MITSUBISHI ELECTRIC MSZ-GS06NA BTU Wall Mounted Unit Owner’s Manual

June 11, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC MSZ-GS06NA BTU Wall Mounted Unit Owner’s Manual
MITSUBISHI ELECTRIC MSZ-GS06NA BTU Wall Mounted Unit

GENERAL FEATURES

  • Slim wall-mounted indoor units provide zone comfort control
  • Dual Barrier Coating applied to the heat exchanger, vanes and fan to prevent hydrophilic and hydrophobic dirt build-up
  • Optional Microparticle Filter designed to capture PM2.5
  • The outdoor unit powers the indoor unit, and should a power outage occur,\ the system is automatically restarted when power returns
  • Quiet operation
  • Smart Set: recalls a preferred preset temperature setting at the touch of a button
  • Built-in backup/auxiliary heater control available
  • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto
  • Multiple control options available:
    • Back-lit screen handheld remote controller (provided with the unit)
    • kumo cloud® smart device app for remote access
    • Third-party interface options
    • Wired or wireless controllers

SPECIFICATIONS

Specifications System
Unit Type MSZ-GS06NA
Cooling Capacity1, 3 BTU/H
Heating Capacity2, 3 BTU/H
Electrical Voltage, Phase, Frequency
Guaranteed Voltage Range V AC
Voltage: Indoor – Outdoor, S1-S2 V AC
Voltage: Indoor – Outdoor, S2-S3 V DC
Short-circuit Current Rating [SCCR] kA
Indoor Unit MCA
Fan Motor Full Load Amperage A
Fan Motor Output W
Airflow Rate at Cooling, Dry CFM
Airflow Rate at Cooling, Wet CFM
Airflow Rate at Heating, Dry CFM
Sound Pressure Level [Cooling] dB[A]
Sound Pressure Level [Heating] dB[A]
Drain Pipe Size In. [mm]
Coating on Heat Exchanger Dual Barrier Coating
External Finish Color Munsell 1.0Y 9.2/0.2
Unit Dimensions W x D x H: In. [mm]

295]
Package Dimensions| W x D x H: In. [mm]| 33-1/2 x 12 x 14 [850 x 300 x 350]
Unit Weight| Lbs. [kg]| 23 [10.4]
Package Weight| Lbs. [kg]| 26 [11.5]
Refrigerant| Type| R410A
Piping| Gas Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 1/4 [6.35]

NOTES:
Conditions
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB

Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer Multi-zone Outdoor Unit Operational Performance.

INDOOR UNIT ACCESSORIES: MSZ-GS06NA

Control Interface BACnet® and Modbus® Interface □ PAC-UKPRC001-CN-1
CN24 Relay Kit □ CN24RELAY-KIT-CM3
IT Extender □ PAC-WHS01IE-E
kumo station® for kumo cloud® □ PAC-WHS01HC-E
System Control Interface □ MAC-334IF-E
Thermostat Interface □ PAC-US444CN-1
Thermostat Interface □ PAC-US445CN-1
USNAP Adapter □ PAC-WHS01UP-E
Wireless Interface for kumo cloud® □ PAC-USWHS002-WF-2
Remote Sensor Wired Remote Sensor □ M21EAA307
Wireless temperature and humitity sensor for kumo cloud® □ PAC-USWHS003-TH-1
Wired Remote Controller Deluxe Wired MA Remote Controller† □ PAR-40MAAU
Simple Ductless Wired Remote Controller □ PAC-SDW01RC-1
Simple MA Remote Controller† □ PAC-YT53CRAU-J
Touch MA Controller† □ PAR-CT01MAU-SB
Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller □ MHK2
Lockdown bracket for remote controller □ RCMKP1CB
Condensate Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended] □ X87-721

Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H| □ X86-003
Blue Diamond Alarm Extension Cable — 6.5 Ft.| □ C13-192
Blue Diamond MultiTank — collection tank for use with multiple pumps| □ C21-014
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Drain Pan Level Sensor/Control| □ SS610E
Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit| □ T18-016
Refco Condensate Pump (100-240 VAC)| □ GOBI-II
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Sauermann Condensate Pump| □ SI30-230
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ- MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| Anti-allergy Enzyme Filter| □ MAC-408FT-E
Microparticle (PM2.5) Filter| □ MAC-EMF515FT-E
Lineset| 15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube Insulation)| □ MLS143812T-15
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube Insulation)| □ MLS143812T-30
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube Insulation)| □ MLS143812T-50
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube Insulation)| □ MLS143812T-65

NOTES:
† Requires MAC-334IF-E

  • M-Series EZ FIT® Recessed Ceiling Cassette, Floor-mount and Wall-mount
    Allows indoor units to connect to an MA Controller:
    Deluxe MA Remote Controller
    Simple MA Controller
    Touch MA Controller

INDOOR UNIT DIMENSIONS: MSZ-GS06NA

Dimensions

Piping Insulation ø1 – 9/16 O.D
Liquid line ø1/4 19 – 11/16 (Flared connection ø1/4)
Gas line ø3/8 16 – 15/16(Flared connection: ø3/8 ( GS06/09/12NA ), ø1/2 (

GS15NA ))
Drain hose| Insulation ø1-1/8 O.D Connected part ø5/8 O.D

Specifications are subject to change without notice.
© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved..

FORM# MSZ-GS06NA-U1 – 202304

1340 Satellite Boulevard Suwanee, GA 30024
Toll Free: 800-433-4822 www.mehvac.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals