MITSUBISHI ELECTRIC MSZ-GS09NA 9000 BTU-H Wall-Mounted Indoor Unit Owner’s Manual

June 11, 2024
Mitsubishi Electric

Mitsubishi-LOGO

MITSUBISHI MSZ-GS09NA 9000 BTU-H Wall-Mounted Indoor Unit

MITSUBISHI-ELECTRIC-MSZ-GS09NA-9000-BTU-H-Wall-Mounted-Indoor-Unit-
PRODUCT

Product Information: MSZ-GS09NA 9,000 BTU/H Wall-Mounted Indoor Unit

The MSZ-GS09NA is a wall-mounted indoor unit that provides cooling and heating functions. It has a cooling capacity of 9,000 BTU/H and a heating capacity of 10,900 BTU/H. The electrical requirements for this unit are 208/230V AC and 187-253V DC. The unit operates at a sound level of 19-31 dB[A] and has a CFM range of 134-283. The unit weighs approximately 18.7-23.5 kg and its dimensions are 11-3/16 x 30-5/16 x 8-1/16 inches.

Specifications

  • Cooling Capacity: 9,000 BTU/H
  • Heating Capacity: 10,900 BTU/H
  • Electrical Requirements: 208/230V AC, 187-253V DC
  • Sound Level: 19-31 dB[A]
  • CFM Range: 134-283
  • Weight: Approximately 18.7-23.5 kg
  • Dimensions: 11-3/16 x 30-5/16 x 8-1/16 inches

Usage Instructions

  1. Install the wall-mounted indoor unit according to the instructions provided in the user manual.
  2. Connect the indoor unit to the Multi-zone Outdoor Unit using refrigerant piping.
  3. Connect the required accessories to the indoor unit, such as a remote controller and filter.
  4. Refer to the Multi-zone Outdoor Unit Operational Performance chart to determine the connected capacity based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.
  5. Use the wired or wireless remote controller to operate the indoor unit and set the desired temperature and fan speed.
  6. Regularly clean or replace the filter to maintain optimal performance of the indoor unit.

GENERAL FEATURES

  • Slim wall-mounted indoor units provide zone comfort control
  • Dual Barrier Coating is applied to the heat exchanger, vanes, and fan to prevent hydrophilic and hydrophobic dirt build-up
  • Optional Microparticle Filter designed to capture PM2.5
  • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns
  • Quiet operation
  • Smart Set: recalls a preferred preset temperature setting at the touch of a button
  • Built-in backup/auxiliary heater control available
  • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto
  • Multiple control options available:
    • Back-lit screen handheld remote controller (provided with the unit)
    • Kumo cloud® smart device app for remote access
    • Third-party interface options
    • Wired or wireless controllers

Specifications

Specifications System
Unit Type MSZ-GS09NA
Cooling Capacity1, 3 BTU/H
Heating Capacity2, 3 BTU/H

Electrical

| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 187 – 253
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5

Indoor Unit

| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.5
Fan Motor Output| W| 30
Airflow Rate at Cooling, Dry| CFM| 134–160–222–307–381
Airflow Rate at Cooling, Wet| CFM| 121–144–200–276–343
Airflow Rate at Heating, Dry| CFM| 134–160–222–307–390
Sound Pressure Level [Cooling]| dB[A]| 19–22–30–37–43
Sound Pressure Level [Heating]| dB[A]| 19–22–30–37–43
Drain Pipe Size| In. [mm]| 5/8 [15.88]
Coating on Heat Exchanger| Dual Barrier Coating
External Finish Color| Munsell 1.0Y 9.2/0.2
Unit Dimensions| W x D x H: In. [mm]| 31-7/16 x 9-1/8 x 11-5/8 [798 x 232 x 295]
Package Dimensions| W x D x H: In. [mm]| 33-1/2 x 12 x 14 [850 x 300 x 350]
Unit Weight| Lbs. [kg]| 23 [10.4]
Package Weight| Lbs. [kg]| 26 [11.5]
Refrigerant| Type| R410A

Piping

| Gas Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 1/4 [6.35]

NOTES:
Conditions

  • 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
  • 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
  • 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer to Multi-zone Outdoor Unit Operational Performance.

INDOOR UNIT ACCESSORIES: MSZ-GS09NA

Control Interface

| BACnet® and Modbus® Interface| □ PAC-UKPRC001-CN-1
---|---|---
CN24 Relay Kit| □ CN24RELAY-KIT-CM3
IT Extender| □ PAC-WHS01IE-E
kumo station® for kumo cloud®| □ PAC-WHS01HC-E
System Control Interface| □ MAC-334IF-E
Thermostat Interface| □ PAC-US444CN-1
Thermostat Interface| □ PAC-US445CN-1
USNAP Adapter| □ PAC-WHS01UP-E
Wireless Interface for kumo cloud®| □ PAC-USWHS002-WF-2

Remote Sensor

| Wired Remote Sensor| □ M21EAA307
Wireless temperature and humitity sensor for kumo cloud®| □ PAC-USWHS003-TH-1

Wired Remote Controller

| Deluxe Wired MA Remote Controller†| □ PAR-40MAAU
Simple Ductless Wired Remote Controller| □ PAC-SDW01RC-1
Simple MA Remote Controller†| □ PAC-YT53CRAU-J
Touch MA Controller†| □ PAR-CT01MAU-SB

Wireless Remote Controller

| kumo touch™ RedLINK™ Wireless Controller| □ MHK2
Lockdown bracket for remote controller| □ RCMKP1CB

Condensate

| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]| □| X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor| □| X87-835
Blue Diamond Alarm Extension Cable — 6.5 Ft.| □| C13-192
Blue Diamond MultiTank — collection tank for use with multiple pumps| □| C21-014
Blue Diamond Sensor Extension Cable — 15 Ft.| □| C13-103
Drain Pan Level Sensor/Control| □ SS610E
Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit| □| T18-016
Refco Condensate Pump (100-240 VAC)| □ GOBI-II
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Sauermann Condensate Pump| □| SI30-230

Disconnect Switch

| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ-MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W

Filter

| Anti-allergy Enzyme Filter| □ MAC-408FT-E
Microparticle (PM2.5) Filter| □ MAC-EMF515FT-E

NOTES:
Requires MAC-334IF-E

  • M-Series EZ FIT® Recessed Ceiling Cassette, Floor-mount and Wall-mount
    Allows indoor units to connect to an MA Controller:
    Deluxe MA Remote Controller
    Simple MA Controller
    Touch MA Controller

INDOOR UNIT DIMENSIONS: MSZ-GS09NA

Unit: inch

MITSUBISHI-ELECTRIC-MSZ-GS09NA-9000-BTU-H-Wall-Mounted-Indoor-Unit-
FIG-1

Piping Insulation ø1 – 9/16 O.D
Liquid line ø1/4 19 – 11/16 (Flared connection ø1/4)
Gas line ø3/8 16 – 15/16

(Flared connection: ø3/8 ( GS06/09/12NA ), ø1/2 ( GS15NA ))

Drain hose| Insulation ø1-1/8 O.D Connected part ø5/8 O.D

FORM# MSZ-GS09NA-U1 – 202 1340
Satellite Boulevard Suwanee, GA 30024
Toll-Free: 800-433-4822 www.mehvac.com
© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved

References