3xLOGIC S1 Gunshot Detection Single Sensor User Guide

June 11, 2024
3xLOGIC

3xLOGIC Logo3xLOGIC S1 Gunshot Detection Single Sensor Gunshot Detection
S1 Single Sensor
Quick Start Guide Rev 1.0
Simple. Scalable. Secure.

Introduction

Gunshot Detection from 3xLOGIC is a sensor that detects the shockwave / concussive signature of any gun caliber. It detects up to 75 feet in all unobstructed directions or 150 feet in diameter. The smaller directional sensor that detects the strongest signal determines the source of the gunshot. The sensor is a stand-alone product that can send gunshot detection information using its on-board processors to a variety of host systems including alarm panels, central stations, video management systems, access control  systems and other critical notification systems. No other equipment is necessary for the sensor to identify a gunshot. It is a self-contained device that can complement any security system. 3xLOGIC Gunshot Detection can be used as a single device or is scalable in design and deployments can include an unlimited number of sensors.
Note: Gunshot Detection must be installed and configured by 3xLOGIC authorized technicians only.

Hardware

The Gunshot Detection S1 Single Sensor units have two variations.
2.1 Available Units

  1. Weather Resistant Aluminum Indoor/Outdoor model in Gray
  2. ABS Fade Resistant Plastic Indoor Model in White

2.2 Box Contents
S1 Unit
Corner Mount Bracket
Antenna (Aluminum Unit Only)
This antenna must be installed on the top of the unit.

Connection

Connect the S1 Unit to Power and the Alarm Panel.
The power cable and relay contacts are connected to the 8 Pin Quick Connector
on the board in the back of the unit pictured below.
Warning: Please insure correct polarity.
A voltage range from 12v – 14v DC is acceptable. Connect the Alarm Relay to the Alarm Panel utilizing the NC or NO and C connection denoted on the board.
Note: The installation wiring should have a Gauge of AWG 22 to 20.

3xLOGIC S1 Gunshot Detection Single Sensor - Figure

As annotated above, polarity and connections are denoted on the internal board, with a configuration of: (NO C NC) (NO C NC) 12- 12+
Optional: Connect the Trouble Relay to supervise the power of the unit by connecting to the Trouble NC or NO and C connection denoted on the board.

Mounting

The unit can be mounted to the wall or ceiling.
4.1 Ceiling Mount
When mounting to ceiling, utilize the two holes on the back of the unit and secure to a standard single-gang electrical box.
4.2 Wall Mount
When mounting to the wall, it is recommended using the corner mounting bracket provided in the box. However, the unit may be installed on a flat wall with the understanding the sensor has a 160° detection area.

3xLOGIC S1 Gunshot Detection Single Sensor - Wall
Mount

  1. Install the unit onto the mounting bracket before placing bracket on the wall.
  2. Install two mounting screws in the wall. Leave .25 inches of screw shaft to slide the mounting bracket onto.

Testing

The S1 can be put into test mode 2 ways:
Utilizing a magnet placed under the sensor hole on the front of the unit.
Utilizing the TSTU device (Part # STU01, sold separately).
5.1 Initiate Test
Test Mode is indicated by the blue light blinking 3 times then blinking every .5 seconds. At this time an air horn can be used to test the unit. When the unit detects the air horn, the blue light will stay on for 5 seconds.
5.2 Reset
To turn off test mode, place magnet below the sensor hole again. Standard operation mode will be indicated by the blue light blinking 3 times then a green light only after the unit resets.

Reference Information

6.1 Catalog
These components are available from 3xLOGIC.

PART # DESCRIPTION
SentCMBW Gunshot Detection with Ceiling Mount (White)
SentCMBB Gunshot Detection with Ceiling Mount (Black)
SentCMBWPO PoE Unit with Ceiling Mount (White)
SentCMBBPOE PoE Unit with Ceiling Mount (Black)
WM01W Wall Mount (White)
WM01B Wall Mount (Black)
CM04 Flush Ceiling Mount
STU01 Touch Screen Testing Unit (TSTU)
SP01 Screen Puller Tool to Safely Remove Screens
TP5P01 Telescoping Testing Pole (quantity 5 pieces)
SRMP01 Transducer Screen Replacement Master Pack (100 pieces)
UCB01 Gunshot 8 Sensor Protective Cage (Black)
UCW02 Gunshot 8 Sensor Protective Cage (White)
UCG03 Gunshot 8 Sensor Protective Cage (Grey)
PCB01 Gunshot 8 Sensor Protective Cover (Black)
PCW02 Gunshot 8 Sensor Protective Cover (White)
PCG03 Gunshot 8 Sensor Protective Cover (Grey)

6.2 Company Details
3xLOGIC INC.
11899 Exit 5 Parkway, Suite 100, Fishers, IN 46037
www.3xlogic.com | (877) 3xLOGIC
Copyright ©2022 All rights reserved.

3xLOGIC Logo www.3xlogic.com

Documents / Resources

| 3xLOGIC S1 Gunshot Detection Single Sensor [pdf] User Guide
S1 Gunshot Detection Single Sensor, S1, Gunshot Detection Single Sensor, Detection Single Sensor, Single Sensor, Sensor
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

3xLOGIC User Manuals

Related Manuals