Carrier DLFPHB Ductless Unit Split System Owner’s Manual
- June 11, 2024
- Carrier
Table of Contents
DLFPHB
Owner’s Manual
Ductless Unit Split System – Sizes 09, 12 and 18
NOTE TO EQUIPMENT OWNER:
Please read this Owner’s Information Manual carefully before installing and
using this appliance and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new
equipment in the spaces provided. This information, along with the
installation data and dealer contact information, will be helpful should your
system require maintenance or service.
UNIT INFORMATION
Model #
Serial # ____
INSTALLATION INFORMATION
Date Installed
DEALERSHIP CONTACT INFORMATION
Company Name: __
Address:_____
Phone Number:____
Technician Name:__
A NOTE ABOUT SAFETY
Any time you see this symbol **** in manuals, instructions and on the unit, be aware of the potential for personal injury. There are 3 levels of precaution:
- DANGER identifies the most serious hazards which will result in severe personal injury or death.
- WARNING signifies hazards that could result in personal injury or death.
- CAUTION is used to identify unsafe practices which could result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
WARNING
PERSONAL INJURY, DEATH AND / OR PROPERTY DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Improper installation, adjustment, alteration, service, maintenance, or use
can cause explosion, fire, electrical shock, or other conditions which may
cause personal injury or property damage. Consult a qualified installer,
service agency, or your distributor or branch for information or assistance.
The qualified installer or service agency must use factory-authorized kits or
accessories when modifying this product.
Read and follow all instructions and warnings, including labels shipped with
or attached to unit before operating your new air conditioner.
GENERAL
The high wall fan coil unit provides quiet, maximum comfort. In addition to
cooling and/or heating, the high wall fan coil unit matched with an outdoor
condensing unit filters and dehumidifies the air in the room to provide
maximum comfort.
IMPORTANT: The high wall fan coil unit should be installed by authorized
personnel only; using approved tubing and accessories. If technical
assistance, service or repair is needed, contact the installer. The high wall
fan coil unit can be set up and operated from the remote control (provided).
If the remote is misplaced, the system can be operated from the “Auto” setting
on the unit.
Operating Modes
The high wall fan coil unit has five operating modes:
- FAN Only
- AUTO
- HEATING (heat pumps only)
- COOLING
- DEHUMIDIFICATION
FAN Only
In the FAN Only mode, the system filters and circulates the room air without
changing room air temperature.
AUTO
In the AUTO mode, the system automatically cools or heats the room according
to the user-selected set point.
NOTE: AUTO mode is recommended for use on single zone applications ONLY.
Using AUTO CHANGEOVER on multi-zone applications could set an indoor unit to
STANDBY mode, indicated with two dashes (–) on the display, which will turn
off the indoor unit until all the indoor units are in the same mode (COOLING
or
HEATING). HEATING is the system’s priority mode.
Simultaneous HEATING and COOLING is not allowed.
HEATING
In the HEATING mode, the system heats and filters the room air.
COOLING
In the COOLING mode, the system cools, dries and filters the room air.
DEHUMIDIFICATION (DRY)
In the DEHUMIDIFICATION mode, the system dries, filters and slightly cools the
room air temperature. This mode prioritizes air dehumidification but it does
not take the place of a dehumidifier. This feature cannot be used in a multi-
zone system.
Wireless Remote Control
The remote control transmits commands to set up and operate the system. The
control has a window display panel that displays the current system status.
The control can be secured to a surface when used with the mounting bracket
provided.
Wired Remote Control (Optional)
Refer to the Wired Controller manual.
24V Interface (Optional)
Allows the control of the Ductless System with a third party thermostat.
Smartphone Control (Optional)
Capability to be controlled by a smartphone adding the Wi-Fi® Interface Kit
KSAIF0601AAA (sold separately).
PART NAMES AND DISPLAY
NOTE: Different models have different front panels and display windows.
Not all the indicators described above are available for the air conditioner
you purchased. Check the indoor display window of the unit you purchased.
Illustrations in this manual are for reference purposes. The actual shape of
your indoor unit may differ slightly.
Fig. 1 —Indoor Unit
WIRELESS REMOTE CONTROL
Before you begin using your new air conditioner, familiarize yourself with the
remote control. See page 6 through page 10 for more information on these
controls.
Fig. 2 —Remote Control Functions
Model (9-12K): RG10P(2HS)/BGEF and RG10P(2HS)/BGEFU1(FRESH feature is not
available) RG10P1(2HS)/BGEF,RG10P1(2HS)/BGEFU1
Model (18K): RG10L(2HS)/BGEF and RG10L(2HS)/BGEFU1(FRESH feature is not
available) RG10L1(2HS)/BGEF,RG10L1(2HS)/BGEFU1
RG10L10(2HS)/BGEF(20-28 C/68-82 F)
WIRELESS REMOTE CONTROL LCD SCREEN INDICATORS
Information appears when the remote controller is on.
Fig. 3 —Wireless Remote Controller
Indicators
REMOTE CONTROL
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage.
IMPORTANT: The remote control can operate the unit from a distance of up
to 26 ft. (8 m) as long as there are no obstructions. When the timer function
is used, the remote control should be kept in the vicinity of the fan coil
(within 26 ft. / 8 m).
The remote control can perform the following basic functions:
- Turn the system ON and OFF
- Select the operating mode
- Adjust room air temperature set point and fan speed
- Adjust right-left airflow direction
Refer to the “WIRELESS REMOTE CONTROL” on page 4 for a detailed description of all the capabilities of the remote control.
Battery Installation
Two AAA 1.5v alkaline batteries (included) are required for remote control
operation.
To install or replace batteries:
- Slide the back cover off the control to open the battery compartment.
- Insert the batteries. Follow the polarity markings inside the battery compartment.
- Replace the battery compartment cover.
NOTES:
- When replacing batteries, do not use old batteries or a different type battery. This may cause the remote control to malfunction.
- If the remote is not going to be used for several weeks, remove the batteries. Otherwise, battery leakage may damage the remote control.
- The average battery life under normal use is about 6 months.
- Replace the batteries when there is no audible beep from the indoor unit or if the Transmission Indicator fails to light.
When batteries are removed, the remote control erases all presets (e.g.,
Follow Me). The presets must be restored after the insertion of new batteries.
BASIC REMOTE CONTROL OPERATION
Before operation, ensure the unit is plugged in and power is available.
COOL Mode A220205
Fig. 4 —COOL Mode
- Press MODE to select the COOL mode.
- Set your desired temperature using TEMP or TEMP
- Press FAN to select the fan speed in a range of AU‘100%,
- Press ON/OFF to start the unit.
Setting Temperature
The operating temperature range for units is 60-86°F (16-30°C)/(68-82 °F
(20-28°C) (depends on model). Users can increase or decrease the set
temperature in 1°F (0.5°C) increments.
HEAT Mode A220206
Fig. 5 —HEAT Mode
- Press MODE to select the HEAT mode.
- Set your desired temperature using TEMP ∧ or TEMP ∨.
- Press FAN to select the fan speed in the range of AU-100%.
NOTE: As the outdoor temperature drops, the performance of your unit’s
HEAT function may be affected. In such instances, we recommend using this air
conditioner in conjunction with other heating appliances.
AUTO Mode
In AUTO mode, the unit automatically selects the COOL, FAN, or HEAT operation
based on the set temperature. Fig. 6 —AUTO Mode
- Press MODE to select AUTO.
- Set your desired temperature using TEMP ∧ or TEMP V.
- Press ON/OFF to start the unit.
NOTE: FAN Speed can not be set in the AUTO mode.
DRY Mode Fig. 7 —DRY Mode
- Press MODE to select the DRY mode.
- Set your desired temperature using TEMP ∧ or TEMP ∨.
- Press ON/OFF to start the unit.
FAN Mode Fig. 8 —FAN Mode
- Press MODE to select the FAN mode.
- Press FAN to select the fan speed in the range of AU-100%.
- Press ON/OFF to start the unit.
Remote Control Operation – Quick Start
NOTE: When transmitting a command from the remote control to the unit, be
sure to point the control toward the right side of the unit. The unit confirms
receipt of a command by sounding an audible beep.
-
Turn the unit on by pushing ON/OFF.
NOTE: If there is a preference for °C rather than °F (default), press and hold the + and – temperature set point buttons together for approximately 3 seconds. -
Select the desired mode by pushing MODE. Fig. 9 —Modes
-
Select the temperature set point by pointing the control toward the unit and pressing the increase/decrease temperature set point buttons until the desired temperature appears on screen.
-
Press FAN to select the desired fan speed.
NOTE: If the unit is operating in DRY or AUTO mode, the fan speed will be
automatically set and cannot be adjusted.
Set the airflow direction. When the unit is turned on, the Up-Down airflow
louvers default to the cooling or heating position. The user can adjust the
horizontal Up-Down airflow louver position by pushing DIRECT or have
continuous louver movement by pressing SWING.
When the outside temperature is below 32°F (0°C), we strongly recommend
maintaining power on the unit to ensure smooth ongoing performance.
To optimize unit performance, perform the following:
- Keep doors and windows closed
- Limit energy usage by using TIMER ON and TIMER OFF functions.
- Do not block air inlets or outlets.
- Regularly inspect and clean air filters.
Set Function
Fig. 10 —Set Function
- Press SET to enter the FUNCTION setting.
- Press SET or TEMP or TEMP to select the desired function.
- When the selected symbol flashes on the display, press OK to confirm.
To cancel the selected function, perform the same steps.
Press SET to scroll through the operation functions as follows:
Fig. 11 — Functions
Breeze Away Function (some units):
This feature avoids direct air flow from blowing on the room’s occupants.
NOTE: This feature is available under COOL, FAN and DRY mode only.
Active Clean Function (some units):
The Active Clean Technology washes away dust, mold, and grease that may cause
odors when it adheres to the heat exchanger by automatically freezing and then
rapidly thawing the frost. When this function is turned on, the indoor unit
window displays “CL”, after 20 to 45 minutes, the unit turns off automatically
and cancels the CLEAN function.
FRESH Function (some units):
When the FRESH function is initiated, the Ionizer/Plasma Dust Collector
(depending on models) is energized and helps to remove pollen and impurities
from the air.
SLEEP Function :
The SLEEP function is used to decrease energy use while you sleep (and do not
need the same temperature settings to remain comfortable). This function can
only be activated via remote controller. For the detail, see SLEEP OPERATION
in the User’s Manual.
NOTE: The SLEEP function is not available in FAN or DRY mode.
FOLLOW ME Function :
The FOLLOW ME function enables the remote control to measure the temperature
at its current location and sends this signal to the air conditioner every 3
minutes. When using the AUTO, COOL or HEAT modes, measuring the ambient
temperature from the remote controller (instead from the indoor unit itself)
allows the air conditioner to optimize the temperature around the occupants to
ensure maximum comfort.
NOTE: Press and hold BOOST for seven seconds to start/stop the FOLLOW ME
MEMORY feature.
- IF the MEMORY feature is activated, “ON” appears on the display for 3 seconds.
- If the MEMORY feature stops, “OFF” appears on the display for 3 seconds.
NOTE: When the FOLLOW ME Memory feature is activated, it will not be
canceled by pressing ON/OFF, MODE or power failure to the indoor unit.
AP Function (some units):
Select the AP function to configure the wireless network. For some units, it
does not work by pressing SET. To enter the AP mode, continuously press LED
seven times for 10 seconds.
FREEZE Protection
With the unit in HEAT mode and the wireless remote pointed at the indoor unit,
press the down arrow until the setpoint is 60°F (16°C). Press the down arrow
two times within two seconds to activate the 46°F (8°C) heating function
(heating set back). The unit now operates at a set temperature of 46°F (8°C).
The indoor unit display shows FP. No icon appears on the remote control.
NOTE: This function is only available in the heating mode.
Under this function, the unit heats at high fan speed until the space
temperature is 46°F (8°C). This mode can also be deactivated by pressing
ON/OFF, SLEEP, MODE, FAN, or either TEMP arrow.
FEATURES
The unit provides the following features for added comport and safety.
Time Delay
If ON/OFF is pressed too soon after a stop, the compressor will not start for
3 to 4 minutes due to the inherent protection against frequent compressor
cycling. The unit only emits an audible beep when the signals are received
correctly.
Heating
If the unit is in HEATING mode, there is a delay when the fan starts. The fan
starts only after the coil is warmed up to prevent cold blow.
Auto Defrost Operation
In the HEATING mode, if the outdoor coil is frosted, the indoor fan and
outdoor fan turns off while the system removes the frost on the outdoor coil.
The system automatically reverts to normal operation when frost is removed
from the outdoor unit.
Auto Start
If the power fails while the unit is operating, the unit stores the operating
condition, and it will start operation automatically under those conditions
when the power is restored.
Auto-Restart (some units)
If the unit loses power, it automatically restarts with the prior settings
once power has been restored.
Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air
conditioner continues to operate at very low power to dry up any condensed
water and prevent mildew growth.
Wireless Control (some units)
Wireless control allows users to control the air conditioner using a mobile
phone and a wireless connection. For the USB device access, replacement,
maintenance operations must be carried out by professional staff.
Louver Angle Memory (some units)
When turning on the unit, the louver automatically resumes its former angle.
Breeze Away (some units)
This feature avoids direct air flow from blowing on inhabitants.
Refrigerant Leak Detection (some units)
The indoor unit automatically displays EL0C when it detects refrigerant
leakage.
Occupancy Sensor
The system is controlled intelligently under the Occupancy Sensor mode. The
feature detects the movement in the room. In COOLING mode, when occupants are
away for 30 minutes, the unit automatically lowers the frequency to save
energy (for Inverter models only). And the unit automatically starts and
resumes operation when movement is
detected. This feature cannot be used in a multi-zone system.
Resetting the Remote Control
If the batteries in the remote control are removed, the current settings
cancel and the control returns to the initial settings and enters the STANDBY
mode. Push ON/OFF to activate.
NOTE: For multi-zone air conditioners, the following functions are not
available: ACTIVE CLEAN, SILENCE, BREEZE AWAY, REFRIGERANT LEAKAGE DETECTION
and ECO.
Setting Vertical Angle of Air Flow
While the unit is on, press SWING on the remote control to initiate the
horizontal louver AUTO SWING feature.
NOTE: When using the COOL or DRY mode, do not set the louver at too high
of an angle for long periods of time. Doing so can cause water to condense on
the louver blade, which may drop on your floor or furnishings. When using the
COOL or HEAT mode, setting the louver at too high of an angle can reduce the
performance of the unit due to restricted air flow.
Setting Horizontal Angle of Air Flow
When the unit is on, press and hold SWING for 2 seconds on the remote control
to initiate the vertical louver auto swing feature to control the horizontal
angle of the airflow.
ECO/Gear Function
Used to enter the ENERGY EFFICIENT mode and is only available in the COOLING
mode. When in COOLING mode, press ECO/GEAR, the remote controller will
maintain the temperature automatically between 75°F and 86°F, and set the fan
speed to Auto. Operation time in the ECO mode is 8 hours. After 8 hours, or if
a conflicting setting is engaged, the air conditioner exits this mode.
Gear operation is engaged by cycling through the ECO/GEAR operations. After
ECO, there is a setting for up to 75% and 50% of the unit’s electrical
consumption. The last step in the cycle is the previous unit setting before
ECO setting is engaged again and the cycle starts over.
SILENCE Function
Press FAN for more than 2 seconds to activate/disable the SILENCE function
(some units). Due to the compressor’s low frequency operation, it may result
in insufficient cooling and heating capacity. Press ON/OFF, MODE, SLEEP, TURBO
or CLEAN while operating to cancel the SILENCE function. Fig. 12 —Silence
Function
LOCK Function
Fig. 13 —Lock Function
Press BOOST and HUMIDITY together at the same time more than 5 seconds to
activate the LOCK function.
NOTE: The buttons will not respond unless the user press these two
buttons for two seconds again to disable the lock.
BOOST Function
Fig. 14 —Boost
When the user selects BOOST feature in the COOL mode, the unit blows cool
air with the strongest wind setting to jump-start the cooling process. When
users select BOOST in the HEAT mode (for units with Electric heat elements)
the electric heater activates and jump-starts the heating process.
Manual Operation (without remote control)
The manual button is intended for testing purposes and emergency operation
only.
NOTE: DO NOT use this function unless the remote control is lost and it
is absolutely necessary.
To restore regular operation, use the remote control to activate the unit.
The unit must be turned off before manual operation.
Use the following steps to operate the unit manually:
- Locate the MANUAL CONTROL button on the right-hand side panel of the unit.
- Press MANUAL CONTROL one time to activate FORCED AUTO mode.
- Press MANUAL CONTROL again to activate the FORCED COOLING mode.
- Press MANUAL CONTROL a third time to turn the unit off.
Fig. 15 —Range
NOTE: DO NOT move louver by hand. Doing so takes the louver out of sync.
Should this occur, turn off the unit and unplug it for a few seconds, then
restart the unit. Doing so resets the louver.
CAUTION
DO NOT put your fingers in or near the blower and suction unit side of the
unit. The high-speed fan inside the unit may cause injury.
Fig. 16 —Manual Control Button
**CLEANING, MAINTENANCE AND TROUBLESHOOTING (18K)
**
CAUTION
ELECTRICAL SHOCK HAZARD
Failure to follow this caution may result in personal injury or death.
Always turn off power to the system before performing any cleaning or
maintenance to the system. Turn off the outdoor disconnect switch located near
outdoor unit.
Be sure to disconnect the indoor unit if on a separate switch.
CAUTION
EQUIPMENT DAMAGE/OPERATION HAZARD
Failure to follow this caution may result in equipment damage or improper unit
operation.
Operating the system with dirty air filters may damage the indoor unit and
could cause reduced cooling performance, intermittent system operation, frost
build-up on indoor coil or blown fuses.
Periodic Maintenance
Periodic maintenance is recommended to ensure proper operation of the unit.
Recommended maintenance intervals may vary depending on the installation
environment, e.g., dusty zones, etc. Refer to Table 1 on page 14.
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury. The coil fins
are very sharp. Use caution when cleaning.
Cleaning the Coil
Clean the coil at the beginning of each cooling season, or when necessary.
Use a vacuum cleaner or a long-bristle brush to avoid damage to the coil fins.
Cleaning Air Filters (9K-12K)
Remove and clean the air filters once a month. A clogged air conditioner
can reduce the cooling efficiency of your unit, and can also be bad for your
health.
NOTE: If air filters show signs of excessive wear or are torn, they must
be replaced. Contact your local dealer for replacement filters.
- Lift the front panel of the indoor unit.
- Press the tab on the end of filter to loosen the buckle, lift it up, then pull it towards you.
- Pull the filter out.
- If your filter has a small air freshening filter, un-clip it from the larger filter. Clean the air freshening filter with a hand-held vacuum.
- Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
- Rinse the filter with fresh water, then shake off excess water.
- Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
- When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
- Close the front panel of the indoor unit.
Fig. 17 — Clean the filter
Cleaning Air Filters (18K)
Remove and clean the air filters once a month. A clogged air conditioner can
reduce the cooling efficiency of your unit, and can also be bad for your
health.
NOTE: If air filters show signs of excessive wear or are torn, they must
be replaced. Contact your local dealer for replacement filters.
- The air filter is on the top of the air conditioner.
- Hold both side of the top filter in the place marked with PULL, thenpull it upwards.
- If the filter has small air freshening filters, unclip them from the larger filter. Clean these air freshening filters with a hand-held vacuum.
- Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
- Rinse the filter with fresh water, then shake off any excess water.
- Dry the filter in a cool, dry place, and refrain from exposing it to direct sunlight.
- When dry, re-clip the air freshening filter to the larger filter, then install it back on the indoor unit.
**Fig. 18 —Hold and Pull the filter![Carrier DLFPHB Ductless Unit Split System
-
fig 16](https://manuals.plus/wp-content/uploads/2023/05/Carrier-DLFPHB- Ductless-Unit-Split-System-fig-16.png) CAUTION
Before changing the filter or cleaning, turn off the unit and disconnect its power supply.
When removing the filter, do not touch metal parts in the unit. The sharp metal edges can cut you.
Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause an electrical shock.
Do not expose filter to direct sunlight when drying. This can shrink the filter.
Cleaning the Indoor Unit Front Panel
To clean the front panel of the indoor unit, wipe the outside with a soft, dry cloth.
Pre-Season Inspection
After long periods of non-use, or before periods of frequent use, perform the following steps: Preparing for Extended Shutdown Period
Clean the filters and reposition them in the unit. Operate the unit in FAN ONLY mode for 12 hours to dry all internal parts. Turn the main power supply off and remove the batteries from the remote control. System Operation Recommendations**
The items outlined in the following list help to assure proper system operation:- Replace both remote control batteries at the same time.
- Point the remote control toward the unit display panel when transmitting a command.
- Keep doors and windows closed while unit is operating.
- Contact an authorized service representative if a problem arises that cannot be easily resolved.
- Do not perform cleaning or maintenance activities while the unit is on.
- Keep the display panel on the unit away from direct sunlight and heat as this may interfere with remote control transmissions.
- Do not block air intakes and outlets on the indoor or outdoor units.
Energy Saving Recommendations
The following recommendations will add greater efficiency to the ductless
system:
- Select a comfortable thermostat setting and leave it at chosen setting. Avoid continually raising and lowering the setting.
- Keep the filter clean. Frequent cleaning may be necessary depending on indoor air quality.
- Use drapes, curtains or shades to keep direct sunlight from heating the room on very hot days.
- Limit the unit’s run time by using the TIMER function.
- Do not obstruct the air intake on the front panel.
- Turn on the air conditioning unit before the indoor air becomes too uncomfortable.
TROUBLESHOOTING (CONT)
Refer to Table 1 before contacting your local dealer.
Table 1 — Periodic Maintenance
INDOOR UNIT | EVERY MONTH | EVERY 6 MONTHS | EVERY YEAR |
---|---|---|---|
Clean Air Filter’ | • | • | |
Replace Carbon Filter | • | • | |
Change Remote Control Batteries (as needed) | |||
OUTDOOR UNIT | EVERY MONTH | EVERY 6 MONTHS | EVERY YEAR |
Clean Outdoor Coil from Outside | • | ||
Clean Outdoor Coil from Insidet | • | ||
Blow Air Over Electric Partst | • | ||
Check Electric Connection Tighteningt | • | ||
Clean Fan Wheelt | • | ||
Check Fan Tighteningt | • | ||
Clean Drain Panst | • |
- Increase frequency in dusty zones.
† Maintenance to be carried out by qualified service personnel. Refer to the Installation Manual
The following problems are not a malfunction and in most situations will not require repairs.
Table 2 — Common Issues
ISSUE | POSSIBLE CAUSE |
---|---|
Unit does not turn on when pressing ON/ OFF | The unit has a 3-minute |
protection feature that prevents the unit from overloading. The unit cannot
restart within three minutes of being turned off.
The unit changes from COOL/HEAT mode to FAN mode| The unit may change its
setting to prevent frost from forming on the unit. Once the temperature
increases, the unit will start operating in the previously selected mode.
The set temperature has been reached, at which point the unit turns off the
compressor. The unit will continue operating once the temperature fluctuates
again.
The indoor unit emits white mist| In humid regions, a large temperature
difference between the room’s air and the conditioned air can cause white
mist.
Both the indoor and outdoor units emit white mist| When the unit restarts in
HEAT mode after defrosting, white mist may be emitted due to moisture
generated from the defrosting process.
The indoor unit makes noises| A rushing air sound may occur when the louver
resets its position.
A squeaking sound may occur after running the unit in HEAT mode due to
expansion and contraction of the unit’s plastic parts.
Both the indoor unit and outdoor unit make noises| Low hissing sound during
operation: This is normal and is caused by refrigerant gas flowing through
both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is
defrosting: This noise is normal and is caused by the refrigerant gas stopping
or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts
caused by temperature changes during operation can cause squeaking noises.
The outdoor unit makes noises| The unit makes different sounds based on its
current operating mode.
Dust is emitted from either the indoor or outdoor unit| The unit may
accumulate dust during extended periods of non-use, which will be emitted when
the unit is turned on. This can be mitigated by covering the unit during long
periods of inactivity.
The unit emits a bad odor| The unit may absorb odors from the environment
(such as furniture, cooking, cigarettes, etc.) which will be emitted during
operations.
The unit’s filters have become moldy and should be cleaned.
The outdoor unit fan does not operate| During operation, the fan speed is
controlled to optimize product operation.
Operation is erratic, unpredictable, or unit is unresponsive| Interference
from cell phone towers and remote boosters may cause the unit to malfunction.
In this case, try the following:
•Disconnect the power, then reconnect.
•Press ON/OFF on the remote control to restart the operation.
Table 3 — Troubleshooting
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
Unit/System Does Not Work | •The circuit breaker has tripped or a fuse has |
blown.
•Diagnostic lights illuminate.
•Voltage is too low.| •Reset the circuit breaker or replace the fuse with the
specified replacement fuse.
•Call your service representative.
•Call your service representative.
Cooling is Not Working Properly| •The filter is blocked by dust.
•Temperature is not set properly.
•A window or door is open.
•The outdoor unit is obstructed.
•The fan speed is too low.
•The operation mode is in Fan instead of Cool.| •Clean the air filter.
•Check the temperature and reset if necessary.
•Close the window or door.
•Remove the obstruction.
•Change the fan speed selection.
•Change the operating mode to Cool or reset the unit.
Heating is Not Working Properly| •The filter is blocked with dust.
•Temperature is set too low.
•A window or door is open.
•The outdoor unit is obstructed.| •Check the temperature and reset if
necessary.
•Close the window or door.
•Remove the obstruction.
Unit Stops During Operation| •The Off timer is not operating correctly.
•Diagnostic lights illuminate.| •Restart the operating mode.
•Call your service representative.
- Diagnostic lights are a combination of lights that will illuminate in the display area on the unit. They are a combination of the lights you see during normal operation.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
© 2022 Carrier. All rights reserved.
A Carrier Company
Edition Date: 03/22
Catalog No: DLFPHB-01OM
Replaces: New
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>