READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, Servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved.
- Regular fixture maintenance programs are recommended. It will occasionally be necessary to clean the outside of the refractor/lens.
- Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user.
- Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gOV
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wining connections should be capped with UL approved recognized wire connectors.
CAUTION
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION
- Keep combustibte and other materiats that cam burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE.
Any dimension on this sheet is to be assumed as a reference dimension: “Used
for information purposes only. It does not govern manufacturing or inspection
requirements.” (ANSI Y14.5-1973)
CAUTION: RISK OF PRODUCT
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifications deem otherwise:
- Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices.
- LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem othervwise: Do not exceed fixtures maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures.
- Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the tixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Please see product specific installation instructions for additional
warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
- Indoor/Outdoor
- Lithonia Lighting
- Carandini
- Holophane
- RELOC
- Indoor Lighting
- Gotham
- Mark Architectural Lighting
- Peerless
- Renaissance Lighting
- Winona Lighting
- Outdoor Lighting
- American Electric Lighting
- Antique Street Lamps
- Hydrel
- Tersen
- Controls
- Dark to Light
- Lighting Control & Design
- ROAM
- Sensor Switch
- Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out
of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203 2019 Acuity Brands Lighting, Inc.
All rights reserved. 07/31/19
INSTALLATION INSTRUCTIONS
Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes.
Hydrel fixtures are designed to meet 1990 National Electric Code, Article 680 requirements. The N.E.C. requires that fixtures must be installed so that the fixture lens is at least 18′ below normal water level. The junction box shall be located at least 8′ above maximum water level, pool deck or ground, whichever is greater. The junction box shall be located not less than 4 feet from the perimeter of the pool, unless separated from the pool by a fence, wall or other per manent barrier. Junction boxes mounted above grade in the walk way around the pool shall be afforded additional protection by lo- cating them in such places as under a diving board, adjacent to fixed structures, etc. Check local codes to assure acceptance.
JUNCTION BOX AND FIXTURE INSTALLATION NICHE MOUNT
(FOUNTAINS ONLY)
©2007 Acuity Brands Lighting, Inc. Rev. 09/17/07 INS-UWL-3 Rev_0
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE.
Any dimension on this sheet is to be assumed as a reference dimension: “Used
for information purposes only. It does not govern manufacturing or inspection
requirements.” (ANSI Y14.5-1973)One Lithonia Way, Conyers, GA 30012 Phone:
1800.705.SERV (7378) |
www.hydrel.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>