HYDREL HSL11 Static White and Static Color Instruction Manual

June 11, 2024
HYDREL

HYDREL-logo

HYDREL HSL11 Static White and Static Color

HYDREL-HSL11-Static-White-and-Static-Color-
product

Product Information

HSL11 Step Light

The HSL11 Step Light is a static white and static color step light with a ribbed design and matte black finish to reduce glare. It has an integral driver and an LED module with concealed optic. The light comes in three shapes: rectangle, round, and square. The dimensions of the rectangle shape are 4.60 x 2.50 inches, while the round and square shapes are 4.60 x 4.60 inches. The light is compatible with Steel City ‘CX’ series or equivalent back boxes (by others) and is suitable for concrete pour if the back box option is chosen or if Steel City back box is used. The HSL11 Step Light has three lumen packages: short (36 delivered lumens, 12 lumens/watt), medium (42 delivered lumens, 14 lumens/watt), and long (54 delivered lumens, 18 lumens/watt). The performance data is based upon 30K LED 80CRI.

The light is available in different ordering configurations, including shape (rectangle, round, or square), LED color temperature (2700K, 3000K, 3500K, 4000K, or 5000K), voltage (multi-volt 120V thru 277V), distribution (short, medium, or long throw), dimming optional (MIN5 dimming driver), and finish (brushed brass, brushed brass paint, brushed stainless steel, light bronze paint smooth, polished brass, polished stainless steel, semi-gloss black, semi-gloss white, custom finish, or RAL paint finishes).

Product Usage Instructions

Wiring and Dimming

Before installation, read all instructions carefully and do not make live connections. The HSL11 Step Light requires a 0-10V fluorescent-type dimming control for dimming installations. For non-dimming installations, cap off the grey and purple wires separately. To wire the light for non-dimming installations, connect the STEP WHITE wire to power NEUTRAL, the STEP BLACK wire to power HOT, and the STEP GREEN wire to power GROUND. The light is compatible with 120V or 277V power supply.

HIGHLIGHTS

  • Integral Driver
  • Short, Medium, and Long throw distributions
  • Standard 0-10V dimming option
  • Die-cast housing with solid aluminum, brass, or stainless steel faceplate
  • Wet location listed
  • Back Box provided by Hydrel or by others
  • Suitable for concrete pour if BB option is chosen or Steel City back box is used

DIMENSIONS

RECTANGLE

HYDREL-HSL11-Static-White-and-Static-Color-fig-1

ROUND

HYDREL-HSL11-Static-White-and-Static-Color-fig-2

SQUARE

HYDREL-HSL11-Static-White-and-Static-Color-fig-3

LUMEN PACKAGES

Distribution| Delivered Lumens| Input Watts| Lumens/ Watt
---|---|---|---
Short| 36| 3| 12
Medium| 42| 3| 14
Long| 54| 3| 18

  • Performance data based upon 30K LED 80CRI.

ORDERING INFORMATION

EXAMPLE: HSL11 SQ LED 27K MVOLT L MIN5 BRB

 |  |  |  |  |
---|---|---|---|---|---
Series                         Shape                      Source Color Temperature                                                 Voltage Distribution
HSL11 Step Light 11| RECT Rectangle

RD Round

SQ Square

| LED| 27K 2700K

30K 3000K

35K 3500K

40K 4000K

50K 5000K

| AMBLW Amber Limited

Wavelength 590 nm

BLU Blue

GRN Green

RED Red

CYN Cyan

RDO Red-Orange

| MVOLT Multi-Volt 120V

thru 277V

| L Long Throw

M Medium Throw

S Short Throw

Dimming Optional OPTION **Finish***
MIN5 Dimming Driver BB Back Box BRB Brushed Brass
    Note

Include BB if you need a back box, otherwise back box is by others.

| BBP Brushed Brass Paint

BRSS Brushed Stainless Steel

LBPS Light Bronze Paint Smooth

 |  |  | PBR Polished Brass
 |  | Note

Suitable for concrete pour if BB option is chosen or Steel City back box is used

| PSS Polished Stainless Steel

SGB Semi Gloss Black

SGW Semi Gloss White

 |  |  | CF Custom Finish
 |  |  | RALTBD Ral Paint Finishes
 |  |  | Note: RALTBD for pricing only, replace with applicable RAL call out when ready to order. See the RALBROCHURE for available options. It is recommended that Hydrel products only use textured paint.

Note: is a required field.

PERFORMANCE DATA

HYDREL-HSL11-Static-White-and-Static-Color-fig-5

  • Expected Life: Static White LED: L70 @ 60,000 hours
    • Static Color LED: L70 @ 60,000 hours
  • OPERATING TEMPERATURE: -40°C through 45°C

Lumen Multiplier Table for CCT

CCT Multiplier
27K 0.888
30K 1.000
35K 1.031
40K 1.047
50K 1.056

BUG RATING CHART

SERIES CCT Distribution BUG Rating
HSL11 30K S Short Throw B0U0G0

Note: For full report see IES file.

WIRING & DIMMING

POWER SUPPLY / DIMMING

  • Dimming drivers require a 0-10V fluorescent-type dimming control.
  • Read all instructions before installation. Do not make live connections!

NON-DIMMING INSTALLATIONS (For non-dimming, cap off the grey and purple wires seperately)

HYDREL-HSL11-Static-White-and-Static-Color-fig-6

  • Connect STEP WHITE wire to power NEUTRAL.
  • Connect STEP BLACK wire to power HOT.
  • Connect STEP GREEN wire to power GROUND.

DIMMING INSTALLATIONS

HYDREL-HSL11-Static-White-and-Static-Color-fig-7

  • The integral dimming driver is designed to the 0-10V IEC dimming specification 60929 and is compatible with common 0-10V dimmers and dimming systems.
  • Do NOT connect line voltage to dimming input wires.
  • Connect STEP WHITE wire to power NEUTRAL.
  • Connect STEP BLACK wire to power HOT.
  • Connect STEP VIOLET wire to POSITIVE INPUT of Dimming Control.
  • Connect STEP GREY or PINK wire to NEGATIVE INPUT of Dimming Control.

SPECIFICATIONS & FEATURES

Construction

  • Die-cast housing with solid aluminum, brass, or stainless steel faceplate. Two visible fasteners.

Source

  • Light source is a single powerful LED available in five static white color temperatures/80CRI & six colored LED choices. All within 3MacAdam ellipse

Optics

  • Concealed optic is available in three light distribution patterns. Short for narrow corridors, Medium for wide corridors, and Long for large area illumination.

Electrical

Integral electronic driver for 120 through 277v/50-60Hz input. Standard 0-10V dimming to 5%. THD: <20%. PFC: > 0.90. Complies to FCC CFR Title 47 Part 15, Class B at 120v and Class A at 277v EMI noise rating.

Mounting

  • Fixture designed to mount to a Steel City CX single gang deep junction box (BB option from Hydrel or by others) or equivalent.

Lens

  • Extruded clear acrylic optic lens concealed in reflector housing.

Circuiting

  • Single circuit

Environment

  • Wet location.

BUY AMERICAN ACT: This product is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT regulations. Please refer to www.acuitybrands.com/resources/buy- american for additional information.

Listing

  • ETL / cETL

Finish

Recessed surfaces have a ribbed design with matte black finish to reduce glare. Faceplates are available in four metal finishes with protective clear coat or one of four polyester powder coat painted finishes.

Warranty

5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and- conditions

NOTE: Actual performance may differ as a result of end-user environment and application.

  • All values are design or typical values, measured under laboratory conditions at 25 °C.
  • Specifications subject to change without notice.

© 2015-2023 Acuity Brands Lighting, Inc.

Contact

  • One Lithonia Way Conyers GA 30012
  • Phone: 800-705-SERV (7378)
  • www.hydrel.com