MITSUBISHI ELECTRIC SG-1-SD Package Air Conditioner Snow Guard Installation Guide
- June 11, 2024
- Mitsubishi Electric
Table of Contents
MITSUBISHI ELECTRIC SG-1-SD Package Air Conditioner Snow Guard
Product Information
The IM_SG-1-SD is an optional part for a package air conditioner snow guard installation. It includes SD LHS Panel, SD Panel, SD RHS Panel, and SD Service Panel along with 16 special screws and 2 lanyards. The product comes with installation hardware andscrews.
Product Usage Instructions
- Always keep safety in mind while installing the optional parts. Read the safety precautions and follow them carefully to avoid any hazards.
- Prior to installation or electrical work, ensure that polyethylene bags are not left in the reach of children to avoid suffocation.
- Securely apply heat insulation to the refrigerant pipe to avoid condensation on the surface of pipes, ceiling, floor, or valuables.
- Use only specified electric wires with current capacity if electrical work is required to avoid electric leak, overheating, or fire.
- Complete drain piping work in accordance with the installation manual to avoid water leaks that may cause damage to the ceiling, furniture, and other items.
- Inspect and look for any missing or loose screws after the snowguards have been installed.
- Follow the below steps for installation:
- Install the SD LHS Panel & SD RHS Panel using the included (6) Truss Head Type `F’ Screws.
- Attach the SD Panel to the SD RHS Panel & SD LHS Panels using the provided holes and supplied #8 HWH screws.
- Tighten the 2 screws already installed on the SD Panel.
- Install provided Lanyards to cabinet chassis with the existing screws.
- Install Service Panel with the supplied #8 HWH screws to the SD Panel using the provided holes.
ALWAYS KEEP SAFETY IN MIND
- Read this section carefully [always keep safety in mind] and securely install the optional parts.
- Make sure to follow the precautions outlined below: They contain critical safety content.
- The classifications for danger and possible consequences of incorrect handling are shown in the following indications.
WARNING: IMPROPER HANDLING MAY CAUSE DEATH OR SERIOUS INJURY.
CAUTION: INJURY OR DAMAGE TO HOUSE AND HOUSEHOLD ARTICLES MAY RESULT FROM
IMPROPER HANDLING.
NOTE: After installation, run a test run to ensure that there are no
anomalies, and ask your customer to always keep this installation sheet with
the instruction manual. In addition, if the end user changes, request that
these manuals be transferred to the new user.
WARNING
INQUIRE WITH THE DEALER OR SPECIALIST ABOUT INSTALLATION
- Water leaks, electric shocks, fires, and other hazards may occur if the user installs the product incorrectly.
CAREFULLY INSTALL THE PANEL IN ACCORDANCE WITH THIS INSTALLATION SHEET
- Incorrect installation could result in a water leak, electric shock, or fire, among other things.
Prior to installation (moving) and electrical work
POLYETHYLENE BAGS SHOULD NOT BE LEFT IN THE REACH OF CHILDREN
- Putting a polyethylene bag over one’s head will close off your breathing pathways, potentially resulting in suffocation.
CAUTION
TO AVOID CONDENSATION, SECURELY APPLY HEAT INSULATION TO THE REFRIGERANT
PIPE
- Condensation on the surface of pipes, as well as dewdrops on the ceiling, floor, or valuables, might develop if heat insulation is insufficient.
USE ONLY SPECIFIED ELECTRIC WIRES WITH CURRENT CAPACITY IF ELECTRICAL WORK IS REQUIRED.
- Unsuitable wire may cause an electric leak, overheating, or fire.
SECURELY COMPLETE DRAIN PIPING WORK IN ACCORDANCE WITH THE INSTALLATION MANUAL TO AVOID CONDENSATION.
- If the piping work is incorrect, a water leak may occur, causing the ceiling, furniture, and other items to become wet.
When the outdoor unit fan enters low speed rotation mode with the fan controller turned on, this Snow Guard prevents reverse rotation. It is also used to protect the fan when strong winds, such as a typhoon or wind blowing through tall buildings, strike the air outlet directly. Furthermore, installation of this product is required when cooling operations are to be carried out in outside-air temperatures of -5°C or lower (down to -15°C).
When installing this product, pay special attention to the following:
- Install this unit with the back surface facing the wall side to eliminate the effects of external winds.
- This unit should not be installed in such a way that the wind blows directly at the back of the unit.
- The installation of this product will reduce the unit’s capacity by approximately 2% – 3% and increase the outdoor unit’s noise level by approximately 1dB – 2dB.
- Use this product only if there is no obstruction on either side or above the outdoor unit (discharge air will be blocked). This could result in a short cycle.
Parts Check :
Note: Check that the following items, along with this manual, are in this
box:
Installation Hardware| 1 x SD
LHS Panel| 1 x SD
Panel| 1 x SD
RHS Panel| 1 x SD
Service Panel
SPECIAL SCREW| | | | |
|
6 x #10-24 x ½” TRUSS HEAD TYPE ‘F’ SCREWS (STAINLESS)| 16 x #8 X 1/2” HWH
SELF TAPPING SCREWS (ZINC)
2 x Lanyard 16” (STAINLESS STEEL)
2 x #10-24 X ½” PAN COMB MACHINE SCREWS (ZINC)
2 x #10-24 HEX NUTS (ZINC)
8 x #10 WASHERS (ZINC)
SG-1-SD (SNOW GUARD)
INSTALLATION PROCEDURE
-
Install the SD LHS Panel & SD RHS Panel as shown using the included (6) Truss Head Type ‘F’ Screws.
-
Install the ½” Wide Anti-Vibration foam on to the exterior edges of the SD LHS Panel & SD RHS Panels.
-
With the supplied #8 HWH screws attach the SD Panel to the SD RHS Panel & SD LHS Panels using the provided holes.
-
Install Service Panel with the supplied #8 HWH screws to the SD Panel using the provided holes.
NOTE: Make sure to inspect and look for any missing or loose screws after the snow guards have been installed.