HYDREL 4750L Linear LED Flood w DPI Box Instructions
- June 11, 2024
- HYDREL
Table of Contents
HYDREL 4750L Linear LED Flood w DPI Box Instructions
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
WARNING
RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
CAUTION
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2013 Acuity Brands Lighting, Inc. All rights reserved. 6/12/13
1 INTRODUCTION
1.1 System Overview
The 4750L Linear LED Flood is a performance LED luminaire for use in outdoor architectural lighting applications. It is listed to applicable U.S & Canadian safety standards by Canadian Standards Association. It is suitable for wet location installations and ambient temperatures up to 50°C.
The DPI Box by Winona is a “Data Power Integration” device used combine line voltage and DMX into a single control cable or conduit for use with Acuity Brands RGBW and TUWH luminaires. It is listed to both UL and ETL 1598 Standards and is suitable for wet location installations.
Both devices comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1.2 Technical Information Sources.
If additional questions arise relative to these luminaires that this document or your supplier cannot answer, please refer them to:
Architectural Technical Support Hydrel 888-834-5684 Press #5 for Hydrel
2 INSTALLATION
2.1 System Integration Diagrams
Note : Read all instructions before installation. This luminaire and DPI Box must be installed and wired to NEC and Local Codes by a qualified electrician.
Note : Install 4750L Luminaires utilizing fixture Installation Instructions.
Note : No luminaire should be installed between DMX Controller and any DPI Box.
Note : No more that four DPI boxes can be utilized between the DMX Controller and any luminaire. A pyramid type arrangement can be used with DPI Boxes serving as hubs.
2.2 Fixture Connection to DPI Box
The luminaire is pre-wired with a UL listed wet location cord. It is not necessary to access fixture housing or driver box to install or wire the luminaire.
2.2.1
For single fixture connection up to four luminaires can be
connected to a single DPI Box. For more than four fixtures multiple DPI Boxes
can be connected in series up to four DPI boxes. Utilizing the appropriate
water tight cable gland, cord seal, or conduit fitting, make luminaire
connection to DPI Box.
2.2.2
For continuous run fixture connection up to four fixture runs can be connected
to a single DPI Box. For more than four fixture runs multiple DPI Boxes can be
connected in series up to four DPI boxes. Utilizing the appropriate water
tight cable gland, cord seal, or conduit fitting, make luminaire connection to
DPI Box. For all continuous run applications the last fixture in the series
must be terminated with a 120 ohm resistor cap, Hydrel part number RR4750L.
Note : For the conduit connection option the preferred communication/data cable used to carry the DMX signal is a Belden 9829 cable.
2.3 DPI Electrical & DMX Connections
2.3.1
Make sure supply power is turned off before making any connections.
2.3.2
Make power and DMX data connections to DPI box by first removing the 4 screws
and cover of the DPI Box. Remove the package of Blank-Off plugs from the
inside of the DPI Box and retain for future use. Verify that tall conduit and
luminaire cable connections have been made using the appropriate water tight
fittings. Make all wiring connections per the DPI Box diagram and figure 5 and
6 below. Use supplied Blank-Off plugs to seal all unused conduit entrances to
the DPI Box.
Note : Line Voltage must be isolated to the primary side of the DPI Box assembly.
Note : Low Voltage data lines must be isolated to the secondary side of the DPI Box assembly
Contractor Resources – Check out helpful programs, tools, installation videos and more!
Visit the Hydrel web site at www.Acuitybrands.com
References
- Brands.com High End Domains
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>