Table of Contents
Specification Architectural Flood
(SAF) Series
Installation Guide
READ AND FOLLOW ALL SAFETYINSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTERINSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the luminaire label
information.
Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
All wiring connections should be capped with UL approved recognized wire
connectors.
WARNING
RISK OF BURN
Allow lamp/fixture to cool before handling. Do not touch enclosure or light
source.
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer’s warnings, recommendations and restrictions for:
driver type, burning position, mounting locations/ methods, replacement and
recycling.
CAUTION
Wear gloves and safety glasses at all times when removing luminaire from
carton, installing, servicing or performing maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION
Keep combustible and other materials that can burn, away from lamp/lens.
Do not operate in close proximity to persons, combustible materials or
substances affected by heat or drying.
CAUTION: RISK OF PRODUCT
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer
jacket or damage wire insulation.
Unless individual product specifications deem otherwise: Never connect an LED
product directly to a dimmer packs, occupancy sensors, timing devices, or
other related control devices. LED fixtures must be powered directly off a
switched circuit.
Unless individual product specifications deem otherwise: Do not restrict
fixture ventilation. Allow for some volume of airspace around fixture. Avoid
covering LED fixtures with insulation, foam, or other material that will
prevent convection or conduction cooling.
Unless individual product specifications deem otherwise: Do not exceed
fixtures maximum ambient temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before
installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding
equipment must be worn during all installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten
lamp life, or alter performance.
Some components inside the fixture may not be serviceable. In the unlikely
event your unit may require service, stop using the unit immediately and
contact an ABL representative for assistance.
Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visitwww.acuitybrands.com.
Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting
Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen
Controls
Dark to Light
Lighting Control & Design
ROAM
Sensor Switch
Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
©2020 Acuity Brands Lighting, Inc. All rights reserved. 07/27/20
1 INTRODUCTION
AWSC
Architectural Wall Splice Cover
1.1 Product Description
Material: Aluminum
Dimensions
Depth: 1.313 inches (33.4mm)
Diameter: 6 inches (152.4mm)
This wall mounting accessory is designed for single light fixture support suitable for architectural and landscape lighting applications.
1.2 Technical Information Sources
If additional questions arise relative to this mounting accessory that this document or your supplier cannot answer, please refer them to:
Architectural Technical Support - Hydrel 888-834-5684, Press #5 for Hydrel
2 INSTALLATION
Warning: Turn Off supply power prior to making any electrical connections.
-
Secure Mounting Plate to mounting surface using appropriate fastener(s). (Fasteners by others
-
Attach Splice Cover to Mounting Plate using provided fasteners.
-
Secure Luminaire to Fixture Mount: Ensure gasket is placed between the Luminaire’s bottom section and the Fixture Mount. Secure the Luminaire to the Fixture Mount using provided Backup Nut (Torque to 30 in-lb).
-
Route Luminaire wires to Junction Box and make all wiring connections.
-
Secure Luminaire & Fixture Mount to the Mounting Plate using provided fasteners (Torque to 25 in-lb).
-
Aim luminaire as desired.
-
Gasket
-
Backup Nut
-
Fixture Mount
-
Junction Box (by others)
-
Mounting Plate
-
Splice Cover
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE.
Any dimension on this sheet is to be assumed as a reference dimension: “Used
for information purposes only. It does not govern manufacturing or inspection
requirements.” (ANSI Y14.5-1973)
Specification Architectural Flood (SAF) Series | 08/10/20 | REV 1
©2020 Hydrel Rev.| One Lithonia Way. Conyers GA. 30012
Phone: 1 800.705.SERV (7378) | www.hydrel.com
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
- Hydrel | Architectural Outdoor Lighting | Acuity Brands
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>