Schneider Electric EVP3MM 4G Cellular Modem Instructions

June 11, 2024
Schneider Electric

Schneider Electric EVP3MM 4G Cellular Modem

Schneider-Electric-EVP3MM-4G-Cellular-Modem-product

The EVlink – EVP3MM is a smart wallbox designed for electric vehicle charging. It is equipped with cellular antenna inputs, Wi-Fi/Bluetooth antenna input, micro SIM card slot, reset button, status LEDs, power supply connection, Ethernet LEDs, Ethernet port, and RS232 interface. The GPS feature should not be used.

product Mounting

The EVlink – EVP3MM can be mounted on a wall. For installation on a smart wallbox or parking unit, follow the instructions provided in the user manual.

product Connection

For connection, there are different options available for the EVlink – EVP3MM. Follow the instructions provided in the user manual based on your specific requirement.

product Commissioning

Before commissioning the EVlink – EVP3MM, ensure that you follow the safety procedures and wear suitable personal protective equipment. Wait for several minutes until the power LED, status LED and one of the three signal LEDs are on.

Modem Commissioning
To commission the modem, follow the below steps:

  1. Check that your PC is connected by Ethernet cable to the charging station and that the latter is powered up.
  2. Open the network properties menu on your PC.
  3. Click Connect to the local network.
  4. Click Properties.
  5. Open the properties of the Internet version 4 protocol (TCP/IP v4).

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

  • Turn off all power supplying the charging station before working on the charging station.
  • Use a Voltage Tester of appropriate rating.

Failure to follow these instructions will result in death or serious injury.

NOTICE

RISK OF RADIO INTERFERENCE

  • In operation, the modem may emit electromagnetic signals that can interfere with different embedded systems.
  • Do not use the modem in areas where the use of mobile communications is limited or prohibited.

Failure to follow these instructions can result in equipment damage.

Content

Schneider-Electric-EVP3MM-4G-Cellular-Modem-
fig-2

Description

Schneider-Electric-EVP3MM-4G-Cellular-Modem-fig-3

Cellular Antenna Inputs

CELL: Primary / AUX: Diversity


Wi-Fi/Bluetooth antenna input. (Not

available)

Micro SIM card slot
Reset button
Status LEDs
Power supply connection
Ethernet LEDs
Ethernet port
RS232 interface
GPS (Do not use)

Mounting

NOTICE
RISK OF DAMAGED EQUIPMENT
The modem must be used in the following conditions:

  • Temperature range: -40°C to +85°C.
  • Mounting in the EVlink charging station.

Failure to follow these instructions can result in equipment damage .Schneider-Electric-EVP3MM-4G-Cellular-Modem-fig-4

NOTE: Reboot the modem if you replace the SIM card (by switching off and on the modem power supply)

EVlink Smart Wallbox

Schneider-Electric-EVP3MM-4G-Cellular-Modem-fig-5

EVlink Parking

Schneider-Electric-EVP3MM-4G-Cellular-Modem-fig-7

Connection

Schneider-Electric-EVP3MM-4G-Cellular-Modem-fig-9Schneider-Electric-EVP3MM-4G-Cellular-Modem-fig-10

Commissioning

Check Power Supply

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH Wear suitable personal protective equipment (PPE) and comply with the safety procedures. Failure to follow these instructions will result in death or serious injury.Schneider-
Electric-EVP3MM-4G-Cellular-Modem-fig-11

  • Start-up time may take several minutes. Wait until the power led, status led and one of the three signal leds are on.Schneider-Electric-EVP3MM-4G-Cellular-Modem-fig-12

Modem commissioning

STEP                             ACTION

1| Check that your PC is connected by Ethernet cable to the charging station and that the latter is powered up.
---|---
2| Open the network properties menu on your PC.
3| Click “Connect to local network”.
4| Click “Properties”.
5| Open the properties of the Internet version 4 protocol (TCP/IP v4).






6

| ****

– Case 1 (By default) – Network without DHCP:

Set the static IP address properties as follows (note the settings before modifying so as to be able to return afterwards to the initial configuration):

•      IP address: 192.168.0.x (where x is a number between 241 and 249)

•      Subnet mask: 255.255.255.0

•      No default gateway

•      No DNS server

•      No proxy

– Case 2 Network with DHCP:

•      Select “Obtain an IP Address Automatically” the DHCP server will assign IP address automatically to your computer

Connection ID

  • Enter address: http://192.168.0.254
  • On connection you may get a warning message (example with Google Chrome)
  • Click on ”Advanced” button
  • Click on the link “Proceed to … “(see picture below)Schneider-Electric-EVP3MM-4G-Cellular-Modem-fig-13

Connection ID

  • Username: admin
  • Password: EVlink4EV!

Password change:

For security reason please change the password.

  • In Administration tab, select User Accounts
  • Select the user account admin

CAUTION: Never delete the account ComChargingStationSchneider-Electric-
EVP3MM-4G-Cellular-Modem-fig-15

Password change:

  • Select Change PasswordSchneider-Electric-EVP3MM-4G-Cellular-Modem-fig-16
  • Follow the instructionSchneider-Electric-EVP3MM-4G-Cellular-Modem-fig-17

APN configuration:

In Cellular tab select Cellular Configuration

Declaration of Conformity

Hereby, Schneider Electric Industries SAS, declares that the modem EVP3MM used in EVlink offer is in compliance with the essential requirements and other relevant provisions of RED Directive 2014/53/EU. Frequency bands in which the radio equipment operates:

  • 2G operating frequency:

    • GSM 900 (Tx 880-915 MHz (max 32.78 dBm EIRP),Rx 925-960 MHz
    • GSM 1800 (Tx 1710-1785MHz (max 29.97 dBm EIRP),Rx 1805-1880MHz
  • 3G operating frequency:

    • WCDMA BAND I (Tx 1920-1980MHz (max 23.71 dBm),Rx 2110-2170MHz)
    • WCDMA BAND VIII (Tx 880-915 MHz (max 23.45 dBm),Rx 925-960MHz)
  • 4G operating frequency:

    • LTE FDD Band 1 (Tx 1920-1980MHz(max 23.5dBm), Rx 2110-2170MHz)
    • LTE FDD Band 3 (Tx 1710-1785MHz(max 23.7dBm), Rx 1805-1880MHz)
    • LTE FDD Band 7 (Tx 2500-2570MHz(max 23.8dBm), Rx 2620-2690MHz)
    • LTE FDD Band 8 (Tx 880-915MHz(max 23.6dBm), Rx 925-960MHz)
    • LTE FDD Band 20 (Tx 832-862MHz(max 23.8dBm), Rx 791-821MHz)
    • LTE FDD Band 28A (Tx 703-733MHz(max 24.32dBm), Rx 758-788MHz)
      The EU declaration of conformity for EVlink – EVP3MM device can be downloaded on www.se.com/doc:
  • EV20060301 EU declaration of conformity for EVlink – EVP3MM devices.

United Kingdom

UK Declaration of Conformity
Hereby, Schneider Electric Industries SAS, declares that the modem EVP3MM used in EVlink offer are in compliance with the essential requirements and other relevant provisions of Radio Equipment Regulations SI 2017 No. 1206. The UK declaration of conformity number EV20060301-UK can be downloaded on www.se.com/docs.
Frequency bands in which the radio equipment operates:

  • 2G operating frequency:
    • GSM 900 (Tx 880-915 MHz (max 32.78 dBm EIRP),Rx 925-960 MHz
    • GSM 1800 (Tx 1710-1785MHz (max 29.97 dBm EIRP),Rx 1805-1880MHz
  • 3G operating frequency:
    • WCDMA BAND I (Tx 1920-1980MHz (max 23.71 dBm),Rx 2110-2170MHz)
    • WCDMA BAND VIII (Tx 880-915 MHz (max 23.45 dBm),Rx 925-960MHz)
  • 4G operating frequency:
    • LTE FDD Band 1 (Tx 1920-1980MHz(max 23.5dBm), Rx 2110-2170MHz)
    • LTE FDD Band 3 (Tx 1710-1785MHz(max 23.7dBm), Rx 1805-1880MHz)
    • LTE FDD Band 7 (Tx 2500-2570MHz(max 23.8dBm), Rx 2620-2690MHz)
    • LTE FDD Band 8 (Tx 880-915MHz(max 23.6dBm), Rx 925-960MHz)
    • LTE FDD Band 20 (Tx 832-862MHz(max 23.8dBm), Rx 791-821MHz)
    • LTE FDD Band 28A (Tx 703-733MHz(max 24.32dBm), Rx 758-788MHz)

Troubleshooting

Schneider Electric Industries SAS

35, rue Joseph Monier CS 30323 F – 92506 Rueil Malmaison Cedex www.se.com NNZ2678201-06

  • 2023 Schneider Electric – All rights reserved.

Schneider Electric Limited Stafford Park 5 Telford TF3 3BL United Kingdom

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>