function.
  • Perform leak test using soapy water solution.
    WARNING: only change the gas cylinder in a amply ventilated area, away from any ignition source (candle, cigarettes, other flame producing appliances, …).

STORAGE

  • Make sure the heater is in off position
  • Always close the valve of the gas cylinder after use or in case of a disturbance.
  • Disconnect the gas container from the gas heater.
  • Store the gas container in a well-ventilated room. Position it far away from inflammable, explosive or hot materials and preferably not in the home. In addition it should never be stored in the basement or attic.
  • Cylinder must be stored out of the reach of children.
  • Disconnected cylinder must have threaded valve plugs tightly installed and must not be stored in garage or any other enclosed area. Only store in ventilated area!
  • Storage of heater indoors is permissible only if the cylinder is disconnected and removed from the heater.
  • Check the tightness of the connections of the gas line supply (gas cylinder valve / regulator, regulator/hose, hose/appliance inlet). If you suspect a damage, have it changed by your gas dealer.
  • Never store liquid gas cylinder in a sub-terrain, or at places without adequate air ventilation.

CLEANING AND CARE

Warning: Make sure the heaer is in off position and is cool!
Warning: Do not clean heater with cleaners that are combustible or corrosive.

  • Wipe off powder coated surfaces with soft, moist rag and soap water.
  • Remove debris, spider and insect nests from ventilation opening of the cylinder enclosure, control compartment, burner and circulation air passageways of the heater with heavy duty pipe cleaner or compressed air to keep appliance clean and safe for use.
  • Never clear ports or other openings with toothPic.ks or other article that will break and block the ports.
  • If carbon deposits develop, remove the reflector and flame screen and clean them with soap water.
  • Do not paint the flame screen, control panel or reflector.
  • Cover the burner unit with the optional supplied protective cover when the heater is not in use. Wait until the heater is cool before covering.
  • In a salt-air environment, such as near an ocean, corrosion occurs more quickly than normal. Check frequently for corroded areas and repair them promptly.

TROUBLESHOOTING

Review these tips first and you may not need to call for service.

Problem Probable cause Solution
Pilot will not light Gas valve / gas valve on gas cylinder / gas valve on
regulator may be OFF Turn the gas valve ON.
Tank fuel empty Refill gas tank.
Pilot injector blocked Clean pilot injector.
Air in supply system Purge air from lines by pres- sing the control knob

until you smell gas.
Loose connections| Check all fittings.
Low gas pressure| Replace cylinder with a new cylinder.
Pilot will not stay on| Lack of fuel pressure| Keep the variable knob depressed for 10-20 seconds or more after the pilot light ignited.

Tank near empty. Refill gas tank.

Debris around pilot| Clean dirty area.
Loose connections| Tighten connections.
Gas Ieak in Iine| Check connections.
Burner will not light| Pressure is low| Tank near empty.Refill gas tank.
Opening blocked| Remove and clean.
ControI is not 0N| Turn valve to ON.
Pilot light assembly bent| Place pilot properly.
Not in correct location| Position properly and retry.
Burner flame is low| Supply hose is bent or twisted| Straighten hose and per- form leak teston hose.
Blockage in burner injector| Clean or replace burner injector.
Burner flame goes off immediately after ignition| Low gas pressure| Let the pilot flame stay lit for 10 minutes before set- ting variable knob to LO.
Emitter glows une- ven| Blockage in burner injector| Clean burner injector
Base is not on a leveI surface| Place heater on a IeveI surface
Low gas pressure| Replace cylinder with a new cylinder.
Thick black smoke| Blockage in burner| Turn off the heater and Iet it cool.

Remove blockage and clear burnerinside and outside.

Carbon build-up| Dirt or film on reflec- tor and flame screen| Clean reflector and flame screen.

END OF LIFE TIME

If it is decided that the gas heater is not to be used any more, it is recommended that it be disconnected from the gas container. Also cut the rubber hose. If children play with the heater, make sure that dangerous parts are removed.
Never dispose of non-biodegradable products in the environment, but dispose of them in accordance with current national legislation. At the end of its lifetime, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection center or to a dealer providing this service.
Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving from inappropriate disposal and enables the constituent materials to be recovered in order to make significant savings in energy and resources. As a reminder of the need to dispose of household appliances separately.

WARRANTY PROVISIONS

The appliance is supplied with a 24-month guarantee, commencing on the date of purchase. All material and manufacturing defects will be repaired or replaced free of charge within this period. The following rules apply:

  1. We expressly refuse all further damage claims, including claims for collateral and/or consequential damage.
  2. Repairs to or replacement of components within the guarantee period will not result in an extension of the guarantee.
  3. The guarantee is invalidated if any modifications have been made, non-genuine parts are fitted or repairs are carried out by third parties.
  4. Components subject to normal wear, such as filters, batteries, lamps and heating elements are not covered by the guarantee.
  5. The guarantee is valid only when you present the original, dated purchase invoice and if no modifications have been made to it.
  6. The guarantee is invalid for damage caused by neglect and/or by actions that deviate from those in this instruction booklet.
  7. Transportation costs and the risks involved during the transportation of the appliance or components of the appliance shall always be for the account of the purchaser
  8. Damage caused by not using suitable spare parts is not covered by the guarantee.
    To prevent unnecessary expense, we recommend that you always first carefully consult the instructions for use. Take the appliance to your dealer for repairs if these instructions do not provide a solution.

www.Qlima.com

Qlima Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals