Good Earth Lighting FP1247-AL5-48LFW-G 2 ft x 2 ft LED Flat Panel Instruction Manual
- June 11, 2024
- Good Earth Lighting
Table of Contents
Good Earth Lighting FP1247-AL5-48LFW-G 2 ft x 2 ft LED Flat Panel
MOUNTING
Hardware kit*
Required
WARNING: SHUT OFF POWER AT THE CIRCUIT BREAKER OR FUSE PANEL BEFORE REMOVING THE OLD FIXTURE OR INSTALLING A NEW ONE.
WARNINGS AND CAUTIONS
SHUT OFF POWER AT THE CIRCUIT BREAKER OR FUSE PANEL BEFORE REMOVING THE OLD
FIXTURE OR INSTALLING A NEW ONE.
Read entire installation procedure before you begin and save instructions for
future reference.
THIS FIXTURE IS DIMMABLE USING THE GOOD EARTH LIGHTING APP. (INSTRUCTION
SHEETS INCLUDED)
If unsure if the electrical box is properly grounded, or the box is plastic
and has no ground wire, or are unfamiliar with the methods of properly
grounding fixture, consult a qualified electrician.
IMPORTANT SAFETY INFORMATION
- Do not look directly at LEDs for extended period of time.
- For INDOOR use only.
- Turn power off before servicing.
- Do not leave bare wires exposed.
- For electrical requirements, see fixture. Minimum 90°C supply conductors.
INSTALLATION
TURN POWER OFF AT BREAKER BOX/FUSE BOX. TURN WALL SWITCH TO JUNCTION BOX OFF
Remove mounting plate from LED panel by sliding into the direction of the
slots closest to the mounting screws (AA), and then lifting up. Hold the
mounting plate up to the junction box in the desired fixture mounting
orientation.
Pull black, white and ground supply wires from electrical box through the hole
in center of mounting plate. Ground wires can be either green or bare copper.
Attach mounting plate to the electrical box using mounting screws (AA)
provided.
2A Locate the open holes for mounting at the corners of the mounting
plate and drill 1/8 in. pilot hole in the center. If a wooden stud is
encountered, use the screws (BB) and washers (EE) provided to secure the
mounting plate directly to stud.
2B If no stud is encountered, place the drywall anchors (CC) in the pilot
holes and screw them into place until flushed with surface of drywall. Place
washer (EE) over the mounting hole and drive screws (BB) into drywall anchor
until snug.
DO NOT OVERTIGHTEN. NOTE: Main support for mounting plate is electrical
box when it is secured properly. If the electrical box is not properly
secured, alternative mounting methods such as toggle bolts (not included)
should be used to secure mounting plate
3 Hold fixture up to secured mounting plate and attach the two support
wire hooks from the backside and the one from the front side of fixture to the
specially designed slots in the mounting plate to temporarily hold fixture for
wiring
4 Hold fixture up to secured mounting plate and attach the two support
wire hooks from the backside and the one from the front side of fixture to the
specially designed slots in the mounting plate to temporarily hold fixture for
wiring.
Fixture must be properly grounded. Connect fixture ground wire to ground
wire in electrical box using a wire nut (DD). Ground wires can be either
green or bare copper.
Connect black supply lead to black fixture wire **L**
and white supply lead
to white fixture wire using **N**
wire nuts (DD). Secure the wire nuts
properly to prevent the wires from coming loose. Use cable ties (FF) to secure
loose fixture wires to one another in the center of the mounting plate to keep
them from getting in the way during fixture mounting. Push excess wire back
into the electrical box
5A Keeping the support wire hooks attached to the mounting plate, lift up
the LED panel, being careful not to scratch ceiling. Align and insert the 2
metal tabs (on the same side of the mounting plate as the support wires) into
the corresponding slots on the LED panel.
5B While keeping the first 2 metal tabs inserted, pivot the panel up and
insert the 2 remaining tabs on the opposite side.
5C Slide panel until tabs are locked into place. Note that the direction
will be either left or right, depending on panel orientation. Slowly release
fixture, making sure it stays in place.
6 Slowly release fixture, making sure it stays in place.
IMPORTANT: To lock the panel in place, insert plastic push-in fastener
(GG) into the predrilled holes on the side of the panel.
CARE AND MAINTENANCE: Periodically clean the fixture and diffuser using a
mild, non-abrasive cleaner and soft cloth. When cleaning the fixture, make
sure the power is turned off.
Do not spray cleaner directly onto any part of the fixture or LEDs.
Good Earth Lighting® – 10 YEAR LIMITED WARRANTY: The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period of (10) years from the date of original purchase by the consumer. The fixture is not warrantied for use in a commercial or retail application. The warranty is limited to use in a residential environment. We will repair or replace (at our option) the unit in the original color and style if available, or in a similar color and style if the original item has been discontinued, without charge. Defective units must be properly packed and returned to the manufacturer with a letter of explanation and your original purchase receipt showing date of purchase. Call 1-800-291-8838 to obtain a return authorization number and an address where to ship your defective product. Note: C.O.D. shipments will NOT be accepted. The liability of the manufacturer is in any case limited to replacement of the defective light fixture product. The manufacturer will not be liable for any other loss, damage, labor costs or injury which is caused by the product. This limitation upon the liability of the manufacturer includes any loss, damage, labor costs or injury which is (I) to person or property or otherwise; (II) incidental or consequential in nature; (III) based upon theories of warranty, contract, negligence, strict liability, tort, or otherwise; or (IV) directly, or indirectly related to the sale, use, or repair of the product. This warranty gives you specific rights, and you may also have other rights which vary from state to state
FCC STATEMENT: This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that the interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: 1) Reorient or relocate
the receiving antenna. 2) Increase the separation between the equipment and
receiver. 3) Connect the equipment into an outlet on a circuit different from
that of the receiver. 4) Consult the dealer or an experienced radio/TV
technician for help.
Before doing any work on the fixture, shut off power supply at the circuit breaker panel to avoid electrical shock.
TROUBLESHOOTING GUIDE
PROBLEM | POSSIBLE CAUSE | CORRECTIVE ACTION |
---|---|---|
Light does not come on. |
- Power/ light switch is off.
- Fixture not properly wired to junction box.
- Bad switch
|
- Verify power supply and light switch are on.
- Check wiring connections.
- Test or replace switch
Fuse blows or circuit breaker trips when light is turned on| Discontinue use.|
- Call customer service (1-800-291-8838).
REPLACEMENT PARTS LIST
Hardware Kit: ZH-FP1247-F01-AL5
Please visit our website at: https://goodearthlighting.com/contact-us or call the Customer Care Center 1-800-291-8838, 8:30 a.m.-5 p.m., CST, Monday-Friday.
Good Earth Lighting® 1400 East Business Center Drive, Ste. 108 Mount
Prospect, IL 60056
Good Earth Lighting® is a registered trademark of Good Earth Lighting,
Inc. © 2021 Good Earth Lighting, Inc.